Influence of cellular mechano-calcium feedback in numerical models of cardiac electromechanics
Irena Radišić, Francesco Regazzoni, Michele Bucelli, Stefano Pagani, Luca Dede’, Alfio Quarteroni · 2025
Read Influence of cellular mechano-calcium feedback in numerical models of cardiac electromechanics by Irena Radišić, Francesco Regazzoni, Michele Bucelli, Stefano Pagani, Luca Dede’, Alfio Quarteroni (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-03447.txt.
Introduction
Irena Radisic and five co-authors weigh a missed link in heart models in a 2025 paper. Computer models of the heart join electric waves, calcium flow, and muscle squeeze to study the organ without surgery. To keep costs sane, models often skip the back-pull of stretch on calcium stores, though that pull is real.
The team built a fast frame that adds the back-pull at near no extra cost. They then joined it to full heart models in two known forms. Their runs show how much organ-level acts shift when the link is on. The work helps modelers pick which truths they can safely skip.
Catalog record
| CREATOR | Irena Radišić, Francesco Regazzoni, Michele Bucelli, Stefano Pagani, Luca Dede’, Alfio Quarteroni |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 82 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-03447
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Influence of cellular mechano-calcium feedback in numerical models of cardiac electromechanics Irena Radišić, Francesco Regazzoni, Michele Bucelli, Stefano Pagani, Luca Dede’, Alfio Quarteroni Abstract Multiphysics and multiscale mathematical models enable the non-invasive study of cardiac function. These models often rely on simplifying assumptions that neglect certain biophysical processes to balance fidelity and computational cost. In this work, we propose an eikonal-based framework that incorporates mechano-calcium feedback – the effect of mechanical deformation on calcium-troponin buffering – while introducing only negligible computational overhead. To assess the impact of mechano-calcium feedback at the organ level, we develop a bidirectionally coupled cellular electromechanical model and integrate it into two cardiac multiscale frameworks: a monodomain-driven model that accounts for geometric feedback on electrophysiology and the proposed eikonal-based approach, which instead neglects geometric feedback. By ensuring consistent cellular model calibration across all scenarios, we isolate the role of mechano-calcium feedback and systematically compare its effects against models without it. Our results indicate that, under baseline conditions, mechano-calcium feedback has minimal influence on overall cardiac function. However, its effects become more pronounced in altered force generation scenarios, such as inotropic modulation. Furthermore, we demonstrate that the eikonal-based framework, despite omitting other types of mechano-electric feedback, effectively captures the role of mechano-calcium feedback at significantly lower computational costs than the monodomain-driven model, reinforcing its utility in computational cardiology. Journal: Computer Methods in Applied Mechanics and Engineering 1 Introduction Mathematical models of cardiac electromechanics have increasingly gained biophysical detail making them a trustworthy tool in computational cardiology [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 ] , but their computational cost makes their use prohibitive if access to computing resources is limited [ 11 ] . Balancing the model’s biophysical accuracy with its computational efficiency becomes an increasingly challenging task as more detail is added to the mathematical model, calling for innovative formulations of the fully coupled problems [ 12 , 13 ] . Mathematical models of cardiac electromechanics aim at simulating the cardiac function by the coupling of both electrical and mechanical processes, namely electrophysiology and mechanics. Key mechanisms underlying cardiac electromechanical function are the excitation-contraction coupling [ 14 ] , which describes the onset of a substantial contractile force due to a sudden rise of intracellular calcium following an electrical signal, and the mechano-electric feedbacks [ 15 , 16 ] , a wide array of phenomena which describe the effect of mechanical alterations on cardiac electrophysiology and which under normal regimes provide a self-regulating mechanism for cardiac contraction, but whose dysfunction is implicated in arrhythmogenic effects [ 17 , 18 , 19 , 20 ] . While computer simulation has helped elucidate the role of the mechano-electric feedbacks on the cardiac function [ 20 , 21 , 22 ] , it is challenging to incorporate a large number of them consistently while understanding their differential effects. In this study we specifically focus on the impact of the mechano-calcium feedback (MCF) on the cardiac function. The MCF is a type of mechano-electric feedback which describes the effect of the sarcomere stretch on the calcium-troponin binding affinity [ 23 , 24 ] and, consequently, on calcium dynamics. This feedback has often been neglected in cardiac electromechanics