Julius Reinhard , 1,2*,† Felix Wiesner , 1,2,† Themistoklis Sidiropoulos , 3 Martin Hennecke , 3 Sophia Kaleta , 1,2 Julian Späthe , 1 Johann Jakob Abel, 1 Martin Wünsche , 1,2,4 Gabriele Schmidl, 5 Jonathan Plentz , 5 Uwe Hübner, 5 Katharina Freiberg , 6 Jonathan Apell, 6,7 Stephanie Lippmann , 8 M · 2025
Read Soft X-ray imaging with coherence tomography in the water window spectral range using high-harmonic generation by Julius Reinhard , 1,2*,† Felix Wiesner , 1,2,† Themistoklis Sidiropoulos , 3 Martin Hennecke , 3 Sophia Kaleta , 1,2 Julian Späthe , 1 Johann Jakob Abel, 1 Martin Wünsche , 1,2,4 Gabriele Schmidl, 5 Jonathan Plentz , 5 Uwe Hübner, 5 Katharina Freiberg , 6 Jonathan Apell, 6,7 Stephanie Lippmann , 8 M (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-04276.txt.
Introduction
Julius Reinhard, Felix Wiesner, and co-workers showed soft X-ray depth imaging driven by a tabletop light source in a 2025 paper. High-harmonic making produces coherent extreme ultraviolet light in the lab, but its speed falls toward higher photon energies. Blocking use in the soft X-ray water window. The band where carbon absorbs strongly and water stays transparent, ideal for imaging living and layered samples. The team pushed a high-flux harmonic source across that whole band anyway.
With it they performed soft X-ray coherence tomography, adapted from the optical technique, reading depth shapes inside a layered heterostructure without destroying it. The broadband, noise-resistant method reached an axial resolution of about twelve nanometers. Lab-scale sources that image in the water window could bring such analysis to plain facilities.
Catalog record
| CREATOR | Julius Reinhard , 1,2*,† Felix Wiesner , 1,2,† Themistoklis Sidiropoulos , 3 Martin Hennecke , 3 Sophia Kaleta , 1,2 Julian Späthe , 1 Johann Jakob Abel, 1 Martin Wünsche , 1,2,4 Gabriele Schmidl, 5 Jonathan Plentz , 5 Uwe Hübner, 5 Katharina Freiberg , 6 Jonathan Apell, 6,7 Stephanie Lippmann , 8 M |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 31 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-04276
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Soft X-ray imaging with coherence tomography in the water window spectral range using high-harmonic generation Julius Reinhard , 1,2*,† Felix Wiesner , 1,2,† Themistoklis Sidiropoulos , 3 Martin Hennecke , 3 Sophia Kaleta , 1,2 Julian Späthe , 1 Johann Jakob Abel, 1 Martin Wünsche , 1,2,4 Gabriele Schmidl, 5 Jonathan Plentz , 5 Uwe Hübner, 5 Katharina Freiberg , 6 Jonathan Apell, 6,7 Stephanie Lippmann , 8 Matthias Schnürer, 3 Stefan Eisebitt , 3,9 Gerhard G. Paulus , 1,2 Silvio Fuchs 1,2,10* 1 Institute of Optics and Quantum Electronics, Friedrich Schiller University Jena, Max-Wien-Platz 1, Jena, 07743, Germany 2 Helmholtz Institute Jena, GSI Helmholtzzentrum für Schwerionenforschung, Fraunhoferstr. 8, Jena, 07743, Germany 3 Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, Max-Born-Straße 2A, Berlin, 12489, Germany 4 Indigo Optical Systems GmbH, Moritz-von-Rohr-Str. 1a, Jena, 07745, Germany 5 Leibniz Institute of Photonic Technology (Leibniz-IPHT), Albert-Einstein-Str. 9, Jena, 07745, Germany 6 Otto Schott Institute of Materials Research Friedrich Schiller University Jena, Löbdergraben 32, Jena, 07743, Germany 7 Institute of Materials Science and Engineering, Chemnitz University of Technology, Erfenschlager Str. 73, Chemnitz, 09125 Germany 8 Institute of Applied Physics, Friedrich Schiller University Jena, Albert-Einstein-Str. 15, Jena, 07745 Germany 9 Institute for Optics and Atomic Physics, Technische Universität Berlin, Straße des 17. Juni 135, Berlin, 10623 Germany 10 Laserinstitut Hochschule Mittweida, University of Applied Science Mittweida, Technikumplatz 17, Mittweida, 09648 Germany † These authors contributed equally to this work. * Correspondence: [email protected], [email protected] Abstract Abstract High-harmonic generation (HHG) is used as a source for various imaging applications in the extreme ultraviolet spectral range. It offers spatially coherent radiation and unique elemental contrast with the potential for attosecond time resolution. The unfavorable efficiency scaling to higher photon energies prevented the imaging application in the soft X-ray range so far. In this work we demonstrate the feasibility of using harmonics for imaging in the water window spectral region (284 eV to 532 eV). We achieve nondestructive depth profile imaging in a heterostructure by utilizing a broadband and noise-resistant technique called soft X-ray Coherence Tomography (SXCT) at a high-flux lab-scale HHG source. SXCT is derived from Optical Coherence Tomography, a Fourier based technique, that can use the full bandwidth of the source to reach an axial resolution of 12 nm in this demonstration. The employed source covers the entire water window, with a photon flux exceeding 10 {}^{\text{6}} photons/eV/s at a photon energy of 500 eV. We show local cross