Measurements on Time Resolution of BGO, PWO and BSO Crystals

Zhiyu Zhao, Dejing Du, Yong Liu, Jiyuan Chen, Junfeng Chen, Fangyi Guo, Shu Li, Baohua Qi · 2025

Read Measurements on Time Resolution of BGO, PWO and BSO Crystals by Zhiyu Zhao, Dejing Du, Yong Liu, Jiyuan Chen, Junfeng Chen, Fangyi Guo, Shu Li, Baohua Qi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-16880.txt.

Introduction

Zhiyu Zhao and co-authors time test crystals for a future collider eye in a 2025 paper. A fine crystal calorimeter is planned for the Circular Electron Positron Collider, and sharp timing helps sort its events. The team paired three crystals, BGO, PWO, and BSO, with silicon light sensors.

Beam tests at CERN and DESY set the units under pions and electrons alike. An exponential fit with a set fraction rule gave the best time marks. Of like sized crystals, PWO timed best on its fast rise, with BGO and BSO close behind. Long BGO bars held even timing along their span, sharp under heavy showers.

Catalog record

CREATORZhiyu Zhao, Dejing Du, Yong Liu, Jiyuan Chen, Junfeng Chen, Fangyi Guo, Shu Li, Baohua Qi
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE33 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-16880

