Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections
Hunter C. Meyer, Conner B. Dooley, Victoria L. Fontenot, Kyungmin Ham, Leslie G. Butler, Alexandra Noël, Joyoni Dey · 2025
Read Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections by Hunter C. Meyer, Conner B. Dooley, Victoria L. Fontenot, Kyungmin Ham, Leslie G. Butler, Alexandra Noël, Joyoni Dey (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-23148.txt.
Introduction
Hunter Meyer and six co-authors improve an X-ray imaging method in this two thousand twenty-five paper. Grating interferometry uses a fine grating to split X-rays into a fringe pattern. A sample bends that pattern, yielding three images at once: absorption, phase shift, and small-angle scattering. Such images could serve lung and breast screening and factory testing. The method assumes a perfectly even pattern, which real setups break.
Uneven grating steps and extra harmonics in the fringes leave wavy artifacts in the images. The authors correct for both flaws at once. They model several harmonics of the fringe pattern and fix the step errors. Cleaner images bring this young modality closer to clinical use. Imaging physicists are the audience.
Catalog record
| CREATOR | Hunter C. Meyer, Conner B. Dooley, Victoria L. Fontenot, Kyungmin Ham, Leslie G. Butler, Alexandra Noël, Joyoni Dey |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 28 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-23148
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections Hunter C. Meyer, Conner B. Dooley, Victoria L. Fontenot, Kyungmin Ham, Leslie G. Butler, Alexandra Noël, Joyoni Dey Abstract X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina. 1. Introduction X-ray interferometry is a developing imaging modality with a wide variety of potential clinical and industrial applications, including lung imaging [ 1 , 2 , 3 , 4 ] , breast imaging [ 5 , 6 , 7 , 8 ] , pore size analysis [ 9 , 10 ] , and additive manufacturing quality assurance [ 11 , 12 ] . A grating interferometer works by producing a periodic fringe pattern by placing a diffraction grating between an X-ray source and detector. Three unique images are produced by measuring perturbations in the fringe pattern [ 13 , 14 ] . X-ray absorption decreases the average value of the interference fringes, producing the transmission image, which is the same as a traditional X-ray. Refraction produces a lateral shift in the pattern, producing the differential-phase image. Small angle X-ray scatter reduces the fringe visibility, producing the dark-field image. The amount of dark-field signal depends on the system’s autocorrelation length (ACL) and microstructures of the sample being imaged [ 15 , 16 , 17 ] . Grating interferometers commonly use a technique known as phase stepping to acquire images. The grating is translated laterally and imaged multiple times to produce a phase stepping curve at each pixel. Two phase stepping curves are acquired, one with no sample that serves as a reference curve and one with a sample in place, and the fringes are analyzed and compared on a per-pixel basis to simultaneously produce the three images. The phase stepping curves are typically assumed to be sinusoidal, and the average value, visibility, and phase are extracted and compared to produce the three images. Phase stepping requires the use of high precision electronic motors, since the phase steps are on the micron level and at least five phase steps are usually acquired. A key problem with a grating interferometer is small inaccuracies in grating position and the fact that the fringes are not perfectly sinusoidal, leading to image artifacts that are unique to grating interferometry. The artifacts appear as remnant fringes in the transmission, differential-phase, and dark-field images due to oscillations in the sinusoidal fit parameters since the fringes were non-sinusoidal to begin with and the true phase steps are not evenly spaced. When the sample phase stepping curve is acquired and compared with the reference phase stepping curves, the oscillation in the fit parameters does not perfectly line up, leading to remnant fringes in the three images. Additionally, the differential-phase image will have phase wraparound, leading to bright stripes in the images. We propose the use of corrected phase step positions and multiple harmonics in the analysis of the phase stepping curves to decrease or completely remove the fit parameter oscillation which leads to remnant fringes in the transmission, differential-phase, and dark-field images. We also propose the inclusion of the reference phase into the sample’s phase stepping curve so that the relative phase is fit directly, preventing phase wraparound. With the introduction of multiple harmonics and the phase wraparound correction, we redefine how our images are calculated in a simple and intuitive manner. Previous work on Moiré artifacts resulting from phase stepping errors and dose fluctuations has been reported [ 18 , 19 , 20 , 21 ] . They require iterative approaches which could have convergence or bias issues, particularly in the differential-phase image if the average difference in the true and nominal phase step positions between the reference and sample phase stepping curves is not negligible. The methods presented in this paper for correcting phase stepping errors are do not require iteration. To the best of our knowledge, we are the first to analyze multiple harmonics and their influence on images produced with grating interferometers. 2. Methods The Modulated Phase Grating Interferometer (MPGI) is a recently developed X-ray system that is capable of interferometry without an analyzer grating [ 22 , 23 , 24 , 25 , 10 ] , shown in Figure 1 . The Modulated Phase Grating (MPG) is a diffraction grating that produces a periodic intensity pattern using either a microfocus source or standard X-ray source with a source grating, G0. The MPG has grating bars separated by a pitch, p , and the bar heights follow an envelope function with period, W . In the example shown, the envelope function is a RectMPG with phase-heights (H_{1},H_{2}) . The fringes produced by the MPG follow the period of the envelope function, W , and the smaller pitch, p , determines the coherence requirements to be in accordance with other X-ray interferometers. Because W is fairly large, the fringes produced by the MPG are directly resolvable for standard high resolution X-ray detectors, meaning no analyzer grating is required. Figure 1 : Schematic of the Modulated Phase Grating Interferometer, shown with a RectMPG. The G0 grating is optional and not used in this study. Transmission, differential-phase, and dark-field images are calculated by acquiring two phase-stepping curves: a reference curve and a sample curve. A phase-stepping curve is a series of images generated by imaging the grating at several phase stepping positions, where the grating is laterally shifted over at least one period. The phase stepping curves are analyzed on a pixel-by-pixel basis by fitting the measured intensity to a sinusoidal function shown in Equation 1 , where x_{g} is the phase stepping position, W is the period of the grating, and the fit parameters are a_{0} , a_{1} , and \phi_{1} , representing the average value, amplitude, and phase of the fringe pattern, respectively. The subscript 1 represents that only one harmonic was used, and the superscripts represent distinct equations for the reference, r, and sample, s. The fringe visibility is the ratio of the amplitude and average value, V=\frac{a_{1}}{a_{0}} . The phase stepping positions