Seven-dimensional Trajectory Reconstruction for VAMOS++

M. Rejmund, A. Lemasson · 2025

Read Seven-dimensional Trajectory Reconstruction for VAMOS++ by M. Rejmund, A. Lemasson (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-18959.txt.

Introduction

Two authors, Rejmund and Lemasson, built a seven dimensional path rebuild for a magnetic spectrometer. Their paper, from twenty twenty-five, deals with VAMOS++, a large accept tool for ion beams. Its optics bend in a strong nonlinear way, so soft math must rebuild each ion's track to read its stiffness and path length. Old reads take the hit spot as a point. That fails for wide beam spots or gas targets with depth.

Their method adds the reaction spot's three coordinates to the rebuild. Deep neural nets, trained on a built data set, do the math. Readers in nuclear physics get track reads that hold when the source is a cloud, not a point.

Catalog record

CREATORM. Rejmund, A. Lemasson
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-18959

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Seven-dimensional Trajectory Reconstruction for VAMOS++ M. Rejmund, A. Lemasson Abstract The VAMOS++ magnetic spectrometer is characterized by a large angular and momentum acceptance and highly non-linear ion optics properties requiring the use of software ion trajectory reconstruction methods to measure the ion magnetic rigidity and the trajectory length between the beam interaction point and the focal plane of the spectrometer. Standard measurements, involving the use of a thin target and a narrow beam spot, allow the assumption of a point-like beam interaction volume for ion trajectory reconstruction. However, this represents a limitation for the case of large beam spot size or extended gaseous target volume. To overcome this restriction, a seven-dimensional reconstruction method incorporating the reaction position coordinates was developed, making use of artificial deep neural networks. The neural networks were trained on a theoretical dataset generated by standard magnetic ray-tracing code. Future application to a voluminous gas target, necessitating the explicit inclusion of the three-dimensional position of the beam interaction point within the target in the trajectory reconstruction method, is discussed. The performances of the new method are presented along with a comparison of mass resolution obtained with previously reported model for the case of thin-target experimental data. Journal: Nuclear Instruments and Methods in Physics Research Section A Introduction The large angular and momentum acceptance spectrometer VAMOS++ [ 1 , 2 ] is widely utilized in research at beam energies near the Coulomb barrier, particularly in domains such as nuclear structure and reaction mechanism. Its primary function is to provide the isotopic identification of incoming ions of interest, specifically their atomic mass number A and atomic number Z . The key observable provided by the magnetic spectrometer is the magnetic rigidity B\rho of the ion, which is determined based on the dispersive action of the magnetic dipole. The atomic mass number A can then be calculated by combining the magnetic rigidity B\rho with measurements of the ion’s velocity v , the trajectory length between the beam interaction point and the focal plane of the spectrometer l , and the total energy E_{tot} for the detected ions. For further details, refer to Ref. [ 3 ] . The atomic number Z can be obtained by correlating the energy loss \Delta E with the total energy E_{tot} and the atomic charge state q by combining the total energy E_{tot} , B\rho and v . The large angular and momentum acceptance of the VAMOS++ spectrometer is associated with highly nonlinear ion optics. The measurement of the magnetic rigidity B\rho and trajectory length between the beam interaction point and the focal plane of the spectrometer l requires the complex measurements of the initial (at the entrance) and final (in the focal plane of the spectrometer) coordinates and the trajectory reconstruction algorithms. The initial coordinates are determined using the dual position-sensitive Multi-Wire Proportional Chamber (MWPC) telescope [ 4 ] , situated at the entrance of VAMOS++. The final coordinates are measured by two large-area position-sensitive MWPCs positioned within the focal plane. Each MWPC provides horizontal and vertical position as well as timing. Several trajectory reconstruction algorithms have been utilized at VAMOS++ [ 3 ] , of which the most advanced and performant is the four-dimensional 4D mapping method, based on the large dimension four-dimensional arrays indexed by the initial and final coordinates. However, this method assumes a point-like beam spot. This presents a limitation in the case of large beam spot size or extended gaseous target volume. One of the upcoming experimental programs at VAMOS++ aims to use a voluminous gas target designed to study fission dynamics. In this case the optical axis of the spectrometer will be rotated relative to the beam axis. Two fission products will be detected in coincidence, one in VAMOS++ and another in the detector analogous to the dual position-sensitive MWPC telescope [ 4 ] positioned at the entrance of VAMOS++. The combination of data obtained from two telescopes and the use of two-body kinematics will enable the determination of the three-dimensional position of the beam interaction point within the target. In this context, it is necessary to incorporate the beam interaction coordinates into the trajectory reconstruction algorithm. The direct extension of the 4D method to account for this is not feasible due to the excessively large dimensions of the matrices, as inferred from Ref. [ 3 ] . The goal of this work was to develop a novel trajectory reconstruction method capable of handling the seven-dimensional highly nonlinear problem. This was achieved by employing artificial deep neural networks, which were trained on the theoretical dataset of ion trajectories calculated by the standard magnetic ray-tracing code. Figure 1: Beam interaction in the gas volume: (a) Standard coordinate system: The coordinate system is defined with the xz plane coinciding with the dispersive plane of the spectrometer. (b) Sectional view in the xz plane at the VAMOS++ entrance: A sectional view of the xz plane at the entrance of VAMOS++ is presented. The origin of the coordinate system corresponds to the intersection of the beam axis and VAMOS++ optical axis. The angle between the optical axis and the beam axis is 15^{\circ} . The total gas volume and the beam-gas interaction volume are indicated by hatched and grey areas, respectively. An illustration of an outgoing ion originating from the beam-gas interaction is also provided. Figure 2: Aberrations of the VAMOS++ spectrometer with variable horizontal interaction position: The calculated angle, \theta_{f} , as a function of the position, x_{f} , at the image focal plane of VAMOS++ demonstrates the effects of aberrations in both position and angle. The figure presents the final trajectories for varying relative rigidity, \delta=B\rho/B\rho_{0} , set to 0.94 , 0.98 and 1.00 , horizontal angle, \theta_{i} , spanning from -90 to 90 mrad in increments of 30 mrad, horizontal position, x_{i} , set to -10, 0, and 10 mm, vertical and longitudinal positions, y_{i} and z_{i} , both set to 0 mm, and vertical angle, \phi_{i} , set to 0 mrad. Experiments with extended beam interaction volume The details of the standard coordinate system employed with VAMOS++ are presented in Fig. 1 (a). The horizontal xz plane corresponds to the dispersive plane of the spectrometer. At the entrance of the spectrometer, in the VAMOS++ coordinate system, the z axis is parallel to the optical axis of the spectrometer and is designated by the indexes i . The VAMOS++ focal plane coordinate system is typically rotated about the y axis by 45^{\circ} with respect to the coordinates at the entrance and translated to the focal plane following the deviation of the nominal trajectory. It is denoted by the indexes f . The coordinates indexed with b refer to the beam coordinate system, in which the z axis is parallel to the beam axis. The experimental setup is depicted in Fig. 1 (b), which presents a sectional view of the gas target volume in the horizontal xz plane. The angle between the optical axis and the beam axis is 15^{\circ} . For experiments involving a thin target, the beam spot is positioned at (x_{i},y_{i},z_{i})=(0,0,0) and typically has a diameter of \sigma(x_{i})=0.50 mm and \sigma(y_{i})=0.65 mm [ 4 ] . The hatched area represents the total gas volume, while the gray

Read the complete text