Read Non-collocated vibration absorption using delayed resonator for spectral and spacial tuning – analysis and experimental validation by Matěj Kuře, Adam Peichl, Jaroslav Bušek, Nejat Olgac, Tomáš Vyhlídal (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2504-01812.txt.

Introduction

Matěj Kuře and co-authors study a way to soak up shaking in a structure when the absorber cannot sit at the spot that shakes. Their device is a delayed resonator, a part whose response is timed to cancel the shake at a chosen pitch and place.

The team give a math path to check the idea for chains of linked masses of any size. They then build a rig of three linked carts and test it. At one chosen pitch, the device hushed each cart in turn, the one at its side and the two far ones. Test results matched the model well, which backs both kinds of tuning.

Catalog record

CREATORMatěj Kuře, Adam Peichl, Jaroslav Bušek, Nejat Olgac, Tomáš Vyhlídal
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE34 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2504-01812

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Non-collocated vibration absorption using delayed resonator for spectral and spacial tuning – analysis and experimental validation Matěj Kuře, Adam Peichl, Jaroslav Bušek, Nejat Olgac, Tomáš Vyhlídal Abstract Non-collocated vibration absorption (NCVA) concept using delayed resonator for in-situ tuning is analyzed and experimentally validated. There are two critical contributions of this work. One is on the scalable analytical pathway for verifying the concept of resonant substructure as the basis of the ideal vibration absorption. The second is to experimentally validate the spatial and spectral tunability of NCVA structures for the first time. For both novelties arbitrarily large dimensions of interconnected mass-spring-damper chains are considered. Following the state of the art on NCVA, control synthesis is performed over the resonant substructure comprising the delayed resonator and a part of the primary structure involved in the vibration absorption. The experimental validation of the proposed NCVA concept is performed on a mechatronic setup with three interconnected cart-bodies. Based on the spectral analysis, an excitation frequency is selected for which a stable vibration suppression can be achieved sequentially for all the three bodies, one collocated and two non-collocated. The experimental results closely match the simulations for complete vibration suppression at the targeted bodies, and thus validating the crucial spatial tunability characteristic as well as the traditional spectral tuning. Journal: Automatica 1 Introduction Vibration absorbers have proven to be effective in a variety of engineering applications [ 1 ] . In the traditional collocated vibration absorption task, the absorber is deployed at the place of the mechanical structure, where vibration is to be suppressed. The spectral tuning of the collocated absorber is a relatively straightforward task and has been widely addressed in literature, see e.g., [ 2 ] , [ 3 ] with passive, [ 4 ] with semi-active, and [ 5 ] with active tuning methods. In many applications, however, due to operational reasons, the absorber needs to be deployed in a non-collocated manner, i.e., at a different location from the vibration suppression target. The design and the tuning of such an absorber is a considerably more difficult task because a part of the primary structure between the absorber and the suppression target has to be engaged in the action. In this paper, we focus on the analysis and the experimental validation of non-collocated vibration absorption (NCVA) using the delayed resonator (DR) tuning procedure, which was presented recently by Olgac and Jenkins, [ 6 ] , [ 7 ] , see also [ 8 ] . The DR tuning scheme was proposed in the 90s by Olgac and his co-workers primarily for collocated vibration absorption . Since then, it has become a traditional tool for (collocated) vibration absorption and a benchmark case revealing potential benefits of involving time delays in the feedback control law. DR is an active vibration absorber which is created using a decentralized time-delayed feedback scheme executed on the absorber’s position [ 9 ] , velocity [ 10 ] , or acceleration [ 11 ] . The time-delayed feedback is applied to turn the absorber substructure into an ideal resonator which completely suppresses the vibration. Please note that, traditionally, the DR is always tuned to be marginally stable (i.e., with a characteristic root pair placed at \pm\jmath\omega , \omega being the excitation frequency) [ 12 ] . This concept is extended to NCVA deployment, this time however, entailing the absorber as well as a part of the primary structure. This newly composed segment was named as the resonant substructure [ 7 ] . In this paper, we present another analytical pathway reinforcing this critical aspect. A practical benefit of the DR is that in the standard collocated setting, neither measurements at the primary structure, nor its physical parameters are involved in the DR design. From the wide literature on the DR, let us mention a torsional absorber [ 13 ] , an auto-tuning algorithm to enhance the robustness against uncertainties [ 14 ] and multiple DR application [ 15 ] . Recent DR design and analysis topics include stability analysis [ 16 ] , combination of position and velocity feedback [ 17 ] , DR with distributed delays [ 18 ] , [ 19 ] , targeting two frequencies [ 20 ] , enhancing the robustness in vibration absorption [ 21 ] , [ 22 ] , fractional order DR [ 23 ] , and the DR concept extension to two [ 24 ] , [ 25 ] , and three [ 26 ] , [ 27 ] dimensional vibration absorption. Let us also point to delay-free resonator alternatives to the DR. In [ 28 ] a PI acceleration feedback of the absorber was proposed, supplemented by a low and high pass filters. In [ 29 ] , the concept of linear active resonator (LAR) was introduced by Filipovic and Schröder. Conceptually, it mirrors the DR structure with a tuneable gain, which, however, is in a series with rational transfer function instead of the sole delayed term used in DR. After outlining the development and recent topics on collocated DR concept, let us turn the attention to the non-collocated case. In [ 6 ] , [ 7 ] , Olgac and Jenkins demonstrated that the DR is applicable for non-collocated vibration absorption of a system composed of a serial interconnection of flexibly linked masses. They showed that compared to the collocated DR design, the part of the primary structure between the position to be silenced and the position where the DR is deployed needs to be included in tuning the control logic. The DR together with this part of the primary forms the resonant substructure , which needs to be tuned as a whole. It was also discussed in [ 6 ] , [ 7 ] that the resonant substructure can only be identified under some restrictions on the physical deployment. Note that the findings of Olgac and Jenkins confirm the earlier results by Filipovic and Schröder presented in [ 30 ] , where an analogous problem of remote (non-collocated) vibration suppression at a system composed of series of flexibly linked masses is solved by the LAR. Subsequent to works by Olgac and Jenkins, in [ 31 ] , a spectral design of non-collocated vibration suppression performed primarily by a DR is presented. The method is based on a purely imaginary pair of active zero assignment to the transfer function between the excitation force and the target position to be silenced. As such, it is also applicable to setups, where the resonant substructure cannot be defined. For such cases, in order to increase the stability margin, an additional stabilizing controller is included and tuned. In the follow-up work [ 32 ] , an output feedback controller is used to assign the active zero couple and to stabilize the system with feedback delay. The synthesis is performed by a spectral optimization. The results of both [ 31 ] and [ 32 ] are experimentally validated on a mechatronic setup with cart-bodies targeting vibration suppression at a single body. In [ 33 ] the simultaneous imaginary zero assignment and stabilization at the non-collocated vibration suppression is achieved by a DR with multiple static delay feedback. In this paper, building up on the results by

Read the complete text