Anthropomorphic tissue-mimicking phantoms for oximetry validation in multispectral optical imaging
Kris K. Dreher, Janek Gröhl, Friso Grace, Leonardo Ayala, Jan-Hinrich Nölke, Christoph J. Bender, Melissa J. Watt, Catherine-Louise White, Ran Tao, Wibke Johnen, Minu D. Tizabi, Alexander Seitel, Lena Maier-Hein, Sarah E. Bohndiek · 2025
Read Anthropomorphic tissue-mimicking phantoms for oximetry validation in multispectral optical imaging by Kris K. Dreher, Janek Gröhl, Friso Grace, Leonardo Ayala, Jan-Hinrich Nölke, Christoph J. Bender, Melissa J. Watt, Catherine-Louise White, Ran Tao, Wibke Johnen, Minu D. Tizabi, Alexander Seitel, Lena Maier-Hein, Sarah E. Bohndiek (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-23161.txt.
Introduction
Kris Dreher and co-authors build fake tissue for testing oxygen imaging in a 2025 paper. Light based scans can read blood oxygen from how hemoglobin absorbs color, but clinics lack trusted test objects to check the readings. Their phantoms mimic human tissue shape and optics. A stable copolymer in oil base forms the body of each phantom.
Known oxygen levels inside the phantoms give the ground truth scanners must match. Human like shapes matter, since light scatter depends on form as much as on chemistry. Shared standards let hospitals and makers compare devices on equal footing. The work fills a dull but vital gap between a clever scan method and a clinic ready tool.
Catalog record
| CREATOR | Kris K. Dreher, Janek Gröhl, Friso Grace, Leonardo Ayala, Jan-Hinrich Nölke, Christoph J. Bender, Melissa J. Watt, Catherine-Louise White, Ran Tao, Wibke Johnen, Minu D. Tizabi, Alexander Seitel, Lena Maier-Hein, Sarah E. Bohndiek |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-23161
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Anthropomorphic tissue-mimicking phantoms for oximetry validation in multispectral optical imaging Kris K. Dreher, Janek Gröhl, Friso Grace, Leonardo Ayala, Jan-Hinrich Nölke, Christoph J. Bender, Melissa J. Watt, Catherine-Louise White, Ran Tao, Wibke Johnen, Minu D. Tizabi, Alexander Seitel, Lena Maier-Hein, Sarah E. Bohndiek Abstract Significance: Optical imaging of blood oxygenation (sO 2 ) can be achieved based on the differential absorption spectra of oxy- and deoxy-haemoglobin. A key challenge in realising clinical validation of the sO 2 biomarkers is the absence of reliable sO 2 reference standards, including test objects. Aim: To enable quantitative testing of multispectral imaging methods for assessment of sO 2 by introducing anthropomorphic phantoms with appropriate tissue-mimicking optical properties. Approach: We used the stable copolymer-in-oil base material to create physical anthropomorphic structures and optimised dyes to mimic the optical absorption of blood across a wide spectral range. Using 3D-printed phantom moulds generated from a magnetic resonance image of a human forearm, we moulded the material into an anthropomorphic shape. Using both reflectance hyperspectral imaging (HSI) and photoacoustic tomography (PAT), we acquired images of the forearm phantoms and evaluated the performance of linear spectral unmixing (LSU). Results: Based on 10 fabricated forearm phantoms with vessel-like structures featuring five distinct sO 2 levels (between 0 and 100%), we showed that the measured absorption spectra of the material correlated well with HSI and PAT data with a Pearson correlation coefficient consistently above 0.8. Further, the application of LSU enabled a quantification of the mean absolute error in sO 2 assessment with HSI and PAT. Conclusion: Our anthropomorphic tissue-mimicking phantoms hold potential to provide a robust tool for developing, standardising, and validating optical imaging of sO 2 . keywords anthropomorphic phantoms, optical imaging, oximetry, photoacoustic imaging, hyperspectral imaging * Corresponding authors: KKD, LMH {k.dreher, l.maier-hein}@dkfz-heidelberg.de, SEB \linkable [email protected] \dagger Shared last authorship 1 Introduction Oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (Hb) are critical endogenous contrast agents that enable noninvasive measurement of blood oxygen saturation (sO 2 ) , also referred to as oximetry, due to their distinct optical absorption spectra. Oximetry methods are invaluable for a range of clinical applications throughout the patient care pathway, from diagnosis to treatment planning, and monitoring of treatment response [ 1 , 2 , 3 , 4 , 5 ] . Pulse oximetry is the most widely available of these tools, which employs red and infrared light to noninvasively estimate sO 2 for bulk tissue at a single measurement site, such as a fingertip [ 1 ] . To obtain spatially resolved information, for example in image-guided surgery, imaging modalities like hyperspectral imaging (HSI) and