Measurement of the Quantum Efficiency of Electrode Materials for VUV Photons in Liquid Xenon
S. Kazama, N. Aoyama, Y. Itow, M. Kobayashi · 2025
Read Measurement of the Quantum Efficiency of Electrode Materials for VUV Photons in Liquid Xenon by S. Kazama, N. Aoyama, Y. Itow, M. Kobayashi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-14819.txt.
Introduction
Shingo Kazama, Naoki Aoyama, Yoshitaka Itow, and Masatoshi Kobayashi measure how readily electrode materials in xenon detectors give off electrons when lit by ultraviolet light, in a 2025 paper. Liquid xenon chambers hunt light dark matter through tiny signals. Stray electrons knocked off electrodes by the chamber's own light can fake those signals.
Working in liquid xenon, the team measured quantum efficiency for platinum, stainless steel, and aluminum coated with magnesium fluoride. The coated aluminum was quietest, about four times less prone to give off electrons than the standard steel at the wavelength in question. Such a choice could cut a stubborn background. That would extend the chambers' reach to lighter dark matter.
Catalog record
| CREATOR | S. Kazama, N. Aoyama, Y. Itow, M. Kobayashi |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 18 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-14819
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measurement of the Quantum Efficiency of Electrode Materials for VUV Photons in Liquid Xenon S. Kazama, N. Aoyama, Y. Itow, M. Kobayashi Abstract Light dark matter searches using ionization signals in dual-phase liquid xenon (LXe) time projection chambers (TPCs) are limited by low-energy ionization backgrounds, including those from the photoelectric effect on the electrodes. To address this, we measured the quantum efficiency (QE) of various electrode materials for vacuum ultraviolet (VUV) photons in LXe, including platinum (Pt), stainless steel (SUS304), and magnesium fluoride (MgF 2 )-coated aluminum (Al). Our results show that MgF 2 -coated Al exhibits the lowest QE among the tested materials. The QE for VUV photons with a mean wavelength of 179.5 nm was measured to be ( 7.2 ± 2.3 ) × 10 − 5 (7.2\pm 2.3)\times 10^{-5} , corresponding to a reduction by a factor of 4.4 compared to SUS304, a commonly used electrode material in direct dark matter experiments with LXe. These findings suggest that employing low-QE electrodes can help mitigate photoelectric-induced backgrounds, potentially improving the sensitivity of LXe TPCs in light dark matter searches. 1]Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya, Aichi, 464-8601, Japan 2]Institute for Space-Earth Environmental Research, Nagoya University, Nagoya, Aichi, 464-8601, Japan PTEP-subject dark matter, liquid xenon, low background † † preprintnumber: XXXX-XXXX 1 Introduction Dual-phase time projection chambers (TPCs) that utilize both liquid and gaseous xenon are at the forefront of dark matter searches. These detectors have set the most stringent constraints on the interaction cross-section between Weakly Interacting Massive Particles (WIMPs) and ordinary matter [ Aprile et al.(2023a)Aprile et al. , Aalbers et al.(2023)Aalbers et al. , Bo et al.(2025)Bo et al. ] . By detecting primary scintillation (S1) and ionization signals via the proportional electroluminescence mechanism (S2), TPCs enable three-dimensional event reconstruction, which facilitates fiducialization of the active detector volume and suppression of radioactive backgrounds from detector materials and surface contaminants. Furthermore, the charge-to-light ratio (S2/S1) provides an effective means of discriminating nuclear recoil signals from electronic recoils based on differences in ionization density. While the combination of S1 and S2 signals offers strong sensitivity to WIMPs above 5 GeV/c 2 , the sensitivity to low-mass WIMPs is limited due to the relatively low detection efficiency of S1 signals. Recent studies have demonstrated that liquid xenon (LXe) TPCs are highly sensitive to single ionization electrons as a result of proportional electroluminescence amplification in gaseous xenon (GXe), leading to a single-electron (SE) detection efficiency of nearly 100 \% [ Aprile et al.(2019)Aprile et al. , Aprile et al.(2022)Aprile et al. , Aprile et al.()Aprile et al. , Li et al.(2023)Li et al. ] . Leveraging this capability, SE-based analyses that do not require an S1 signal could significantly enhance sensitivity to sub-GeV WIMPs. However, these analyses have been found to result in increased rates of low-energy electron backgrounds [ Aprile et al.