Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise
Yuanke Feng, 1 Shumpei Fujimura, 1 Yiheng Lim, 1 Thitiya Seesan, 1 Rion Morishita, 1 Ibrahim Abd El-Sadek, 1,2 Pradipta Mukherjee, 1,3, Shuichi Makita, 1, and Yoshiaki Yasuno 1,* · 2025
Read Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise by Yuanke Feng, 1 Shumpei Fujimura, 1 Yiheng Lim, 1 Thitiya Seesan, 1 Rion Morishita, 1 Ibrahim Abd El-Sadek, 1,2 Pradipta Mukherjee, 1,3, Shuichi Makita, 1, and Yoshiaki Yasuno 1,* (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-20407.txt.
Introduction
Yuanke Feng and co-authors build a virtual test bench for a label-free imaging method that watches living tissue move. The method, dynamic optical coherence tomography, reads tiny motions inside cells from flickers in a light signal. What those flickers say about the motion underneath is still murky. Their framework simulates the whole chain, from moving scatterers inside model tissue to the image the instrument would form.
The simulator includes models of cell and tissue motion, two styles of signal generator, built-in measurement noise, and the standard analysis algorithms used on real data. Worked examples show how each piece behaves and where readings can mislead. The team released the framework as open source. They aim to give imaging researchers a ground truth they can test ideas against, since real tissue never reveals exactly what moved.
Catalog record
| CREATOR | Yuanke Feng, 1 Shumpei Fujimura, 1 Yiheng Lim, 1 Thitiya Seesan, 1 Rion Morishita, 1 Ibrahim Abd El-Sadek, 1,2 Pradipta Mukherjee, 1,3, Shuichi Makita, 1, and Yoshiaki Yasuno 1,* |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 54 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-20407
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise Yuanke Feng, 1 Shumpei Fujimura, 1 Yiheng Lim, 1 Thitiya Seesan, 1 Rion Morishita, 1 Ibrahim Abd El-Sadek, 1,2 Pradipta Mukherjee, 1,3, Shuichi Makita, 1, and Yoshiaki Yasuno 1,* Abstract Dynamic optical coherence tomography (DOCT) enables label-free functional imaging by capturing temporal OCT signal variations caused by intracellular and intratissue motions. However, the relationship between DOCT signals and the sample motion behind them remains unclear. This paper presents a comprehensive DOCT simulation framework that incorporates mathematical models of intracellular/intratissue motions, two OCT signal generator types that generate OCT signal time sequences from the moving scatterer models, and representative DOCT algorithms. The theory and algorithms of the framework are described in detail, and the utility of this framework is demonstrated through numerical studies. This framework is available as open source and will enhance the understanding and utility of DOCT. Journal: opticajournal Publication type: Research Article Publication type: Research Article 1 Introduction Dynamic optical coherence tomography (DOCT) is a label-free imaging method that is used to visualize tissue functions [ 1 ] . DOCT has been applied to the imaging of a wide spectrum of tissues, including ex vivo animal tissues [ 2 ] , in vitro spheroids [ 3 , 4 ] and organoids [ 5 ] , and in vivo human skin [ 6 ] . To obtain DOCT image contrast, multiple OCT frames are captured at the same location on a sample as a time sequence. Several DOCT signal types can be computed from such time sequences, including types that are sensitive to the magnitude of the signal fluctuations [ 3 , 7 ] , the decorrelation speed of the OCT signal [ 3 , 4 ] , and the time-frequency spectrum of the OCT signal [ 8 ] . The DOCT signal is a measure of the time property of the OCT signal, but it does not reflect the intracellular/intratissue motion directly. This can be understood by considering the following example. During the OCT signal formation process, moving scatterers within the tissue modulate the scattered light field. The light component that is scattered from each scatterer corresponds to a phasor contribution to the complex OCT signal, and a complex OCT signal at a single point in an OCT image is the summation of the multiple phasors. The OCT signal intensity is computed as an absolute-squared value of the complex OCT signal, i.e., as the product of the complex OCT and its complex conjugate. In this process, the phasor contributions mutually interact and form a speckle pattern [ 9 , 10 ] . Assume that a scatterer in the sample moves with uniform speed. Although the scatterer’s motion is a linear motion, the phase of the corresponding phasor oscillates with an oscillation frequency that is proportional to the axial component of the motion velocity. More complex cases can be exemplified by considering two scatterers that are moving at the same