R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II
Xiyang Wang, Hongyu Zhang, Shiming Zou, Zibing Bai, Deqing Fang, Kairui Huang, Ziyu Liu, Yugang Ma, Weiqi Meng, Ting Wang, Xiaolong Wang, Shiqing Xie, Mingjie Yang, Junhao Yin, Mingkuan Yuan, Wanyi Zhuang · 2025
Read R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II by Xiyang Wang, Hongyu Zhang, Shiming Zou, Zibing Bai, Deqing Fang, Kairui Huang, Ziyu Liu, Yugang Ma, Weiqi Meng, Ting Wang, Xiaolong Wang, Shiqing Xie, Mingjie Yang, Junhao Yin, Mingkuan Yuan, Wanyi Zhuang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-06128.txt.
Introduction
Xiyang Wang and co-authors report, in a 2025 paper, development work on a detector upgrade for the Belle II particle experiment in Japan. The goal is to time the flight of neutral hadrons, particles that leave no track, so their momentum can be measured directly for the first time in that detector.
The team built cheap plastic scintillators with a partner company and read them out with silicon light sensors. A long sample let light travel well over a meter while keeping timing sharp to about seventy trillionths of a second at its middle. A shorter piece reached even finer timing. The results support the upgrade plan.
Catalog record
| CREATOR | Xiyang Wang, Hongyu Zhang, Shiming Zou, Zibing Bai, Deqing Fang, Kairui Huang, Ziyu Liu, Yugang Ma, Weiqi Meng, Ting Wang, Xiaolong Wang, Shiqing Xie, Mingjie Yang, Junhao Yin, Mingkuan Yuan, Wanyi Zhuang |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-06128
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II Xiyang Wang, Hongyu Zhang, Shiming Zou, Zibing Bai, Deqing Fang, Kairui Huang, Ziyu Liu, Yugang Ma, Weiqi Meng, Ting Wang, Xiaolong Wang, Shiqing Xie, Mingjie Yang, Junhao Yin, Mingkuan Yuan, Wanyi Zhuang Abstract Accurate momentum determination of a neutral hadron, such as a K L K_{L} meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large K L K_{L} and Muon Detector (KLM). We investigate the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conduct research and development of cost-effective plastic scintillators in collaboration with GaoNengKeDi Company, and technology utilizing silicon photomultipliers (SiPMs) arrays. A bulk attenuation length of 120 ± 7 cm 120\pm 7\penalty\ $\mathrm{cm}$ has been achieved with a 135 cm 135\penalty\ $\mathrm{cm}$ -long sample, along with a time resolution of 70 ± 7 ps 70\pm 7\penalty\ $\mathrm{ps}$ at its midpoint. A 50 cm 50\penalty\ $\mathrm{cm}$ -long scintillator demonstrates an exceptional time resolution of 47 ± 2 ps 47\pm 2\penalty\ $\mathrm{ps}$ . These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector. Journal: Nucl. Instrum. Methods A 1 Introduction In particle and nuclear physics experiments, accurately determining the momentum of neutral hadrons, such as K_{L} mesons and neutrons, poses significant challenges. High energy frontier experiments like ATLAS and CMS employ costly hadron calorimeters (HCALs) that achieve energy resolutions \sigma(E)/E of approximately (50-90)\%/\sqrt{E(\hbox{GeV})} [ 1 , 2 ] . On the other hand, intensity frontier experiments such as BaBar [ 3 ] , Belle [ 4 ] , Belle II [ 5 ] , and BESIII [ 6 ] do not use HCALs for measuring the energy of neutral hadrons with momenta ranging from 1-5\penalty\ \hbox{GeV}/c . This is primarily due to the limited energy resolution that can be achieved by HCAL. As a super B-factory experiment, the Belle II experiment was designed to explore new physics at the forefront of high-luminosity collisions and improve the precision of measurements for Standard Model parameters [ 7 ] . The Belle II spectrometer has a huge outermost subdetector, the K_{L} and Muon Detector (KLM) [ 5 ] . In the Conceptual Design Report (CDR) for the Belle II upgrade, we proposed enhancing the KLM system with a new capability: Time-of-Flight (TOF) measurements [ 8 ] . This upgrade will enable the direct determination of momentum with a resolution of approximately 10% for a long-lived neutral hadron, such as a K_{L} meson or a neutron, based on its velocity. However, implementing TOF technology poses a significant challenge due to the need for cost-effectiveness, given the large volume and number of readout channels of the KLM system. Traditional TOF detectors primarily employ two technological approaches. The first approach utilizes plastic scintillators coupled with photodetectors, such as photomultiplier tubes (PMTs) or silicon photomultipliers (SiPMs). The PMT