The role of spectator modes in the quantum-logic spectroscopy of single trapped molecular ions
Mikolaj Roguski, Aleksandr Shlykov, Ziv Meir, Stefan Willitsch · 2025
Read The role of spectator modes in the quantum-logic spectroscopy of single trapped molecular ions by Mikolaj Roguski, Aleksandr Shlykov, Ziv Meir, Stefan Willitsch (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-02642.txt.
Introduction
Mikolaj Roguski, Aleksandr Shlykov, Ziv Meir, and Stefan Willitsch wrote this paper in two thousand twenty-five. It studies the side modes of motion, called spectator modes, in quantum-logic spectroscopy of a single trapped molecular ion.
In this craft, the state of a target ion that lacks a handy light cycle is read through a partner ion, by way of shared motion. The authors find a Debye-Waller style effect by which the side modes bend the pair's reply to a state-tied force. Cooling those side modes lets the ground state of a nitrogen molecular ion be read with very high computed fidelity, in half the past time. Weak signals from several spin states can then be told apart at once.
Catalog record
| CREATOR | Mikolaj Roguski, Aleksandr Shlykov, Ziv Meir, Stefan Willitsch |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 49 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2504-02642
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The role of spectator modes in the quantum-logic spectroscopy of single trapped molecular ions Mikolaj Roguski, Aleksandr Shlykov, Ziv Meir, Stefan Willitsch Abstract Quantum-logic spectroscopy has become an increasingly important tool for the state detection and readout of trapped atomic and molecular ions which do not possess easily accessible closed-cycling optical transitions. In this approach, the internal state of the target ion is mapped onto a co-trapped auxiliary ion. This mapping is typically mediated by normal modes of motion of the two-ion Coulomb crystal in the trap. The present study investigates the role of spectator modes not directly involved in a measurement protocol relying on a state-dependent optical-dipole force. We identify a Debye-Waller-type effect that modifies the response of the two-ion string to the force. We show that cooling the spectator modes of the string allows for the detection of the rovibrational ground state of an N + 2 {}_{2}^{+} molecular ion with a computed statistical fidelity exceeding 99.99%, improving on previous experiments by more than an order of magnitude while also halving the experimental time. This enhanced sensitivity enables the simultaneous identification of multiple rotational states with markedly weaker signals. keywords trapped molecular ions, quantum logic spectroscopy, non-demolition state detection 1 Introduction Quantum-logic spectroscopy (QLS) protocols provide a framework for the readout of the internal state of a target (‘spectroscopy’) ion by mapping it onto the state of a co-trapped axillary (‘logic’) ion Schmidt et al. (2005) . This technique is usually employed for systems without readily accessible optical cycling transitions, e.g., atomic species such as Al + Schmidt et al. (2005) , highly-charged ions Micke et al. (2020) and molecular ions Wolf et al. (2016) ; Chou et al. (2017) ; Sinhal et al. (2020) ; Holzapfel et al. (2025) . The state mapping is typically mediated by a motional degree of freedom common to the ions which are strongly coupled by the Coulomb interaction. In general, a QLS experimental sequence consists of three steps: first, cooling of a common (target) motional mode, second, manipulation of the target mode population depending on the internal state of the spectroscopy ion and third, motional-state readout by spectroscopy on the logic ion. The QLS implementations demonstrated so far used different approaches to project the state of the spectroscopy ion onto the motional state. Several experiments involved adding a phonon to a target mode initially cooled to its ground state by driving a transition on a motional sideband of a spectroscopic transition in the spectroscopy ion Hume et al. (2007) ; Holzapfel et al. (2025) ; Chou et al. (2017) ; Micke et al. (2020) . In such a scheme, the addition of a phonon to the target mode indicated a successful state detection. In another approach, the target mode was prepared in the first excited motional Fock state, |1\rangle , and depending on the internal state of the spectroscopy ion, a single phonon was exchanged with another mode Wolf et al. (2016) . This mode transfer