Attenuation artifact detection and severity classification in intracoronary OCT using mixed image representations

Pierandrea Cancian, Simone Saitta, Xiaojin Gu, Rudolf L.M. van Herten, Thijs J. Luttikholt, Jos Thannhauser, Rick H.J.A. Volleberg, Ruben G.A. van der Waerden, Joske L. van der Zande, Clarisa I. Sánchez, Bram van Ginneken, Niels van Royen, Ivana Išgum · 2025

Read Attenuation artifact detection and severity classification in intracoronary OCT using mixed image representations by Pierandrea Cancian, Simone Saitta, Xiaojin Gu, Rudolf L.M. van Herten, Thijs J. Luttikholt, Jos Thannhauser, Rick H.J.A. Volleberg, Ruben G.A. van der Waerden, Joske L. van der Zande, Clarisa I. Sánchez, Bram van Ginneken, Niels van Royen, Ivana Išgum (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-05322.txt.

Introduction

Pierandrea Cancian and co-authors build a tool that spots and grades artifacts in heart artery images, in a 2025 paper. Intracoronary optical coherence tomography gives sharp views inside vessels. Leftover blood and gas bubbles cause attenuation artifacts that hide key structures. Staff must decide fast whether a scan needs retaking. Extra scans cost time and contrast dye.

Their method mixes image representations to catch the varied look of these artifacts. It both detects artifacts and grades their severity. Trained judges' labels guide the learning process. Reliable grading could limit retakes to the scans that truly need them. Cardiologists gain cleaner images with less patient burden. The approach may transfer to other imaging tasks with messy artifacts.

Catalog record

CREATORPierandrea Cancian, Simone Saitta, Xiaojin Gu, Rudolf L.M. van Herten, Thijs J. Luttikholt, Jos Thannhauser, Rick H.J.A. Volleberg, Ruben G.A. van der Waerden, Joske L. van der Zande, Clarisa I. Sánchez, Bram van Ginneken, Niels van Royen, Ivana Išgum
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE26 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-05322

