Leveraging partial coherence in interferometric microscopy to enhance nanoparticle detection sensitivity and throughput
Chiara Lombardo, Andrea Sottini, Sarina Seiter, Gerard Colas des Francs, Jaime Ortega Arroyo, Romain Quidant · 2025
Read Leveraging partial coherence in interferometric microscopy to enhance nanoparticle detection sensitivity and throughput by Chiara Lombardo, Andrea Sottini, Sarina Seiter, Gerard Colas des Francs, Jaime Ortega Arroyo, Romain Quidant (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-22565.txt.
Introduction
Chiara Lombardo, Andrea Sottini, and four colleagues tune the coherence of light in an interferometric microscope to spot nanoparticles more reliably, in a paper published in two thousand twenty-five. Such microscopes watch single particles without labels, in real time, which makes them prized for chemistry and materials work.
Fully coherent light brings speckle and stray interference that muddy the image. Fully incoherent light is dim. The team maps out the middle ground: how partial coherence changes signal contrast and background noise together. The balance point lifts the signal-to-noise ratio for single particles whatever their size or composition, and whatever source is used. They also show lasers can be modified into partially coherent sources that perform at that level. The payoff is sensitivity and throughput at once, rather than trading one for the other.
Catalog record
| CREATOR | Chiara Lombardo, Andrea Sottini, Sarina Seiter, Gerard Colas des Francs, Jaime Ortega Arroyo, Romain Quidant |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 73 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-22565
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Leveraging partial coherence in interferometric microscopy to enhance nanoparticle detection sensitivity and throughput Chiara Lombardo, Andrea Sottini, Sarina Seiter, Gerard Colas des Francs, Jaime Ortega Arroyo, Romain Quidant Abstract Interferometric-based microscopies stand as powerful label-free approaches for monitoring and characterising chemical reactions and heterogeneous nanoparticle systems in real time with single particle sensitivity. Nevertheless, coherent artifacts, such as speckle and parasitic interferences, together with limited photon fluxes from spatially incoherent sources, pose an ongoing challenge in achieving both high sensitivity and throughput. In this study, we systematically characterise how partial coherence affects both the signal contrast and the background noise level; thus, it offers a route to improve the signal-to-noise ratio from single nanoparticles (NPs), irrespective of their size and composition; or the light source used. We first validate that lasers can be modified into partially coherent sources with performance matching that of spatially incoherent ones; while providing higher photon fluxes. Secondly, we demonstrate that tuning the degree of partial coherence not only enhances the detection sensitivity of both synthetic and biological NPs, but also affects how signal contrasts vary as a function of the focus position. Finally, we apply our findings to single-protein detection, confirming that these principles extend to differential imaging modalities, which deliver the highest sensitivity. Our results address a critical milestone in the detection of weakly scattering NPs in complex matrices, with wide-ranging applications in biotechnology, nanotechnology, chemical synthesis, and biosensing; ushering a new generation of microscopes that push both the sensitivity and throughput boundaries without requiring beam scanning. keywords digital holography, interferometric microscopy, nanophotonics, partial coherence, sensing, label-free imaging † † affiliation: Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland † † affiliation: Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland † † affiliation: Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland † † affiliation: Université Bourgogne Europe, CNRS, Laboratoire Interdisciplinaire Carnot de Bourgogne ICB UMR 6303, F-21000 Dijon, France † † affiliation: Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland † † email: [email protected] † † affiliation: Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland † † abbreviations: NA, iSCAT, BFP, FOV, LED, RGG, SNR, NP † † suppinfo: M \mciteErrorOnUnknownfalse 1 Introduction Recent advances in biotechnology, nanotechnology, material science, and chemical synthesis have enabled the engineering of new functional nanoparticle systems with applications ranging from gene delivery Pozzi and Caracciolo (2023) ; Tian et al. (2013) , targeted therapy Yetisgin et al. (2020) , biosensing Doria et al. (2012) to heterogeneous catalysis Sankar et al. (2020) . Additionally, molecular profiling biological nanoparticles found in the secretome like extracellular