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Measurements on Time Resolution of BGO, PWO and BSO Crystals Zhiyu Zhao, Dejing Du, Yong Liu, Jiyuan Chen, Junfeng Chen, Fangyi Guo, Shu Li, Baohua Qi Abstract A high-granularity crystal calorimeter (HGCCAL) has been proposed for the future Circular Electron Positron Collider (CEPC). This study investigates the time resolution of various crystal–Silicon Photomultiplier (SiPM) detection units for HGCCAL, focusing on Bismuth Germanate (BGO), Lead Tungstate (PWO), and Bismuth Silicon Oxide (BSO) crystals. Beam tests were conducted using 10 GeV pions at CERN and 5 GeV electrons at DESY, enabling systematic comparisons of timing performance under both minimum ionizing particle (MIP) signals and electromagnetic (EM) showers. Three timing methods—constant fraction timing (CFT) with sampled points, linear fitting, and exponential fitting—were evaluated, with an exponential fit combined with a 10% constant fraction providing the best time resolution. Measurements of crystal units with different dimensions revealed that both scintillation light yield and signal rise time influence timing performance. Among similarly sized crystals, PWO exhibited the best time resolution due to its fast signal rise time, while BGO and BSO demonstrated comparable timing performance. For long BGO bars (40 cm and 60 cm), the time resolution remained uniform along their length, achieving approximately 0.75 ns and 0.95 ns for MIP signals. Under intense EM showers, both bars reached a timing resolution of approximately 200 ps at high amplitudes. And the presence of upstream pre-shower layers can introduce additional timing fluctuations at similar amplitudes. [type=editor] keywords Crystal scintillator ,BGO ,PWO ,BSO ,Time Resolution ,SiPM ,Electromagnetic Shower ,Calorimeter ,Higgs Factory ,CEPC ,Beam Test † † corresponding: Corresponding author 1 Introduction The Circular Electron Positron Collider (CEPC) [ 1 , 2 ] is a proposed next-generation electron-positron collider designed to function as a Higgs factory, aiming for precise measurements of the Higgs boson, W/Z bosons, top quark, and potential new physics beyond the Standard Model. To achieve high jet energy resolution, a high-granularity calorimeter based on the particle-flow algorithm (PFA) has emerged as a leading option. Crystal calorimeters have demonstrated exceptional performance in experimental particle physics, with notable examples including the CMS Electromagnetic Calorimeter (ECAL) [ 3 ] , which played a crucial role in the discovery of the Higgs boson [ 4 ] at the Large Hadron Collider (LHC); the BGO electromagnetic calorimeter [ 5 ] in the L3 experiment [ 6 ] at CERN’s Large Electron-Positron Collider (LEP) [ 7 ] , which contributed significantly to precision electroweak measurements; and ECALs employed in flavor physics experiments such as BaBar [ 8 ] , Belle II [ 9 , 10 ] , and BESIII [ 11 ] . A novel approach, the High-Granularity Crystal Calorimeter (HGCCAL) [ 12 , 13 ] , has been proposed to achieve excellent electromagnetic energy resolution while maintaining compatibility with the PFA [ 14 ] for CEPC. HGCCAL features a homogeneous structure with Silicon Photon Multipliers (SiPMs) as the baseline readout sensors, and dedicated research and development (R&D) efforts have been initiated to advance this concept. Among the various high-density scintillating crystals evaluated for HGCCAL, Bismuth Germanate (BGO) [ 15 ] has been selected as the baseline option due to its high intrinsic light yield, making it highly efficient in detecting electromagnetic particles. Additionally, the technology for growing long BGO bars has been well-established and demonstrated. In addition to BGO, Lead Tungstate (PWO) [ 16 ] and Bismuth Silicon Oxide (BSO) [ 17 ] crystals are also being actively studied due to their distinct advantages. PWO crystals offer a significantly fast scintillation response, improving timing performance, though at the cost of a lower light yield compared to BGO. Meanwhile, BSO, as a relatively new scintillator material, provides a moderate light yield, a faster scintillation decay time, and is more cost-effective than BGO. The choice of crystal material directly impacts calorimeter performance, particularly in energy and time resolution, making the evaluation of the basic crystal detection unit essential for optimizing HGCCAL. Time resolution is a fundamental parameter in detector performance, determining the precision with which the detector measures the arrival time of a particle. High time resolution is crucial for distinguishing closely spaced events, reducing background noise, and enhancing particle identification and energy measurement accuracy. In the context of the CEPC and HGCCAL, superior time resolution improves the reconstruction of electromagnetic showers, leading to enhanced energy measurement precision and particle identification capabilities. Time resolution is influenced by various detector components, including the intrinsic properties of scintillating crystals, the performance of SiPMs, and the electronic readout system. This study evaluates the time resolution of crystal-SiPM detection units using BGO, PWO, and BSO crystals of different dimensions. Through a series of beam tests with both minimum ionizing particles (MIPs) and high-energy electrons, we investigate factors affecting time resolution, including crystal dimensions, scintillation properties, and electronics. Specifically, we examine the effectiveness of different timing methods, the uniformity of time response along long BGO crystal bars, and the impact of electromagnetic shower development on timing performance. The results provide valuable insights for optimizing crystal calorimeter designs for CEPC. This study focuses on evaluating the time resolution of crystal-SiPM detection units using BGO, PWO, and BSO crystals of different dimensions. Through a series of beam tests involving both minimum ionizing particles (MIPs) and high-energy electrons, we have investigated the factors influencing time resolution, including crystal dimensions, scintillation properties, and electronics. Specifically, we examine the overall effectiveness of different timing methods, the uniformity of time response along long BGO crystal bars, and the impact of electromagnetic shower development on timing performance. The results provide valuable insights into the optimization of crystal calorimeter designs for CEPC. 2 Experiment description The time resolution of various crystal scintillators was measured and compared through beam tests. Key factors affecting the MIP time resolution of individual crystals, such as crystal dimensions, timing techniques, and the intrinsic time resolution of the electronics, were investigated. Additionally, the time resolution of crystal units under electromagnetic showers was examined. 2.1 Crystal samples s Figure 1: (a) BGO, PWO and BSO crystal scintillator with various sizes, wrapped in ESR and aluminum reflective films. (b) The basic Crystal-SiPM detection unit. Table 1: The tested crystal samples, along with their quantities and dimensions. Crystal Quantity Dimension (cm 3 ) BGO 6 1 \times 1 \times 4, 1 \times 1 \times 8, 1 \times 1 \times 16, 1 \times 1 \times 24, 1 \times 1 \times 40, 1.5 \times 1.5 \times 60 PWO 4 1 \times 1 \times 2, 1 \times 1 \times 4, 1 \times 1 \times 8, 1 \times 1 \times 16 BSO 1 1 \times 1 \times 7 The crystal samples measured are listed in Table 1 . Three types of crystals produced by SIC-CAS were tested: BGO, PWO, and BSO. Among these, the BGO crystal exhibits the highest intrinsic light yield but the slowest scintillation decay time, while the PWO crystal has the fastest scintillation decay time but the lowest light yield. The BSO crystal demonstrates moderate performance. As light yield and scintillation decay time are the two primary factors influencing time resolution, the analysis of the crystals’ time resolution will focus on these two aspects. The crystal lengths ranged from 2 cm to 60 cm. Except for a single 60 cm-long BGO crystal with a cross-sectional

Read the complete text