method has been successfully implemented in TOF systems such as the Belle TOF with a time resolution of 100\penalty\ $\mathrm{ps}$ [ 4 ] and the BESIII barrel TOF with a resolution of 80\penalty\ $\mathrm{ps}$ using two scintillator layers [ 6 ] . PMTs have inherent limitations, including their large physical size, which creates dead zones, and the requirement for a high-voltage (HV) system operating at over 1000\penalty\ $\mathrm{V}$ . The inherent transit time spread of PMTs poses a significant challenge in achieving high time resolution (HTR). In addition, the use of such scintillators and PMTs also incurs significant costs. The second approach utilizes multi-gap resistive plate chambers (MRPCs), as in experiments such as STAR [ 9 ] , ALICE [ 10 ] , and the upgraded endcap TOF of BESIII [ 11 ] . While MRPCs can achieve an HTR of 50-60\penalty\ $\mathrm{ps}$ , they suffer from notable drawbacks, including complex structures requiring gas flow systems, susceptibility to gas contamination (e.g., \rm C_{2}H_{2}F_{4}/C_{4}H_{10}/SF_{6} ), and a large number of readout channels. Currently, several experiments have successfully implemented SiPMs with small-sized scintillators (length \leq 15\penalty\ $\mathrm{cm}$ ) to construct TOF detectors, achieving time resolutions better than 100\penalty\ $\mathrm{ps}$ , as demonstrated by the PANDA [ 12 ] , AMS-100 [ 13 ] , MEG-II [ 14 , 15 ] and Mu3e [ 16 ] experiments. However, the application of SiPMs with large elongated scintillators remains limited. Key challenges in such implementations include the scintillator’s attenuation length, elevated noise levels in SiPM arrays, and issues associated with slow rise times ( \tau_{\rm rise} ) of the signal pulse. To achieve HTR for the KLM upgrade [ 8 ] , the limitations of TOF technologies using PMTs or MRPCs underscore the need for alternative technologies and materials that balance performance, simplicity, and cost-effectiveness. SiPM-based technology presents a promising solution, though challenges related to large-scale applications must be addressed. In collaboration with us, the GaoNengKeDi Company [ 17 ] has been developing new scintillators for HTR at low cost. Simultaneously, we have been conducting research and development (R&D) on SiPM-based technology for HTR. Through these efforts, we have successfully developed new scintillators and SiPM-based TOF technology for HTR, which are critical for an upgraded KLM to determine the momentum of a long-lived neutral hadron. This paper describes the principle for measuring the momentum of a neutral hadron using an upgraded KLM with HTR, introduces the new scintillators and SiPM-based technologies developed for HTR, and demonstrates their performance. 2 Belle II KLM and its upgrade As the outermost component of the Belle II detector, the KLM is responsible for identifying K_{L} mesons and muons with momenta up to 4.5\penalty\ \hbox{GeV}/c [ 5 ] . As illustrated in Fig. 1 (a), the KLM spans radii from 200\penalty\ $\mathrm{cm}$ to \penalty\ 240\penalty\ $\mathrm{cm}$ in the octagonal barrel region and from 130\penalty\ $\mathrm{cm}$ to 340\penalty\ $\mathrm{cm}$ in the endcaps. The barrel section consists of 15 detector layers interspersed with 14 layers of yoke iron, while each endcap contains 14 detector layers and 14 iron layers. The iron yoke serves a dual purpose: it acts as a magnetic flux return for the solenoid and enables hadronic shower, which is essential for K_{L} detection. The large-surface-area detector panels, approximately 3.1\penalty\ $\mathrm{cm}$ thick, are positioned between 4.7\penalty\ $\mathrm{cm}$ steel plates. Within these panels, the innermost two layers of the barrel and all layers of the endcaps are equipped with extruded scintillator detector modules [ 18 ] . The remaining 13 barrel layers utilize the Belle experiment’s legacy Resistive Plate Chambers. In the scintillator modules, each scintillator strip incorporates a Kuraray Y11(200)MSJ wavelength-shifting (WLS) fiber, which collects photons emitted by the extruded scintillator and guides them to a Hamamatsu (HPK) MPPC S10362-13-050C, a SiPM with a sensitive area of 1.3\penalty\ $\mathrm{mm}$\times 1.3\penalty\ $\mathrm{mm}$ [ 19 ] . Figure 1: (a) The KLM system within the Belle II detector. (b) A hadronic cluster generated by a K_{L} meson in the Belle II virtual reality simulation. Point A illustrates the e^{+}e^{-} collision that produces the K_{L} meson. Point B depicts the K_{L} meson initiating