Capillary-driven thinning of DNA solutions
Vincenzo Calabrese 1,∗, Silvia Nardone 1,2, Amy Q. Shen 1, Simon J. Haward 1 · 2025
Read Capillary-driven thinning of DNA solutions by Vincenzo Calabrese 1,∗, Silvia Nardone 1,2, Amy Q. Shen 1, Simon J. Haward 1 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-14145.txt.
Introduction
Vincenzo Calabrese, Silvia Nardone, Amy Shen, and Simon Haward study how DNA solutions thin into threads in a paper from 2025. When a drop stretches, the thread shrinks in an exponential pattern that matters for biology and industry. Using clean solutions of semi-flexible DNA, the team validates a model that accounts for every strand length in the mixture. For such chains, the thinning rate selects itself by a different route than in floppy systems, and the longest strand does not set the pace.
Catalog record
| CREATOR | Vincenzo Calabrese 1,∗, Silvia Nardone 1,2, Amy Q. Shen 1, Simon J. Haward 1 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-14145
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Capillary-driven thinning of DNA solutions Preprint: APS/123-QED Vincenzo Calabrese 1,∗, Silvia Nardone 1,2, Amy Q. Shen 1, Simon J. Haward 1 Abstract Capillary thinning of polymeric fluids is central to biological and industrial processes, yet the mechanisms governing thinning dynamics remain unresolved, especially for semi-flexible polymers. Using ideal solutions of semi-flexible DNA, we validate a predictive model for exponential capillary thinning that accounts for each polymer in the molecular weight distribution. For semi-flexible polymers, self-selection of the exponential time constant occurs by a fundamentally different mechanism than for highly flexible systems, and is not simply governed by the longest polymer relaxation time. Sufficiently slender fluid filaments self-thin under the action of surface tension. This phenomenon known as capillary-driven thinning is ubiquitous in both biological and industrial processes involving fluid breakup McKinley 2005 ; Keshavarz et al. 2016 ; Rühs et al. 2021 ; Zinelis et al. 2024a . For instance, in the printing industry, capillary-driven thinning drives the formation of ink droplets, while during sneezing or coughing, it dictates the size of mucus droplets, affecting the transmission of viral diseases Dhand and Li 2020 . During capillary-driven thinning of fluid filaments, the radial squeezing of the filament by surface tension generates a uniaxial extensional flow. For Newtonian fluids (water, honey), the physics of capillary-driven thinning is well understood, as thinning is controlled by a balance of surface tension against viscous and inertial forces Papageorgiou 1995 ; McKinley 2005 ; McKinley and Tripathi 2000 . For more complex fluids such as polymer solutions, additional elastic forces may come into play, and the filament thinning dynamics becomes intimately linked to the orientational dynamics of the polymer in the extensional flow field. These coupled dynamics lead to the attractive possibility of extracting rheological properties (viz. characteristic polymer “relaxation times”) from straightforward time-resolved measurements of the width of the thinning polymeric filaments McKinley 2005 ; Campo-Deaño and Clasen 2010 ; Dinic and Sharma 2020 ; Gaillard et al. 2024a ; Gaillard et al. 2024b ; Zinelis et al. 2024b ; Aisling et al. 2024 . However, significant questions remain over how the coupling between thinning and polymeric dynamics depends on factors such as polymer stiffness or flexibility, architecture, concentration in solution, molecular weight, and polydispersity of the molecular weight. Figure 1: Base pair (bp) distribution for (a) \lambda , (b) T4 and (c) ct DNA. (d-f) Snapshots of the capillary-driven thinning of DNA solutions. (d) \lambda at c/c^{*}=1.8 , (e) T4 at c/c^{*}=1.7 , and (f) ct-DNA at c/c^{*}=2.2 . The reference time t_{R} is taken as the time t when the filament diameter D=0.1 mm. Strong extensional flow developed during the capillary-driven thinning of polymeric fluids leads to stretching and alignment of polymer chains and the appearance of an elastocapillary (EC) regime Bazilevsky et al. 1990 ; Entov and Hinch 1997 ; Clasen et al. 2006 ; Sattler et al. 2007 ; Juarez and Arratia 2011 . The EC regime is characterized by an exponential decrease of the diameter at the neck of the filament, D , with time, t , according to the time constant \tau_{EC} as, D\sim\mathrm{exp}(-t/\tau_{EC}). (1) The most controversial aspect is how the fluid self-selects the elastocapillary time constant, \tau_{EC} , based on polymer conformation and concentration. The prevailing interpretation is based on the Oldroyd-B constitutive model, which assumes polymer chains to be infinitely extensible. This model asserts that \tau_{EC} is determined by the longest polymer relaxation time, \tau\equiv\tau_{EC}/3 . However, it is increasingly evident that this relationship does not hold universally Calabrese et al. 2024a ; Gaillard et al. 2024a ; Zinelis et al. 2024b ; Gaillard et al. 2024b . Experimental and numerical studies have shown that the Oldroyd-B model becomes progressively less accurate in describing polymer dynamics in the EC regime as polymer stiffness increases Zinelis et al. 2024b ; Calabrese et al. 2024a . Thus, for semi-flexible polymers (e.g., polyelectrolytes and most biopolymers) cases where \tau_{EC}/3\ll\tau have been reported Calabrese et al. 2024a . Despite intense experimental efforts to study semi-flexible polymers in capillary-driven flows, these studies have provided limited understanding due to the use of polydisperse polymers with unknown size distributions and uncertain average molecular weight ( Mw ) Dinic and Sharma 2020 ; Jimenez et al. 2018 ; Jimenez et al. 2020 ; Calabrese et al. 2024a ; Sattler et al. 2007 . Figure 2: Filament diameter D and extension rate \dot{\varepsilon} as a function of time t-t_{R} (top and bottom raw, respectively) for the \lambda (a, b), T4 (c, d) and ct-DNA (e, f). The dashed lines in (a, c, e) indicate the fit to eqn. 1 and in (b, d, f) the corresponding \dot{\varepsilon}_{EC} . For clarity, only representative fluids are shown. The insets in (b), (d), and (f) show snapshots of the respective DNA solutions at the highest measured concentrations, scale bar is 0.2 mm. In panel (d), the peak extension rate \dot{\varepsilon}_{p} is highlighted. In this Letter, we tackle this problem by employing monodisperse DNAs as a model semi-flexible polymer to establish a fundamental understanding of how Mw and polymer concentration influence \tau_{EC} . To extrapolate our findings to more complex systems, we also investigate well-characterized bidisperse and polydisperse DNA solutions. We propose a simple model that captures the experimental observations and highlights that, in solutions of semi-flexible polymers, the time constant \tau_{EC} accounts for the time scale contribution from each DNA size present in the population. We use monodisperse \lambda -DNA (Thermo Fisher) and T4-DNA (Nippon Gene) with 48.5\times 10^{3} and 166.0\times 10^{3} base pairs (bp), corresponding to Mw\simeq 32 and 108 MDa, respectively. As polydisperse DNA we use calf thymus DNA, ct-DNA (MP Biomedicals) with a peak size of 20\times 10^{3} bp ( Mw\simeq 13 MDa). The bp-distribution of the tested DNAs was measured using a femto pulse electrophoresis system (Agilent Technologies) (Fig. 1 (a-c)). The samples are prepared by dilution of the DNA stock solutions with a Newtonian aqueous buffer (Tris-EDTA 10 mM Tris-HCl, 1 mM EDTA, pH 8.0), following previous guidelines Harnett et al. 2024 ; Banik et al. 2021 (see Supplemental Material for details ESI ). For each sample, the DNA concentration c and sample homogeneity is determined using a UV-Vis spectrophotometer (Nanodrop, Thermo Fisher) Banik et al. 2021 . For \lambda and T4-DNA, the overlap concentration c^{*}=40 and 21 µg/mL, respectively, is estimated based on simple cubic packing fraction of DNA coils Rubinstein and Colby 2003 ; Brunet et al. 2016 ; Reisner et al. 2012 ; ESI . For polydisperse ct-DNA c^{*}=128 µg/mL is estimated experimentally from rheometric measurements ESI . The self-driven capillary thinning of the fluid filament is measured at 22^{\circ} C using the low-inertia slow retraction method (SRM) implemented on a commercial capillary breakup extensional rheometer (CaBER) device (Haake, ThermoScientific) Campo-Deaño and Clasen 2010 . The fluid is loaded in the 1 mm gap between two coaxial circular plates (with diameter 6 mm). The lower plate is moved downwards using a micro-adjustable stage causing the fluid to undergo capillary-driven thinning. The filament thinning is recorded using a high-speed camera (Phantom Miro 310 at 17000 frame/s) and the minimum filament diameter D is retrieved using a MATLAB routine following the guidelines given in ref. Ng and Poole 2021 . Fig