sections of a sample consisting of Aluminium oxide and Platinum layers of varying thickness on a Zinc oxide substrate. We validate the findings with scanning and transmission electron microscopy after preparation with focused ion beam milling. Introduction High-harmonic generation (HHG) has proven to be an exceptional source for nanoscale extreme ultraviolet (EUV) imaging due to its laser-like properties and small laboratory footprint 1 , 2 , 3 . In particular, coherent imaging methods such as ptychography benefit from the high spatial coherence and have demonstrated their remarkable potential in recent years achieving wavelength-scale resolution 4 , 5 , 6 , 7 . In addition, the strong elemental contrast opens up a wide field of applications from semiconductor studies 8 and mask inspection 9 to biological samples 10 , 11 , 12 . Even buried structures can be examined using EUV light from HHG sources 13 , 14 , 15 . However, the penetration depth is severely limited by the strong absorption of most materials. Further decreasing the wavelength to the soft X-ray (SXR) range would not only decisively increase the penetration depth for a great variety of materials, but would also enhance the resolution as demonstrated at synchrotron sources 16 . Especially the so-called water window (WW), defined by the absorption edges of carbon ( \approx 284 eV or 4.4 nm) and oxygen ( \approx 532 eV or 2.3 nm), is of particular interest due to its high contrast and penetration depth in many materials, e.g. biological materials 17 , 18 , 19 . HHG-driven imaging in the soft X-ray or more specifically the water window spectral range has has not yet been demonstrated, primarily for two reasons. On the one hand, the available photon flux of HHG sources in the SXR range is severely limited. Extending the HHG spectral range into the water window typically requires ultrafast driver lasers with wavelengths above 1 µm. Unfortunately, this reduces the conversion efficiency of the process, which scales with \sim\lambda^{-5...-6} 20 . Therefore, SXR-HHG have only been used for various spectroscopic applications that exploit the femto- or even attosecond pulse lengths 21 , 22 , 23 . On the other hand, the intrinsically broadband harmonic spectrum is not efficiently used by the established EUV imaging methods like Ptychography, which typically require monochromatic light and consequently only use a small fraction of the available photon flux. Thus, intrinsically broadband imaging techniques are better suited for flux-limited HHG sources in the water window spectral range. In this work, we demonstrate the feasibility of HHG-driven imaging in the water window by combining a cutting-edge WW-HHG source with a broadband and noise resistant technique called soft X-ray coherence tomography (SXCT). The HHG source is driven by a few-cycle 2.1 µm laser 24 and generates a broad spectrum covering the entire water window with more than 5 \times 10 5 ph/eV/s at the oxygen K-edge (2.33 nm) 25 . To our knowledge, no other HHG source was able to apply these photon numbers in experiments yet. Moreover, SXCT exploits the full bandwidth of the source to reconstruct depth structures with nanometer-scale axial resolution. This imaging technique is derived from spectral-domain optical coherence tomography (OCT, 26 ) and functions as a reflective method, enabling the investigation of structures on bulk materials such as microchips. It even enables the study of weakly reflective samples due to its Fourier-based nature, which provides exceptional noise resistance. Furthermore, three-dimensional information can be obtained by laterally scanning the sample. We investigated a sample composed of an aluminum oxide layer and a platinum layer deposited on a zinc oxide substrate using SXCT. A cross-sectional image was obtained scanning across the edge of the buried platinum layer, achieving a depth resolution of 12 nm. To validate the axial structure and inhomogeneities detected with SXCT, we conducted scanning and transmission electron microscopy (SEM and TEM) following focused ion beam (FIB) milling. HHG source and SXR Coherence Tomography The demonstration of HHG-driven water window imaging was enabled by a high-flux HHG source covering the entire water window spectral range 24 , 25 . The source is based on an optical parametric chirped-pulse amplification (OPCPA) system, driven by a 500 W thin-disk laser to reach a central wavelength of 2.1 µm and an average power of 28 W at pulse duration of 27 fs. The beam is focused with a 750 mm lens into a helium gas cell, where the HHG process occurs. The resulting spectrum covers a broad spectral range from 200 eV to 600 eV, with a photon flux of 5 \times 10 5 ph/eV/s at the oxygen K-edge at \approx 532 eV 25 . The HHG spectrum which was used for the SXCT measurements is shown in Fig. .a. Figure 1: Illumination spectrum, measured sample reflectivity, and reconstructed depth structure arranged on top of