vesicles (EVs) hold promise as next-generation liquid biopsies Zhao et al. (2019) and drug delivery Elsharkasy et al. (2020) carriers. Consequently, there is a growing demand for high-throughput quantitative characterisation tools offering single particle sensitivity. By eliminating the need for sample handling and processing, label-free approaches are amongst the most suited for this task. Those based on interferometry stand out due to their inherent high sensitivity. The combination of shot-noise limited detection with high-photon flux light sources ensures that enough scattered photons from the smallest of nanoparticles reach the sensor and generate sufficient signal contrast, enabling single protein and nucleic acid detection, tracking and subsequent characterisation Dahmardeh et al. (2023) ; Ortega Arroyo et al. (2014) ; Piliarik and Sandoghdar (2014) as well as monitoring of complex reactions ranging from autocatalysis Ortega-Arroyo et al. (2016) , nanoparticle formation Guo et al. (2025) ; Guo et al. (2023) , covalent organic framework formation Gruber et al. (2024) and tracking of single particle ion dynamics Merryweather et al. (2021) . The requirement for high photon flux sources is typically satisfied using high-power CW lasers, which are both spatially and temporally coherent illumination sources. However, achieving high sensitivity at high throughput with these light sources, defined here in terms of size of the field of view (FOV) per unit time, remains a significant challenge. On the one hand, coherent artifacts such as speckles and parasitic interferences severely degrade the image quality for wide-field imaging Shin et al. (2017) , and on the other hand, reducing these artifacts by turning the imaging system into a partially coherent one comes at the expense of a smaller FOV. To best capture these differences, Fig. 1 illustrates the image formation principle in a reflection-based interferometric microscope for three different scenarios: i) a coherent imaging system with a spatially coherent light source, ii) a partially coherent imaging system with a spatially coherent light source, and iii) a partially coherent imaging system with a spatially incoherent light source. The first case (Fig. 1 b, left column) is represented by Koehler illumination, where larger FOVs result from focussing the light source tightly into the BFP of the objective, essentially lowering the spatial frequency bandwidth, which in turn increases the spatial coherence of the imaging system; thus leading to coherent artifacts and lower spatial resolution, as represented in the optical transfer function (OTF). The second case (Fig. 1 b, middle column), represents a partially coherent microscope resulting from increasing the size of the illuminating beam at the BFP, which can be experimentally achieved by weakly focussing a laser into the BFP, or confocally illuminating the sample. Under this scenario, the spatial frequency bandwidth increases, thus lowering the spatial coherence and increasing the resolution of the imaging system. However, this reduces the FOV as shown in the middle column of Fig. 1 b. Solutions to extend the FOV exist, either in the form of rapid beam scanning of a weakly focussed beam with acousto-optic beam deflectors Ortega-Arroyo and Kukura (2012) , raster scanning confocal detection Jacobsen et al. (2006) ; Küppers et al. (2023) , spinning disk confocal Hsiao et al. (2022) , or rotational integration of oblique scanning Liu et al. (2025) , yet come with drawbacks such as high peak intensities and limited scanning speeds that may ultimately restrict the throughput. The third case, showcases an alternative solution to this problem, which involves using a spatially incoherent illumination source Avci et al. (2015) ; Simmert et al. (2018) ; Yi et al. (2020) ; Stollmann et al. (2023) ; Wu et al. (2025) , such as multimode fiber-coupled light emitting diodes (LEDs), which not only delivers larger FOVs with minimal coherent artifacts, but also flat-top illumination profiles (Fig. 1 b right column). Although illuminations with large spatial coherence degrade the image quality of label-free interference-based microscopy, and partial coherent imaging systems should be preferred for imaging weakly scattering objects, the question how one should tailor the degree of partial coherence with spatially incoherent light sources to maximise the signal-to-noise ratio (SNR) to quantify single particle signals in the least amount of time is lacking. This study addresses this gap and provides a solution applicable to metallic, dielectric, and biological nanoparticles. To do so, we developed a platform that allows simultaneous tuning and measurement of the degree of partial coherence. We specifically characterised the dependence of the signal contrasts and the background noise contributions to find