Quality Concerns Caused by Quality Control - deformation of silicon strip detector modules in thermal cycling tests

Alex Zeng Wang · 2025

Read Quality Concerns Caused by Quality Control - deformation of silicon strip detector modules in thermal cycling tests by Alex Zeng Wang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-03133.txt.

Introduction

A large ATLAS team reports in 2025 that heat cycling tests warped silicon strip detector modules built for a collider upgrade. About 19,000 modules will form the outer strip tracker, each cycled ten times between cold and warm points to prove it can work at deep cold. Shape checks were run before and after the cycles.

Modules changed shape across the cycles, a sign of excess stress in the build. The paper traces the cause and links the warp to that stress. The team then changed the cycling plan to lower the harm while keeping the quality checks in place.

Catalog record

CREATORAlex Zeng Wang
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE23 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-03133

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Quality Concerns Caused by Quality Control - deformation of silicon strip detector modules in thermal cycling tests Alex Zeng Wang Abstract The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 ℃ (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector’s operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 ℃ and +40 ℃ are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure. 1 Introduction The HL-LHC upgrade introduces increased luminosity, resulting in increased radiation damage to the detector, such that the current ATLAS Inner Detector cannot be operated in the post-upgrade conditions. Thus, the Inner Detector will be replaced with the all-silicon ATLAS Inner Tracker (ITk), containing an inner pixel detector region surrounded by an outer strip detector region. The strip detector is composed of an array of modules in a central barrel region, along with two endcap regions on either side. Silicon strip detector modules, shown in Figure 1 , are constructed by gluing hybrid and powerboard flexes to the surface of silicon sensors. Strip modules are assembled in a series of assembly steps that incorporate a quality control (QC) procedure, after which the completed modules are loaded onto support structures. Among other tests, QC includes visual inspections, electrical tests, shape measurements and thermal cycling. Figure 1 : Exploded view of barrel module components from [ 1 ] . Thermal cycling is the final step in QC, in which modules must operate when cycling between temperature extremes of -35 ℃ and +40 ℃ [ 2 ] . The cycling temperatures were chosen to cover the full potential operational range in the detector. During the strip module pre-production, it was found that modules that had passed QC had gone on to fail IV tests while mounted on support structures and cooled down. An investigation into module stress followed, with the aim of developing a better understanding of the source of the on-structure failures. The investigation into sources of stress led to the addition of module shape measurements after thermal cycling, in addition to the standard shape measurements done prior to cycling. Module shapes were found to be significantly different before and after thermal cycling. This study presents the change in module shape associated with the thermal cycling protocol and the source of module stresses prior to loading onto support structures. 2 Modules and QC Modules are constructed from components in a series of manual precision assembly steps, with module component materials and thicknesses indicated in Table 1 . Modules in the barrel region, shown in Figure 1 , are square long-strip (LS) or short-strip (SS). Modules in the endcap are approximately trapezoidal, with curved edges. Hybrids are the flexible circuit boards that hold the readout chips (ASICs) responsible for registering hit signals, as well as housing thermistors for temperature monitoring. The powerboard provides the DC-DC power for the module. To assemble a module, the ASICs are glued and wirebonded to the hybrids, then the hybrids and powerboard are glued to the sensor, following which the hybrids and sensor are wirebonded together. Component Materia l Thickness Sensor Silicon 300-320 µm Hybrids (Endcap) Copper, Polyimide 240-285 µm Hybrids (Barrel) Copper, Polyimide 378-462 µm Powerboard (Endcap) Copper, Polyimide 218-322 µm Powerboard (Barrel) Copper, Polyimide 385 µm Table 1 : Module component dimensions for endcap and barrel variants [ 3 ] . In order to ensure compatibility with the detector requirements, QC processes are performed after each module assembly step [ 1 ] , as shown in Table 2 . Assembly Steps HV tab attached to sensor Glued Wirebonded QC Steps • IV test • Visual inspection • Visual inspection • Weighing • Metrology • Module shape • IV test • Module shape • IV test • Visual inspection • Full electrical test • Thermal cycling Table 2 : The sequence of assembly steps and the respective QC steps. Modules that pass all QC requirements are glued and wirebonded to staves or petals, shown in Figure 2 . The analyses presented in this study rely on measurements of the module shape (see section 2.1) and module leakage current tests (see section 2.2) in QC. Figure 2 : Schematic of a petal loaded with completed endcap modules. Hybrids and powerboards are attached to sensors using a two-component epoxy glue. The glue selected for module assembly, among other criteria, requires a short curing time, with minimal volume change to allow for precise positioning of components, as well as neutral interaction with the components to ensure good electrical performance. It must be stable under irradiation, and the glass transition temperature ( T_{g} ) must be significantly higher than the expected operating range of -35 ℃ to +20 ℃, as ASICs are known to reach up to +30 ℃ higher than the module ceiling temperature of +20 ℃. 2.1 Module Shape Measurement Module shapes are measured with the module placed on a flat surface to obtain its natural shape. Out-of-plane height measurements are taken on a grid of points across the sensor surface that are at most 1 cm apart, see Figure 3 . This is the general procedure for the module shape tests. (a) (b) Figure 3 : Measurement grid on a barrel module. The blue points represent measurements taken in the module shape test, with the full module shape interpolated in orange. The powerboard and hybrid flexes are not measured, as they are not considered in the module shape. The module shape test in QC requires the module shape coefficient to measure between -50 µm and +150 µm [ 4 ] to ensure that modules will be compatible with the procedure for loading onto support structures. The shape measurements form a surface map of the measured module. To calculate the shape coefficient, only points on the sensor are considered (i.e. points measured on flexes or readout chips are not considered). Using all the sensor surface points, a tilt corrected surface map is obtained by using a plane fit, an example of which is shown in Figure 4 . The maximum height difference between points on the sensor is used as the module shape coefficient. The module shown in

Read the complete text