Ionomeric extracellular matrices for dynamic soft robotic tissue engineering devices through protein sulfonation
Matthew K. Burgess, Ryan T. Murray, Veronica M. Lucian, Zekun Liu, Robin O. Cleveland, Callum J. Beeston, Malavika Nair* · 2025
Read Ionomeric extracellular matrices for dynamic soft robotic tissue engineering devices through protein sulfonation by Matthew K. Burgess, Ryan T. Murray, Veronica M. Lucian, Zekun Liu, Robin O. Cleveland, Callum J. Beeston, Malavika Nair* (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-05302.txt.
Introduction
Matthew Burgess and co-authors present a new class of materials called ionomeric extracellular matrices for tissue engineering. Standard engineered tissues often rely on drugs to spur repair. Electric and mechanical signals can also help cells grow, yet today's electroactive polymers lack the biochemical cues of real tissue scaffolds.
The team attached taurine, a sulfonic acid biomolecule, to collagen, a natural matrix protein. The result is a material made fully from matrix matter that can actuate electromechanically, giving controlled electrical and mechanical stimulation while keeping native-like cell contacts. The authors frame it as a base for dynamic, soft robotic devices across many tissue engineering uses.
Catalog record
| CREATOR | Matthew K. Burgess, Ryan T. Murray, Veronica M. Lucian, Zekun Liu, Robin O. Cleveland, Callum J. Beeston, Malavika Nair* |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 50 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-05302
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Ionomeric extracellular matrices for dynamic soft robotic tissue engineering devices through protein sulfonation Matthew K. Burgess, Ryan T. Murray, Veronica M. Lucian, Zekun Liu, Robin O. Cleveland, Callum J. Beeston, Malavika Nair* Abstract Conventional tissue engineering methodologies frequently depend on pharmacological strategies to induce or expedite tissue repair. However, bioengineered strategies incorporating biophysical stimulation have emerged as promising alternatives. Electroactive materials facilitate the provision of controlled electrical, mechanical, and electromechanical stimuli, which support cell proliferation and tissue remodelling. Despite their ability to supply external electrical and mechanical stimuli to the tissue microenvironment, the electroactive polymers in use today often lack critical biochemical signals essential for native-like cell-cell and cell-scaffold interactions, thereby constraining their regenerative capabilities. To address the demand for biomimetic materials that possess enhanced capabilities in promoting cell and tissue stimulation, we present the development of a novel class of polymers called ionomeric extracellular matrices (iECMs). By utilising the linker-mediated conjugation of sulfonic acid biomolecules (taurine) to the backbone of an extracellular matrix protein (collagen), we illustrate the potential of iECMs as the first electromechanical actuating material platform derived entirely from ECM materials, paving the way for dynamic and soft-robotic platforms for a wide range of tissue engineering applications. Preprint: AIP/123-QED I Main The restoration of functional capabilities such as sensation and movement in damaged tissues remains a substantial challenge in the field of tissue engineering. The advancement of highly tissue-compatible materials and scaffold architectures has significantly enhanced the rate of repair, demonstrating the efficacy of static structures as platforms for regeneration [ 1 , 2 , 3 , 4 , 5 , 6 ] . Nevertheless, tissues are inherently dynamic, continually subjected to endogenous and exogenous physical and chemical stimuli that influence cellular processes [ 7 , 8 , 9 , 10 ] . While research efforts have predominantly concentrated on the utilisation of growth factors [ 11 , 12 , 13 ] and pharmaceutical agents [ 14 ] , electrical [ 15 , 16 , 17 ] , mechanical [ 18 , 19 , 20 ] , and electromechanical [ 21 , 22 , 23 ] stimulation have been established as efficacious therapeutic modalities. These methods expedite the healing process in skin [ 22 , 24 ] , nervous [ 25 ] , cardiac [ 26 , 27 ] , and muscular [ 3 , 20 ] tissues by guiding cellular processes such as migration, proliferation, differentiation, and apoptosis [ 7 , 28 ] . The effective conveyance of electrical and mechanical stimuli to cultured cells requires direct contact with the target tissue or stimulus transduction facilitated through an engineered construct. For the latter, electroactive polymers (EAPs), which are capable of delivering electromechanical stimulation or interpreting cellular signals, are being increasingly explored for their applications in skin, nerve, muscle, and cardiac regeneration, among others [ 29 , 30 , 31 , 32 ] . However, conventional electroactive materials exhibit poor biocompatibility, limited degradability, and often require operating