uniform speed but in different directions, i.e., at different axial speeds. First, the phasors that correspond to these scatterers have different phase-modulation frequencies, even though they are moving with the same speed (i.e., absolute velocity). Second, these phasors interact during the intensity-signal formation process and it results in additional frequency components in the intensity signal fluctuation that do not relate directly to either scatterer’s velocity. To date, the relationship between DOCT signals and the individual scatterer motions in the tissue has not been fully identified. As a result, the dynamic OCT contrast cannot really be interpretable. In this paper, we present a dynamic OCT simulation framework (i.e., a dynamic OCT simulator) that enables numerical investigation of the intracellular/intratissue-motion-to-DOCT-signal relationship. This simulation framework consists of mathematical models of the intracellular/intratissue scatterer motions that can be used to generate a numerical distribution of the scatterers, and a numerical OCT simulator that generates the OCT intensity pattern (i.e., the speckle pattern) from the scatterer distribution. By generating a time sequence of the numerical distributions of the dynamic scatterers using the scatterer motion models, the numerical OCT simulator can then generate the time sequence of the dynamic speckle patterns. In addition, the OCT simulator is equipped with a physically accurate mathematical model of the OCT noise that reflects the spatial properties of shot noise, relative intensity noise (RIN), and non-optical noise [ 11 ] . Therefore, the effects of noise in DOCT imaging can also be investigated using the simulation framework. The performance of our simulation framework is demonstrated by conducting two example studies to investigate the relationships between the DOCT signals and the scatterers’ motion speed, noise, and dynamic-scatterer ratios (i.e., the occupancy of the dynamic scatterers). An open source implementation of the simulator written in Python 3.10.13 with NumPy v1.24.3 and CuPy v12.3.0, and can be found at https://github.com/ComputationalOpticsGroup/COG-dynamic-OCT-contrast-simulation-library [ 12 ] . 2 Simulation framework 2.1 Modeling of intracellular/intratissue dynamics According to a literature survey, seven intracellular/intratissue activity types have been considered including both active [ 13 , 14 , 15 ] and passive [ 13 , 14 , 16 ] transports (for proteins), cyclosis (for organelles) [ 17 ] , the motion of dissociated floaters (for organelles) [ 18 ] , intracellular jiggling (for organelles) [ 19 ] , cell migration (for cells) [ 20 ] , and blood flow (for cells) [ 21 , 22 ] . For each of these activities, one of three types of intracellular and intratissue scatterers, including proteins, organelles and cells, are considered. In addition to these activity types, the typical diameters and masses [ 23 , 24 , 25 , 26 , 27 , 28 ] , the speed and duration of motion, and/or the diffusivity of each of the scatterer types are summarized in Table 1 . Figure 1: Summary of intracellular/intratissue activities and mathematical models of the intracellular/intratissue motions. Seven activity types are included, and each activity type is expressed using one of three types of motion models. In our simulation framework, the scatterer motions related to the intracellular and intratissue activities described above are modeled mathematically using three motion types, including random-ballistic motion, diffusion, and mono-directional translation, as summarized in Fig. 1 . Table 1: Summary of intracellular/intratissue dynamic activities and their properties. The random-ballistic motion models active transport, the motion of dissociated floaters, and cell migration. In this model, all scatterers are in uniform linear motion at the same speed (i.e., the absolute velocity) but move in different randomly defined directions, as illustrated in Fig. 2 (a). This motion is described mathematically as \bm{r}_{j,i+1}=\bm{r}_{j,i}+v\bm{e}_{j}(t_{i+1}-t_{i}), (1) where \bm{r}_{j,i} represents the three-dimensional (3D) location of the j -th scatterer at the i -th time point ( t_{i} ), v is the absolute velocity of the motion, \bm{e}_{j} represents the unit velocity vector of the motion of the j -th scatterer, and (t_{i+1}-t_{i}) is the time interval between the i -th and (i+1) -th time points. Figure 2: Schematic illustrations of the three scatterer motion models. (a) In the random ballistic model, all scatterers are move linearly with the same speed, but the directions of motion are randomly defined for each scatterer. (b) In the diffusion model, the scatterers follow the random walk motion (i.e., Brownian