(2019)Aprile et al. , Aprile et al.(2022)Aprile et al. , Aprile et al.()Aprile et al. , Li et al.(2023)Li et al. , Akerib et al.(2020a)Akerib et al. ] , originating from various sources, including impurities, delayed electron emission, and photoionization effects. Among these background contributions, photoionization and the photoelectric effect of LXe scintillation photons on the electrodes represent potential sources of low-energy electrons. These effects could contribute to the overall background level in SE-based searches. Therefore, understanding and mitigating these processes through the use of electrode materials with reduced quantum efficiency (QE) could provide an incremental improvement in sensitivity to low-mass WIMPs. In this study, we developed a dedicated experimental setup to measure the QE of various electrode materials for vacuum ultraviolet (VUV) photons in LXe and evaluated their potential for application in future LXe experiments such as DARWIN and XLZD [ Aalbers et al.(2016)Aalbers et al. , Aalbers et al.()Aalbers et al. ] . 2 Electrode Materials In this study, stainless steel (SUS304), platinum (Pt), and magnesium fluoride (MgF 2 )-coated aluminum (Al) were selected as candidate electrode materials, as summarized in Table 1 . Stainless steel is widely used as an electrode material in current LXe experiments such as XENONnT [ Aprile et al.(2023b)Aprile et al. ] , PandaX [ Bo et al.(2025)Bo et al. ] , and LZ [ Akerib et al.(2020b)Akerib et al. ] . It was chosen as the reference material in this study due to its well-established performance in these applications. For our measurements, an electropolished SUS304 plate with dimensions of 12 mm \times 12 mm and a thickness of 2 mm was used. Platinum was selected as a candidate electrode material due to its high work function, the highest among common metals [ Herbert(1977) ] , making it a promising choice for suppressing photoemission-induced backgrounds. A 100 nm-thick Pt layer was deposited via sputtering onto a 12 mm \times 12 mm quartz glass substrate with a thickness of 2 mm. To enhance adhesion between the quartz glass and Pt, an intermediate chromium (Cr) layer with a thickness of 10 nm was also deposited. MgF 2 -coated Al was chosen for its unique combination of reflective and insulating properties, which may contribute to a lower QE. This material is commonly used as a reflective flat mirror for VUV light [ Bajpai1 et al.(2024)Bajpai1 et al. ] , and the one produced by SIGMAKOKI (TFA-10S03-10) was used in this study. In this configuration, a 100 nm-thick Al layer was first vapor-deposited onto a borosilicate glass substrate (12 mm \times 12 mm, 3 mm thick), followed by the vapor deposition of a 137 nm-thick MgF 2 layer on top. It is important to note that both the Pt and MgF 2 layers are sufficiently thick, ensuring that any photoelectrons generated in the underlying Cr or Al layers do not reach the surface and are therefore not extracted. This minimizes contributions to the measured QE from secondary effects. Table 1 : Electrode materials investigated in this study Property SUS304 Pt MgF 2 -coated Al Thickness 2 mm 100 nm 137 nm (MgF 2 ) Intermediate layer N/A 10 nm (Cr) 100 nm (Al) Substrate SUS304 Quartz glass Borosilicate glass Deposition method N/A Sputtering Vapor deposition Surface treatment Electropolished N/A N/A 3 Experimental Setup and Operation 3.1 Experimental Setup An experimental setup was developed at Nagoya University to measure the QE of electrode materials for VUV photons in LXe. The setup, illustrated in Fig. 1 , consisted of two primary components: one for determining the number of incident photons ( N_{\mathrm{ph}} ) and the other for estimating the number of emitted electrons ( N_{\mathrm{e}} ) via the photoelectric effect. The QE is then calculated as \mathrm{QE}=\frac{N_{\mathrm{el}}}{N_{\mathrm{ph}}} (1) A 110 W deuterium lamp (Hamamatsu photonics, L15904) served as the VUV light source, producing a broad spectrum ranging from 115 to 400 nm. The lamp’s MgF 2 window allows VUV photons to pass without significant attenuation. The spectral range was limited to the VUV region by two narrow bandpass filters (Pelham Research Optical, 172-NB-1D). A VUV lens (eSource Optics, CF 1220LCX) was used to focus the light beam onto the fibers. The resulting wavelength distribution, shown in Fig. 2 , has a mean wavelength of 179.5 nm with a standard deviation of 7.4 nm, which closely matches the mean wavelength of