Two-dimensional Synchrotron Beam Shape Characterization using Interferometric Closure Amplitudes Journal: osajournal Publication type: Research Article

Nithyanandan Thyagarajan, \authormark 1,2,* Bojan Nikolic, \authormark 2 Christopher L. Carilli, \authormark 3 Laura Torino, \authormark 4 and Ubaldo Iriso, \authormark 4 · 2025

Read Two-dimensional Synchrotron Beam Shape Characterization using Interferometric Closure Amplitudes Journal: osajournal Publication type: Research Article by Nithyanandan Thyagarajan, \authormark 1,2,* Bojan Nikolic, \authormark 2 Christopher L. Carilli, \authormark 3 Laura Torino, \authormark 4 and Ubaldo Iriso, \authormark 4 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-02036.txt.

Introduction

Nithyanandan Thyagarajan and co-authors published this study in 2025. It borrows a trick from radio astronomy to profile a light beam in two dimensions. Synchrotron facilities need to know their beam's exact shape. Older optical methods need several interferograms or precise knowledge of uneven lighting across the aperture. The borrowed trick uses closure amplitudes, ratios that cancel out lighting errors by design.

With a single interferogram through a masked aperture, the method recovers the beam profile at fine angular detail. Even time-varying lighting does not disturb it, allowing longer averaging and lighter data loads. The team tested it on real data from the ALBA synchrotron in Spain. Results matched existing methods. It is the first real-world use of closure amplitudes for direct beam profiling in optics.

Catalog record

CREATORNithyanandan Thyagarajan, \authormark 1,2,* Bojan Nikolic, \authormark 2 Christopher L. Carilli, \authormark 3 Laura Torino, \authormark 4 and Ubaldo Iriso, \authormark 4
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE30 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-02036

