Space-Time Encoded Modulation for High-Fidelity Diffuse Optical Imaging

Ben Wiesel, Shlomi Arnon · 2025

Read Space-Time Encoded Modulation for High-Fidelity Diffuse Optical Imaging by Ben Wiesel, Shlomi Arnon (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-03246.txt.

Introduction

Ben Wiesel and Shlomi Arnon set out STEM, a new way to shape light so a single-pixel eye can build sharp images through a cloudy medium. Their paper is from two thousand twenty-five.

Imaging through such media gives prized facts, but sharp images have called for dense scans, which add error and time. In STEM, a laser lights the sample and one pixel reads the light that comes through. The image is split into tiles, each marked with its own near-unique code. The eye reads the sum of all tiles at once. Since the codes near not clash, each tile's strength can be pulled out. The team gives the math and lab proof, and matches it to plain scans.

Catalog record

CREATORBen Wiesel, Shlomi Arnon
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE47 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-03246

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Space-Time Encoded Modulation for High-Fidelity Diffuse Optical Imaging Ben Wiesel, Shlomi Arnon Abstract Diffuse optical imaging (DOI) offers valuable insights into scattering mediums, but the quest for high-resolution imaging often requires dense sampling strategies, leading to higher imaging errors and lengthy acquisition times. This work introduces Space-Time Encoded Modulation (STEM), a novel light modulation scheme enabling low-noise, high-resolution imaging with single-pixel detectors. In STEM, a laser illuminates the sample, and the transmitted light is detected using a single pixel detector. The detected image is partitioned into a two-dimensional array of sub-images, each encoded with a unique quasi-orthogonal code. These coded sub-images represent light transmission at specific locations along the sample boundary. A single-pixel detector then measures their combined transmission. By virtue of their quasi-orthogonality, the relative strength of each sub-image can be measured, enabling image formation. In this paper, we present a comprehensive mathematical description and experimental validation of the STEM method. Compared to traditional raster scanning, STEM significantly enhances imaging quality, reducing imaging errors by up to 60% and yielding a 3.5-fold increase in reconstruction contrast. 1 Introduction Looking through and inside turbid medium using visible, or near-infrared (NIR) light holds great significance across a wide range of scientific disciplines [1]. As light passes a scattering medium it undergoes multiple scattering events. Driven by its inherent stochastic nature, photons diverge from their original trajectories and follow a complicated random path, making image retrieval challenging [1]. One of the most promising techniques developed in this context is diffuse optical imaging (DOI) [1]–[3]. In DOI, an array of light sources illuminates the tissue, and the scattered light is measured with an array of detectors. Then, the reconstruction is done using model-based algorithms, where one attempts to “invert” a propagation model to image the object of interest [1]. DOI allows to image centimeters into objects with mm scale resolution and has been deployed in various potential applications such as breast [4] and brain imaging [5]. Despite DOI’s considerable achievements, its practical implementation encounters substantial hurdles. The fundamental reconstruction challenge it faces is inherently ill-posed and nonlinear, resulting in most algorithms producing low-resolution images riddled with noise and artifacts. Enhancing resolution and minimizing artifacts has therefore been the focus of prior investigations, highlighting the significance of increasing the amount of data extracted from the sample. This objective can be accomplished through the incorporation of either spectral [6], [7] or temporal [3], [8] data, and by implementing dense scanning strategies [6], [9][10], [11]. However, these approaches often require advanced single-pixel detectors and meticulous raster scanning, leading to extremely long acquisition and computational times, hindering their practical implementation in clinical settings. While methods that enable to acquire spatial information without compromising detection time are available, they typically incur significant cost and are limited in their achievable resolution [12], [13]. Single-pixel imaging emerges as a powerful solution, offering high-resolution images with high dynamic range at a fraction of the cost of traditional methods [14], [15]. Additionally, recent