was mediated by a state-dependent optical dipole force (ODF) resonantly driving the mode exchange. Both of these approaches involved single-phonon excitations. A third method relies on a modulated state-dependent ODF tuned to resonance with the target motional mode, thus causing motional excitation Hume et al. (2011) ; Sinhal et al. (2020) . Depending on the duration of the ODF pulse and the state of the spectroscopy ion, the target mode can thus be excited to highly excited motional states. Various alternative implementations of QLS were proposed Mur-Petit et al. (2012) ; Loh et al. (2014) ; Hudson and Campbell (2018) ; Campbell and Hudson (2020) . Here, we further explore the third QLS method mentioned above, which employs a state-dependent ODF to determine the internal state of the spectroscopy ion Hume et al. (2011) ; Meir et al. (2019) ; Sinhal et al. (2020) ; Najafian et al. (2020) . The ODF is modulated at a frequency resonant with a normal mode of the two-ion system (referred to as target mode) and its amplitude depends on the internal state of the spectroscopy ion. The resulting resonant motional excitation of the system’s motional mode is probed by the logic ion using sideband spectroscopy Meekhof et al. (1996) ; Leibfried et al. (2003) and thus provides information about the state of the spectroscopy ion. Cooling the target mode close to its quantum-mechanical ground state is a prerequisite for most implementations of QLS mediated with motional states. However, population in the remaining normal modes which do not directly participate in the measurement protocol (spectator modes) could have detrimental effects on the spectroscopy due to Kerr-like Roos et al. (2008) , mode-cross-talk Wineland et al. (1998) ; Marquet et al. (2003) or Debye-Waller (DW) Wineland et al. (1998) effects. Consequently, it is common to set the frequencies of all the modes to be well-separated (i.e. avoid any resonances), and to cool all modes to sub-Doppler temperatures Chou et al. (2017) ; Marshall et al. (2025) . Here, we study in detail the consequences for QLS of the DW effect that modifies light-ion interaction strength due to motion of the ion. This effect was shown to be of relevance for applications in precision spectroscopy, quantum simulations, and quantum computing with multiple ions Wineland et al. (1998) ; Schmidt et al. (2005) ; Bermudez et al. (2017) ; Chen et al. (2017) ; Bruzewicz et al. (2019) ; Affolter et al. (2020) . DW effects are present in two stages of the present QLS method. First, population in the spectator modes may alter the interaction of the molecule with the ODF pulse. Second, it also affects the readout of the motional excitation with sideband spectroscopy, leading to a reduced signal-to-noise ratio and, thus, decreased state-detection fidelities. While the second effect was shown to be small in previous studies Sinhal et al. (2020) , the first can have significant ramifications for the state-detection fidelity, as shown here. We experimentally observe differences in response to the ODF pulse when the two-ion Coulomb crystal was prepared in specified spectator mode states. We rationalized these differences with the aid of analytical models and numerical simulations. We show that the spectator modes play an important role during the motional excitation via the DW effect. By cooling the axial spectator mode close to its ground state, we achieve an improved computed statistical state-detection fidelity, exceeding 99.99% for as few as nine experimental repetitions. Compared to 99.5% after 22 cycles reported previously when only the target mode was cooled Sinhal et al. (2020) , the execution time of the protocol was halved, while simultaneously achieving a more precise state determination. Furthermore, we show that the improved sensitivity of the detection method can also assist in the identification of higher-lying rotational states of the molecule. 2 Methods Figure 1: Experimental scheme. a. Schematic of the ion trap with relevant laser beams indicated. b. Partial Zeeman-resolved energy level scheme of 40 Ca + with spectroscopic transitions used for EIT cooling (blue) and sideband cooling (red) indicated, together with two repumping lasers (pink). c. Typical pulsed sideband cooling sequence. Each box represents repeated pulses on a red sideband of a (4s)^{2}S_{1/2}(m_{j}=-1/2)\rightarrow(3d)^{2}D_{5/2}(m_{j}=-5/2) transition in Ca + or pulses on a (4s)^{2}S_{1/2}(m_{j}=+1/2)\rightarrow(3d)^{2}D_{5/2}(m_{j}=-3/2) transition