photoacoustic tomography (PAT) are used. HSI and PAT typically involve making wavelength-resolved measurements across the visible and near-infrared spectral range [ 1 ] . HSI uses light diffusely reflected from the tissue to map HbO 2 and Hb signals near the tissue surface [ 6 , 7 ] , whereas PAT combines pulsed laser illumination and ultrasonic detection to probe deeper tissue layers [ 8 , 9 ] . In both techniques, deriving sO 2 from spectral data commonly relies on linear spectral unmixing (LSU) [ 10 , 11 ] , assuming that the optical absorption responsible for the image contrast is a linear combination of the absorption spectra of all contrast agents present at any given point weighted by their concentration. Accurately quantifying sO 2 in HSI and PAT is challenging, since a range of assumptions are made in both the datacube (x,y, \lambda ) reconstruction and spectral analysis pipeline that can lead to corruption of the measured tissue biomarkers. For example, in HSI , signals can be distorted due to additional optical interactions, such as fluorescence, while in PAT , depth-dependent signal attenuation arises, known as spectral colouring. In both modalities, patient motion and skin tone bias can introduce further complexity [ 12 , 10 ] . Consequently, developing robust oximetry calibration methods for HSI and PAT remains an active area of research [ 13 , 14 , 15 , 16 ] . For the development and rigorous validation of any scientific method, including oximetry, a reliable performance measure or reference is essential. In oximetry, however, the principal challenge is that an in vivo ground truth for sO 2 is not available noninvasively with current technology. Therefore, many studies only rely on qualitative visualisations or measurement of relative changes in the same individual or specimen over time, rather than calibrating for absolute sO 2 [ 17 , 18 , 19 ] . Validation approaches can take several forms. Validation can be developed by comparison to simulated data, however, these often fail to generalise when applied in vivo tissue [ 20 ] . Adding a level of complexity, experimental data obtained from bulk test objects (’phantoms’) made with a mixture of blood, haemoglobin or other biological solutions [ 21 , 22 ] can closely mimic tissue spectra and facilitate validation, but typically: do not allow well-controlled adjustment of sO 2 , lack internal structure, tend to be unstable over time, and are prone to bacterial contamination [ 23 , 24 ] . Addressing some of these limitations, blood flow phantoms allow for chemical manipulation of sO 2 as blood flows through a circuit while being imaged [ 25 , 26 ] . Nevertheless, blood flow circuits rely on ancillary reference measurements (e.g., partial pressure probes or offline oximeters) to provide a gold standard reference and are typically simple in their structure e.g. a tube flowing through a slab of base material. Anthropomorphic phantoms with stable, tissue-mimicking optical properties over a broad wavelength range remain rare [ 27 ] . Obtaining oximetry estimations from anthropomorphic phantoms typically requires embedding a flow circuit within a complex material composition, which is prohibitively challenging. To overcome this limitation and tackle the challenge of oximetry validation in HSI and PAT , we introduce an anthropomorphic phantom design that mimics the morphology of a human forearm and includes absorbing dyes that replicate the absorption coefficient ( \mu_{a} ) characteristics of HbO 2 and Hb between 700 nm and 850 nm. We first select and optimise dye proxies for Hb and HbO 2 . We then created 3D-printable moulds derived from human forearm imaging to achieve morphologically relevant geometry, which are available open-source. Using a copolymer-in-oil base material, we created structurally stable anthropomorphic forearm phantoms with optical characteristics confirmed via simulation studies and signal correlation analyses. Finally, we demonstrated the value of the created phantoms for oximetry validation in HSI and PAT . These phantoms provide a versatile, morphologically realistic test platform for oximetry validation in the near-infrared. 2 Materials and methods Combining dye proxies with anthropomorphic phantom designs in this study enables a new approach to oximetry validation (Fig. 1 ). Figure 1 : Workflow and key contributions of this study. (Top) First, 26 dyes were investigated to mimic the absorption spectra of oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (Hb) in the wavelength ( \lambda ) range of 700 nm to 850 nm. After a selection and optimisation process, two proxy dyes that could be mixed to 5 levels of oxygen saturation (sO 2 ) (0%, 30%, 50%, 70%, 100%) were found. Second, for realistic tissue morphology, a 3D-printable mould was created based on