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Attenuation artifact detection and severity classification in intracoronary OCT using mixed image representations Pierandrea Cancian, Simone Saitta, Xiaojin Gu, Rudolf L.M. van Herten, Thijs J. Luttikholt, Jos Thannhauser, Rick H.J.A. Volleberg, Ruben G.A. van der Waerden, Joske L. van der Zande, Clarisa I. Sánchez, Bram van Ginneken, Niels van Royen, Ivana Išgum Abstract In intracoronary optical coherence tomography (OCT), blood residues and gas bubbles cause attenuation artifacts that can obscure critical vessel structures. The presence and severity of these artifacts may warrant re-acquisition, prolonging procedure time and increasing use of contrast agent. Accurate detection of these artifacts can guide targeted re-acquisition, reducing the amount of repeated scans needed to achieve diagnostically viable images. However, the highly heterogeneous appearance of these artifacts poses a challenge for the automated detection of the affected image regions. To enable automatic detection of the attenuation artifacts caused by blood residues and gas bubbles based on their severity, we propose a convolutional neural network that performs classification of the attenuation lines (A-lines) into three classes: no artifact, mild artifact and severe artifact. Our model extracts and merges features from OCT images in both Cartesian and polar coordinates, where each column of the image represents an A-line. Our method detects the presence of attenuation artifacts in OCT frames reaching F-scores of 0.77 0.77 and 0.94 0.94 for mild and severe artifacts, respectively. The inference time over a full OCT scan is approximately 6 seconds. Our experiments show that analysis of images represented in both Cartesian and polar coordinate systems outperforms the analysis in polar coordinates only, suggesting that these representations contain complementary features. This work lays the foundation for automated artifact assessment and image acquisition guidance in intracoronary OCT imaging. a]Quantitative Healthcare Analysis group, Biomedical Engineering and Physics, Amsterdam UMC, the Netherlands. b]Quantitative Healthcare Analysis group, Informatics Institute, University of Amsterdam, the Netherlands c]Amsterdam Cardiovascular Sciences, Amsterdam UMC, the Netherlands. d]Diagnostic Image Analysis Group, Radboud University Medical Center, Nijmegen, the Netherlands. e]Department of Cardiology, Radboud University Medical Center, Nijmegen, the Netherlands. f]Department of Radiology and Nuclear Medicine, Amsterdam UMC, the Netherlands. keywords Coronary arteries, optical coherence tomography, artifact detection, attenuation artifacts, convolutional neural networks † † authorinfo: Further author information: (Send correspondence to P.C.) P.C.: E-mail: [email protected] 1 INTRODUCTION Intracoronary optical coherence tomography (OCT) is an invasive imaging modality that yields consecutive high-resolution cross-sectional images of a coronary artery segment. OCT can offer accurate information on the vessel microstructure, such as plaque presence and characteristics, as well as details regarding the state of stented lesions [ 1 ] . This imaging technique has been proven to provide valuable complementary information to X-ray angiography in guiding percutaneous revascularization [ 2 , 3 ] . During intracoronary OCT acquisition, the OCT probe emits near-infrared light in a helical pattern, acquiring multiple attenuation lines (A-lines) and forming a 3D volume, which is referred to as a pullback . An OCT pullback consists of a few hundred cross-sectional images of the coronary artery in Cartesian coordinates, referred to as frames . Each frame typically has an in-plane resolution of 10-15 µm, and the length of the pullback can reach 150 mm. During OCT imaging, blood must be completely flushed from within the lumen. Incomplete flushing can leave blood residues in the lumen and cause the formation of gas bubbles within the catheter. Blood residues and gas bubbles cause attenuation artifacts, casting shadows that prevent the light from reaching the arterial wall (Figure 1 ). The presence of these artifacts may mask critical features, leading to incorrect assessment of an intracoronary OCT exam and resulting in misdiagnosis or suboptimal decision making. Automated detection and severity assessment of these artifacts could provide important feedback to the operator; the detection of severe attenuation artifacts can suggest re-acquisition of the pullback, whereas detection of mild artifacts can provide useful information during image interpretation and help identify areas where minor corrections can enhance the overall image quality. Despite the relevance of automated image quality assessment, to the best of our knowledge no method on attenuation artifacts detection in intracoronary OCT has been presented. Rather, earlier studies focused on the correction of a specific class of artifacts, most commonly the shadow cast by the OCT guidewire. For example, Gharaibeh et al. [ 4 ] approached guidewire artifact and stent struts’ shadow inpainting with conditional generative adversarial networks. Thereafter, Luo et al. [ 5 ] devised a sophisticated deep learning solution for guidewire inpainting that leveraged both texture-focused and structure-focused frames. Tao et al. [ 6 ] developed a physics-inspired model to correct contrast agent attenuation and OCT defocus. Jessney et al. [ 7 ] showed how the correction of common mild artifacts, such as gas bubbles, blood residues, and seam artifacts, through a Fourier transform-based approach can improve identification of higher-risk features and plaque classification. Instead of focusing on artifact correction, Cheimariotis et al. [ 8 ] developed a multi-step image processing pipeline for lumen border detection that is resistant to blood residues. These studies underscore the importance of dealing with artifacts to improve OCT image analysis. The objective of the present study is to develop an automatic method for the detection of attenuation artifacts caused by blood residues or gas bubbles according to their severity. For this purpose, we propose a convolutional neural network (CNN) that performs A-line classification into severity classes, exploiting the inherent radial structure of the attenuation artifacts. Figure 1: Examples of two optical coherence tomography images in the Cartesian domain and their polar counterpart, with annotated artifacts. The first and third image from the left show frames in Cartesian coordinates and the second and fourth in polar coordinates. Mild artifacts are indicated in yellow and severe in blue. Arcs in the Cartesian domain correspond to straight segments in polar coordinates, where the columns of the image are equivalent to the original A-lines. In polar coordinates the artifacts and their shadows are vertically aligned. 2 DATA We included 80 pullbacks from 75 patients from PECTUS-obs [ 9 , 10 ] , a prospective observational study that includes pullbacks with non-flow-limiting, nonculprit lesions of patients with myocardial infarction. All patients provided informed consent. The reference standard included three classes indicating artifact presence and severity: none , mild and severe . The reference classes did not distinguish whether the attenuation was due to a gas bubble or a blood artifact. Mild artifacts were defined as those casting faint shadows that still allowed discerning the underlying structures, while severe artifacts made interpretation impossible. To define the reference standard, A-lines were annotated using the brush tool within ITK-SNAP [ 11 ] to paint the corresponding label over the artifact-affected arcs. This operation was performed on images visualized in Cartesian coordinates. Figure 1 shows an example of the annotated arcs. The annotation of each frame was then processed to derive a vector \mathbf{y}\in\{0,1,2\}^{\vartheta} , where \vartheta is the number of A-lines per frame. The pullbacks and frames selected for annotation were chosen such that the annotated dataset would be heterogeneous in terms of artifact appearance. Possible variations in appearance included high versus low mixing of blood residues within the lumen and the size of the gas bubbles. The dataset also included frames featuring red thrombi, pathological structures that

Read the complete text