conditions that fall outside of the physiological range [ 17 , 33 , 34 , 35 ] . These limitations constrain their utility in regenerative constructs, despite their potential for dynamic control. Some biomaterials exhibit intrinsic electroactivity (such as collagen and hydroxyapatite) through piezoelectricity; nonetheless, both the voltage output and the magnitude of actuation are insufficient for the development of controllable dynamic platforms [ 36 , 37 ] . To address this challenge, we present an ionic electrochemical actuator comprised exclusively of biologically-derived constituents, enabling ECM materials to be capable of electromechanical signal translation as a stimulation platform for dynamic tissue engineering. The conjugation of sulfonated biomolecule 2-aminoethanesulfonic acid (commonly called ‘taurine’) to collagen is achieved by employing common cross-linking agents. This side group modification of proteins with a low pKa functional group is hypothesised to facilitate the formation of an ionomers from the base ECM biopolymers. In this work, we show that the development of this net negative charged collagen ionic polymer results in an electromechanically active substrate capable of displacements comparable to those of commercial synthetic EAPs, and surpassing existing biological EAPs. The compatibility, degradation, and sensitivity of the material platform highlight the potential for ECM-derived actuators as a candidate for dynamic tissue engineering constructs. They offer advantages over the currently available ionic polymer actuators for controlled electromechanical stimulation of cells and tissues, promoting regeneration and repair. Our research establishes a novel framework by integrating the electromechanical capabilities of existing EAPs in an ECM-based platform to produce tissue-mimicking matrices. This innovation not only enhances the electromechanical performance but also precisely replicates the biochemical tissue microenvironment, facilitating advanced tissue engineering applications. II Concept overview and ionomeric extracellular matrix design Figure 1: a) Proposed EDC-NHS conjugation mechanism for functionalisation of collagen with a taurine. b) Distribution of the ionomeric extracellular matrix (iECM) consisting of a bound taurine anion linked to the tropocollagen helix in the presence of hydrated ‘free’ cations. c) Dynamic tissue engineering applications for ionomeric ECMs and the proposed mechanism of ionic actuation d) iECM resting position at 0 V and actuation path under 5 V DC over 180 seconds. Therapies based on electrical and mechanical stimulation have demonstrated considerable potential in the realm of tissue engineering, notably in peripheral nerve regeneration, angiogenesis, wound healing, cardiac tissue repair and skeletal muscle regeneration [ 22 , 24 , 38 , 39 ] . These applications often aim to address complications that lead to inflammatory stagnation in complex and chronic conditions, expediting recovery in nerve conduits [ 21 , 40 ] , and improved maturity in stem cell laden scaffolds prior to implantation [ 41 , 42 , 43 ] . However, the implementation of these therapies in the development of tissue engineering devices is constrained by the base materials, which frequently comprise synthetic, non-biodegradable, and cytotoxic EAPs. There exists a need for a resorbable and biocompatible EAP to effectively bridge the gap between the functional capabilities of synthetic ionic EAPs such as Nafion™ and Flemion™, while simultaneously possessing suitable biochemical characteristics that facilitate cellular integration and enable the resorption of the device through direct degradation and remodelling. To tackle these challenges, we have designed an entirely resorbable ionic-EAP, capable of electromechanical actuation, solely derived from ECM-based materials: an Ionomeric Extracellular Matrix (iECM). Our iECM is capable of inducing mechanical strain in response to an electrical stimuli due to the conjugation of the sulfonated biomolecule taurine to the tropocollagen helix. It is theorised that the free amine groups of taurine can form covalent amide bonds with the free carboxyl groups, typically found within the GXOGER sequence of collagen [ 44 ] , facilitated by chemical linkers such as EDC-NHS. This hypothesis is demonstrated in Fig. 1 a–b), which depicts taurine conjugation to the collagen backbone. When subject to an electric potential, the bound anions are attracted to the anode while the free cations in the hydrated substrate migrate towards the cathode, inducing an osmotic potential in the polymer membrane. The electro-osmotic pressure gradient in the iECM drives actuation in the membrane, inducing a strain on the surrounding cells and tissue through electrical and mechanical stimulation in a tissue-mimicking material (Fig. 1 c)). To assess the mechanical response under an applied field, we used a setup that applied a potential across