modeling [ 25 , 20 ] , although recent works have incorporated the MCF in single-cell simulations [ 26 , 27 ] , providing physiological results for single-cell simulations and highlighting the importance of the feedback on inotropic risk assessment. Notwithstanding that the MCF is a cellular-level mechanism, a more realistic representation of its effects can only be ascertained through macroscopic tissue simulations, where dynamic and spatially heterogeneous tissue mechanical properties are present. There have been studies on the qualitative effects of the inclusion of the MCF in multiscale simulations [ 22 ] , however they have mainly focused on its consequences in terms of electrophysiological substrate heterogeneity. The principal drawback of using electromechanical models with respect to electrophysiology only, besides a more difficult interpretation of cause-effect relationships, is its high computational complexity that increases with the number mechano-electric feedback mechanisms that are included [ 28 , 29 ] . To deal with this complexity, suitable segregated-staggered solution schemes have been devised [ 30 , 25 ] , along with stabilization and interpolation techniques capable of dealing with sources of instability and loss of accuracy [ 31 , 32 , 33 ] . While these techniques make simulation feasible, their associated cost is non-negligible, and the incorporation of feedbacks remains computationally demanding. On the other hand, model formulations associated with lower computational costs needed to compute the numerical solutions, while possibly disregarding certain biophysical details, such as formulations based on the eikonal equation, remain a valid alternative [ 12 , 34 ] . However, it is important to understand the effects of what is being neglected, and, given a specific application in mind, to show that it has adequately small effects on the quantities of interest. In this work we study the impact of the inclusion of the mechano-calcium feedback in multiscale monodomain-driven cardiac electromechanics simulations by constructing bidirectionally coupled cellular electromechanical models, and for the first time, to the best of the our knowledge, we compare systematically their effects against models that do not account for the feedback starting from the same cellular baseline conditions. Moreover, we propose an alternative multiscale electromechanical framework based on the eikonal equation incorporating the mechano-calcium feedback. We show the eikonal-based framework to be a valid computationally efficient alternative even for biophysically detailed simulations, as exemplified by simulations on a realistic left ventricle geometry, both in baseline conditions and under variations of the cellular mechanical parameters. This work is structured as follows. In Section 2 we give an overview of mathematical models of cardiac electromechanics, we derive both single-cell and multiscale electromechanical models capable of capturing the MCF, and discuss their numerical implementation. In Section 3 we show the numerical results for the derived models. Finally, in Section 4 , we summarize the main contributions of this work and the implications for future cardiac electromechanics modeling and simulation. 2 Models and methods In this section we overview mathematical models of cardiac electromechanics, highlighting the modeling assumptions where relevant, and present the modeling contributions of this work. In Section 2.1 we derive a bidirectionally coupled and biophysically consistent cellular electromechanical model, capturing both the excitation-contraction coupling and the mechano-calcium feedback, and we generalize this procedure to a wider class of single calcium-buffer models. In Section 2.2 we present the fully coupled multiscale model of cardiac electromechanics employing the introduced cellular electromechanics model. In Section 2.3 we present a computationally efficient multiscale framework for eikonal-driven cardiac electromechanics incorporating the mechano-calcium feedback. Finally, in Section 2.4 , we propose a numerical scheme appropriate for the simulation of all the models previously introduced in the work. 2.1 Single-cell model derivation Let us consider a general cellular ionic model, represented by the following system of ordinary differential equations (ODEs): \displaystyle\derivative{\boldsymbol{w}}{t}=\boldsymbol{g}\left(u,\boldsymbol{w}\right),\hskip 7.5pt \displaystyle\mbox{in}\ (0,T], (1a) \displaystyle C_{\mathrm{m}}\derivative{u}{t}+\mathcal{I}_{\mathrm{ion}}\left(u,\boldsymbol{w}\right)=\mathcal{I}_{\mathrm{app}}(t),\hskip 7.5pt \displaystyle\mbox{in}\ (0,T], (1b) with suitable initial conditions, where \boldsymbol{w}=(\boldsymbol{w}_{\mathrm{G}},\boldsymbol{w}_{\mathrm{I}}) are the ionic variables consisting of the gating variables and ion concentrations, u is the transmembrane potential, \boldsymbol{w}_{\mathrm{G}}:[0,T]\mapsto\mathbb{R}^{n_{\boldsymbol{w}_{\mathrm{G}}}},\quad\boldsymbol{w}_{\mathrm{I}}:[0,T]\mapsto\mathbb{R}^{n_{\boldsymbol{w}_{\mathrm{I}}}},\quad u:[0,T]\mapsto\mathbb{R}, C_{\mathrm{m}} is the membrane