Degradation-based Energy Management for Microgrids in the Presence of Energy Storage Elements

Satish Vedula · 2025

Read Degradation-based Energy Management for Microgrids in the Presence of Energy Storage Elements by Satish Vedula (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-09028.txt.

Introduction

Satish Vedula, writing alone, proposes an energy management strategy for microgrids that accounts for battery wear in a 2025 paper. Solar plants lack the natural steadiness of spinning generators, so demand surges after sunset strain the grid. Batteries can respond fast, but they wear out faster than generators, which makes their use a trade-off.

The proposed method plans energy use with a predictive model that prices in battery degradation while meeting demand. Simulations tested it on several physical systems, including shipboard power systems. The study also simulates faults in the solar-side equipment to probe the risks they add. The author aims for grids that are more robust and resilient, with fewer failures driven by worn components.

Catalog record

CREATORSatish Vedula
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE97 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-09028

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Degradation-based Energy Management for Microgrids in the Presence of Energy Storage Elements Satish Vedula Abstract Department of Electrical and Computer Engineering, the Center for Advanced Power Systems, Florida State University E-mail: {svedula}@fsu.edu 1 Abstract Integration of Inverter-based Resources (IBRs) such as solar-powered plants which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG) based sources presents a new challenge in the form of analyzing the grid stability under their presence. With the increasing penetration of the IBRs into the traditional grid, the non-renewable means of power generation which are dependent on coal, and natural gas is reducing drastically during the presence of power generated through renewable sources. For example, solar power is available for approximately from 9 AM-5 PM. However, the result of the rise in power consumption after 6 PM and the reverting back to the non-renewable source of power generation during that period puts immense stress on the grid, testing the ramp limitations of the SGs. Failure to meet the required power demand due to SG ramp limitations leads to failure of the power grid and other catastrophes. Numerous mitigation techniques exist in order to address the ramping issues with adding the energy storage elements (ESE) to the grid being one. ESEs have higher ramping capabilities compared to the traditional SGs. Also, the ESEs can store the energy and supply it to the grid when required making them extremely responsive to high ramp situations. However, the rate of degradation of the ESEs is faster than the SGs. Failure to adaptively manage the degradation of the ESEs might lead to the risk of sudden failure and eventually trigger a grid collapse. This raises an important issue of addressing the degradation of the ESEs while meeting the required power demand objectives and constraints. This work proposes a battery degradation-aware model predictive energy management strategy and it is tested via a numerical simulation on multiple physical systems such as Shipboard Power Systems (SPS) and Hybrid Electric vehicles (HEV). Moreover, the risk arising due to the fault in the IBR is also studied by means of a numerical simulation. Overall, the goal of this study is to make the existing power grid more robust, resilient, and risk-free from component degradation and eventual failures. 2 Introduction and Background 2.1 Motivation Feedback Control is the technique that drives the mechanical, electrical, or biological systems towards equilibrium and maintains the system at equilibrium [ 1 ] . Origin of control dates back to ancient Egypt. Egyptians first designed a water clock around 1500 B.C Greeks improvised it around 300 B.C, and they called it float regulator. The main goal of the float regulator designed by the Greeks was to maintain a constant water level in the tank. Present-day ball in flush toilets works on a similar principle. Ancient Greeks also deployed this in various applications such as automatic wine dispensers. Its principle is the modern-day equivalent of open-loop control. This concept of an open loop-controlled water clock soon moved across the world. The Chinese and the Korean water clocks were designed using similar principles. During 1200A.D , Arab engineers further improvised the existing float regulator and introduced an on/off control. A major breakthrough in the field of controls was during the Industrial Revolution. Advanced mills, boilers, and steam engines were developed during this period. These advancements required new control methods, thus, temperature control, pressure control, etc were introduced. James Watt invented the steam engine in 1769 A.D. One prominent feedback control introduced by James Watt in 1788 A.D called fly-ball governor was used in steam engine speed regulation. The difference between the actual speed and the desired speed (error signal) dictated the amount of steam output to the engine [ 2 ] . British astronomer G.B. Airy in 1840A.D developed a closed loop feedback for a telescope that automatically adjusted the telescope concerning earth rotation. This gave birth to mathematical control theory. He was the first to discover that improper design of closed-loop systems will lead to oscillations and instability. In 1868 A.D. James Maxwell published a paper titled On Governors [ 3 ] . In this paper, Maxwell remarked that every physical system can be expressed as a differential equation. He analyzed fly-ball governors’ stability by expressing it in differential equation form. Maxwell successfully presented the stability conditions for systems up to third order. Maxwell linearized the differential equations and formulated the characteristic equation to determine the roots of the system. The stability condition proposed was the possible parts of all the roots shall be negative [ 2 ] . He was unable to present the stability conditions for the fifth and higher order system completely and thus left it for future research enthusiasts. In 1877 A.D. English mathematician Edward J Routh and In 1895 German mathematician Adolf Hurwitz independently formulated a numerical method to determine the stable roots of the characteristic equation. This method became widely popular and is used even today in stability analysis under the name of Routh Hurwitz Criteria . Even though many researchers during that time found Maxwell’s paper extremely hard to interpret, it was Norbert Wiener who highlighted the significance of Maxwell’s paper in 1948 A.D. In 1892 A.D. a Russian mathematician named A.M. Lyapunov studied the stability of nonlinear differential equations using energy functions. The work of Lyapunov was introduced to the Western world during the 1960s by a Hungarian-American mathematician named R.E. Kalman. Lyapunov’s work is pivotal in the development of Modern Control Theory . While the control development was taking place during the late 19^{th} century, during the same time frame researchers like Thomas Edison and Nikola Tesla were making developmental strides in the development of the Alternating Current (AC) and Direct Current (DC). Edison and Tesla had differing views on electricity distribution, with Edison advocating for DC and Tesla for AC. Edison famously promoted the use of DC through public demonstrations. The rivalry between Edison’s General Electric Company and George Westinghouse’s company, which backed Tesla’s AC system, intensified the competition between the two inventors. Tesla’s work on AC power laid the groundwork for the modern electrical grid, which is based predominantly on AC distribution. The development of the first modern power grid is often credited to systems that emerged in the late 19 th and early 20 th centuries. Here are a few notable examples: • Pearl Street Station (1882) : This was the first centralized power plant in the United States, located in lower Manhattan, New York City. Thomas Edison’s Edison Illuminating Company built it and began operations on September 4, 1882. The Pearl Street Station provided direct current (DC) electricity to customers within a one-mile radius using underground conductors. • London Electric Supply Corporation (1882) : In the UK, the London Electric Supply Corporation (LESC) established one of the earliest central power stations in the world. It was located in Deptford, London, and began supplying electricity to street lamps and a few businesses in 1882. The system used both AC and DC, with AC for long-distance transmission and DC for local distribution. The late 20 th century saw the rapid growth of the solid-state electronic industry which led foundation for the modern power inverters. Inverters were primarily

Read the complete text