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Two-dimensional Synchrotron Beam Shape Characterization using Interferometric Closure Amplitudes Journal: osajournal Publication type: Research Article Nithyanandan Thyagarajan, \authormark 1,2,* Bojan Nikolic, \authormark 2 Christopher L. Carilli, \authormark 3 Laura Torino, \authormark 4 and Ubaldo Iriso, \authormark 4 Abstract Synchrotron radiation interferometry (SRI) is widely used in particle accelerators to monitor the transverse beam profile, and thus the critical beam emittance parameter. We introduce a novel technique to SRI using closure amplitudes, inspired by radio interferometry, to determine the two-dimensional profile of the synchrotron beam. Previous techniques have required multiple interferograms or accurate estimates of the non-uniform aperture illuminations. In contrast, our method using closure amplitudes avoids the need to estimate the aperture illuminations while determining the two-dimensional beam shape from a single interferogram. The invariance of closure amplitudes to even time-varying aperture illuminations makes it suitable to longer averaging intervals, with potential to reducing data rates and computational overheads. Using data from the ALBA synchrotron light source and having validated the results against existing methods, this paper represents one of the first real-world applications of interferometric closure amplitudes to directly determine the light source shape. Keywords: Aperture synthesis, Fourier optics and optical processing, Fourier transforms, Image reconstruction, Imaging techniques, Interferometry 1 Introduction Particle accelerators play a vital role in advancing science and technology across diverse fields such as nuclear and high-energy physics, energy production, medical applications, atomic and molecular physics, earth sciences, materials science, chemistry, molecular biology, and several industrial applications [ 1 ] . A critical property of particle beams in particle accelerators is their emittance – the area they occupy in position-momentum phase space. Maintaining low emittance is a key figure of merit in particle accelerators. Low emittances enhance luminosity in colliders and maximize the flux brilliance in synchrotron light sources. Because the emittance is not a directly measurable parameter, it is often inferred by measuring the transverse beam shape coupled with the knowledge of the machine’s Twiss parameters [ 1 ] . Due to its non-invasive nature, imaging using the synchrotron radiation produced by the particle beam is often used to measure the transverse shape of the beam [ 2 ] . For low emittance (and thus, small beam size) accelerators, direct imaging techniques use the X-ray part of the synchrotron radiation to avoid the diffraction limit (for example, the X-ray pinhole method [ 3 ] ). At longer wavelengths, i.e. visible range, Synchrotron Radiation Interferometry (SRI) is a widely used technique, a fundamental advancement of which is the subject of this paper. Traditionally, SRI involved the use of a two-aperture mask at visible wavelengths, where photons passing through the holes interfere on the CCD. The apertures can be holes or slits. The resulting interferogram is influenced by the size and illumination of the apertures, and their separation. The size of a one-dimensional beam profile can be determined by measuring how the visibility of the interferogram changes with different aperture separations. If the beam has a Gaussian shape, this measurement can be done with a single acquisition [ 4 , 5 ] . Recent advancements have enhanced SRI techniques, addressing the limitation of measuring only one-dimensional profiles. One notable development involves the use of a rotating two-hole mask at ALBA, allowing for the estimation of the two-dimensional Gaussian beam profile [ 6 ] . Another advancement employs a four-hole aperture in a square layout, capturing spatial coherence information along both vertical and horizontal directions to enable two-dimensional profiling, as demonstrated on the Spring-8 storage ring [ 7 ] . In multi-hole apertures, non-uniform illumination and phase disturbances across the holes can degrade coherence and affect the interferogram. If the hole-to-hole variations in phase and illuminations are not properly accounted for, the loss of coherence will irrecoverably bias the estimated beam profile to larger shapes. To mitigate this, [ 8 ] introduced a refined SRI method by adapting radio interferometry techniques [ 9 , 10 ] , such as amplitude self-calibration and simultaneous source modeling. This approach leverages a non-redundant hole layout in the aperture plane, ensuring that each spatial frequency corresponds to a unique hole-pair. By measuring spatial correlations (visibilities) in the aperture plane, the method fits the data for both hole illuminations and beam shape parameters through amplitude self-calibration. The advantage of this technique is in its ability to determine the two-dimensional beam profile and non-uniform aperture illumination simultaneously, provided that a sufficiently large array of non-redundantly spaced holes spans the aperture. This amplitude self-calibration approach represents a significant adaptation of radio-frequency interferometric techniques– where light is treated as a wave and thus coherent measurement and amplification of the electric fields is possible– to SRI, where the particle nature of light being the dominant framework allows only the measurement of photon’s intensities and not their phases. The above cross-disciplinary approach motivates further integration of powerful radio interferometry concepts into SRI. Here, we take an alternate approach to addressing coherence loss caused by non-uniform hole illumination through the use of closure amplitudes [ 11 , 9 , 10 ] . Closure amplitudes belong to a class of interferometric data combinations, called closure invariants [ 12 , 13 ] , that inherently eliminate the need to calibrate hole-based amplitudes that are not intrinsic to the source. Closure invariants have been instrumental in situations where calibration of the aperture behavior and propagation effects are challenging, such as in Very Long Baseline Interferometry [ 9 , 14 ] . For example, closure quantities have played a key role in major astronomical discoveries, including the identification of morphologies and superluminal expansions of jets of quasars [ 15 , 16 , 11 , 17 , 18 ] , and the event horizon-scale imaging of the supermassive black holes in the M87 and Milky Way galaxies [ 19 , 20 ] . In this paper, we introduce and validate a novel closure amplitude-based method for SRI that analytically reconstructs the two-dimensional transverse beam profile and avoids the need to calibrate the hole illumination. This method has the potential to extend beyond SRI to interferometric applications at optical and other wavelengths. The paper is organized as follows. The synchrotron beam parametrization is described in section 2 . Section 3 presents the experimental setup and data used in this study. In section 4 , we describe the framework and the reference method before presenting the novel analysis method developed in this study. The results and conclusions are presented in sections 5 and 6 , respectively. 2 Synchrotron Beam Model The transverse profile of a synchrotron beam is well-modeled as a two-dimensional Gaussian [ 21 ] , which we parametrize as \displaystyle I(\bm{\ell}) \displaystyle=I_{0}\,\exp\left(-\frac{1}{2}\bm{\ell}^{\intercal}\bm{\Sigma}_{\bm{\ell}}^{-1}\bm{\ell}\right)\,, (1) where, \bm{\ell}\coloneqq\begin{bmatrix}\ell&m\end{bmatrix}^{\intercal} denotes the coordinates describing the image plane, and \bm{\Sigma}_{\bm{\ell}} is the covariance matrix of a rotated two-dimensional Gaussian in this plane. The semi-principal axes of the ellipse corresponding to the \bm{\ell}^{\intercal}\bm{\Sigma}_{\bm{\ell}}^{-1}\bm{\ell}=1 contour are denoted by \sigma_{\textrm{maj}} and \sigma_{\textrm{min}} , respectively. The tilt angle of the major axis anti-clockwise from the \ell -axis is denoted by \theta . The spatial coherence, \gamma(\mathbf{u}) , in the aperture plane denoted by coordinates, \mathbf{u}\coloneqq\begin{bmatrix}u&v\end{bmatrix}^{\intercal} , related to the intensity distribution in the image plane by the van Cittert-Zernike relation [ 22 ] can be approximated by a Fourier transform [ 9 , 10

Read the complete text