advancements in ultra-fast spatial light modulation [16], [17] open doors for developing novel imaging methods and stands as a pivotal component in our quest to push the boundaries of real-time diffuse imaging. This work introduces a novel single-pixel imaging approach, Space-Time Encoded Modulation (STEM), a novel light modulation scheme that leverages the capabilities of SLMs to achieve low-noise, high-resolution DOI imaging with single-pixel detectors. Unlike previous methods that utilized spatial modulation of light [14], [18], [19] our . method introduces temporal modulation for the first time. Which involves different families of modulation patterns to be used and novel image reconstruction algorithms to be developed. STEM draws inspiration from the principles of code division multiple access (CDMA) [20], [21] which enables multiple users to share a common channel by encoding their data with unique signature codes. By carefully designing the codes to have good correlation properties, the inter-user interference can be minimized, and each user’s signal can be accurately read [22], [23]. This same concept can be applied to diffuse imaging, where the primary goal is typically to measure the scattering of light with various detectors distributed throughout the sample. In the transmission configuration illustrated in Figure 1, this process entails illuminating the sample with a wide light source and capturing the transmitted light image using a single-pixel device. This involves several steps: First, the transmitted light is divided into a 2D array of sub-images, where each sub-image is being modulated by a unique signature code using a spatial light modulator (SLM). Subsequently, a single-pixel device records the combined intensity of all sub-images during their modulation period. Finally, to form an image, each sub-image’s allocated code is correlated with the detected signal to measure its relative intensity. This paper contributions can be summarized as follows: 1) The first application of temporally modulated light patterns with orthogonality in time for single-pixel imaging. 2) Development of a novel single-pixel imaging reconstruction algorithm based on temporal correlations. 3) Formulation of a comprehensive mathematical model enabling optimization of illumination patterns and a priori assessment of the modulation scheme effectiveness. 4) Introduction of a temporal compression technique which allows for reduced acquisition times while preserving most spatial information. Figure 1: Transmission configuration STEM: A wide laser source illuminates the sample, and the total transmitted light is measured using a single-pixel device. To form an image, the transmitted light is divided into a 2D array of sub images, each modulated with a unique signature code using an SLM. An image can be formed by correlating each sub image’s assigned code with the detected signal. Two primary noise mechanisms affect image quality: code interference and detector noise. 2 Methods 2.1 STEM in a nutshell The experimental setup (Figure 1) uses a continuous wave laser to illuminate a sample, to measure the spatially varying transmittance T via single-pixel detection. Here, T is a 2D image comprised of N unknown intensities T_{i} at pixel i ( N=N_{x}\cdot N_{y} ). A lens relays the transmittance image onto the SLM plane, where pixel-dependent binary signature codes modulate the light intensity. Finally, by focusing the light, a detector measures the combined intensity from all coded modulations. The signal at the output of the detector can be written as follows [24]: r(t)=\sum_{i=1}^{N}T_{i}P_{i}(t)+\delta r(t) (1) Where \delta r(t) is the detector noise and P_{i}(t) is the i -th pixel assigned signature code out of a code family C . An (n,w,\lambda_{m},\delta\lambda) signature code is a family of (0,1) sequences of length n , and weight w . The code weight w is the number of ones in the sequence and remains constant across all codes in C . The code size |C| is the number of sequences in the family. The codes are projected onto the SLM as binary on/off keys A_{i,j} in frames of duration T_{c} , given by [25]: P_{i}(t)=\sum_{j=0}^{n-1}A_{i,j}P_{T_{c}}(t-jT_{c}) (2) Where P_{T_{c}} is the rectangular pulse of duration T_{c} , and the total measurement time is denoted as T (i.e., T=n\cdot T_{c} ). The signature codes’ correlation definitions have undergone several changes compared to the traditional definitions used in multiple access applications [20], [21]. First, the constraint on the signature code’s autocorrelation is removed completely since we only deal with synchronous signals. Second, a new parameter is defined: the mean pairwise

Read the complete text