Impact of trace amounts of water on the stability of Micro-Pattern Gaseous Detectors Journal: NIM A

H. Fribert, L. Fabbietti, P. Gasik, B. Ulukutlu · 2025

Read Impact of trace amounts of water on the stability of Micro-Pattern Gaseous Detectors Journal: NIM A by H. Fribert, L. Fabbietti, P. Gasik, B. Ulukutlu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-03012.txt.

Introduction

Fribert and co-authors test how traces of water vapor affect gas detectors used in particle physics, in a 2025 paper. The detectors, of three micro-pattern types, run on an argon and carbon dioxide mix. Even tiny amounts of water, up to 5,000 parts per million, might change how stably they run.

Across the humidity range, none of the main performance measures got notably worse. At the highest gains and electric fields, more humidity actually improved discharge stability, cutting the rate of stray sparks. Those sparks are blamed on electrode flaws and on charge building up in insulating layers. At lower gains, humidity made no clear difference. The authors conclude that adding a little water to the gas may be a cheap way to keep such detectors running steadily.

Catalog record

CREATORH. Fribert, L. Fabbietti, P. Gasik, B. Ulukutlu
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-03012

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Impact of trace amounts of water on the stability of Micro-Pattern Gaseous Detectors Journal: NIM A H. Fribert, L. Fabbietti, P. Gasik, B. Ulukutlu Abstract In this study, we investigate the influence of humidity on the performance of various non-resistive Micro Pattern Gaseous Detectors, such as GEM, Thick-GEM, and Micromegas, operated with Ar-CO 2 (90-10) gas mixture. The water content is introduced in a range of 0 – 5000 ppm V 05000\text{\,}\mathrm{p}\mathrm{p}\mathrm{m}_{\mathrm{V}} . It is observed that the presence of increased humidity does not significantly degrade any of the studied performance criteria. On the contrary, our measurements suggest an improvement in discharge stability with increasing humidity levels at the highest gains and fields. No significant difference is observed at the lower gains, indicating that humidity helps to reduce the rate of spurious discharges related to electrode defects or charging-up of the insulating layers. We conclude that adding a small amount of water to the gas mixture may be beneficial for the stable operation of an MPGD. 1 Introduction Figure 1 : The experimental setup of the detector chamber and the gas system used to humidify the gas mixture. Despite several decades of experience in the production and successful operation of Micro Pattern Gaseous Detectors (MPGDs, see recent review in [ 1 ] ), the effect of water contamination in the gas composition on their performance is still a subject of debate. Previous studies regarding the addition of water vapour to the gas are inconclusive, and no consensus has been reached, especially concerning discharge stability and the influence on streamer development [ 2 , 3 , 4 ] . Adding small amounts of water vapour to the gas may benefit detector operation by preventing the glue used in detector components from drying out and helping to mitigate ageing effects [ 5 ] . However, an adverse effect of small amounts of humidity in the gas mixture on the detector performance has to be ruled out before its utilisation in experiments. To resolve this question, we study various MPGDs, including Gas Electron Multiplier (GEM) [ 6 ] , Thick Gas Electron Multiplier (THGEM 1 1 1 The results have been partially published in [ 7 ] ) [ 8 , 9 ] , and the Micro-mesh gaseous structure (Micromegas, MMG) [ 10 ] . We investigate different performance criteria of the detectors, including gain and energy resolution, and put a particular focus on discharge stability. We examine the impact of water vapour in the gas mixture on detector performance by building a dedicated setup to introduce and vary the humidity between measurements. Our measurements are performed at the absolute humidity levels of 05000\text{\,}\mathrm{p}\mathrm{p}\mathrm{m}_{\mathrm{V}} (parts per million, proportion by volume), which correspond to a relative humidity (RH) value of up to \sim 20% at normal temperature and pressure conditions. It should be noted that several groups reported various instabilities in MPGD detectors appearing at much larger relative humidity values while operating/testing a detector structure in an air atmosphere in the laboratory. In [ 11 ] , instabilities such as increased leakage current and spark rate were observed in GEMs operated in ambient, cleanroom conditions (RH \approx 50%). Similar observations have also been made with other types of MPGDs (see, for example, [ 12 ] for resistive Micromegas or recent results with µRGroove presented in [ 13 ] ). For this reason, the humidity limits for the quality control procedures of MPGDs are usually put below the RH value of 50% or even below 10%, as required in the recently concluded large-scale productions for the LHC detector upgrades [ 14 , 15 , 16 ] . This is well in line with the range considered in this work. In the presented studies, we focus on the fundamental stability limits of MPGD-based detectors in a gas mixture with trace amounts of water, and the regions of large RH ( >50\% ) are not considered here. 2 Experimental setup and methods 2.1 Gas system The gas mixture used in the presented studies is Ar-CO 2 (90-10). A dedicated setup is built to study the effect of humidity on MPGDs, in which a constant amount of water vapour is reliably introduced to the gas. Figure 1 demonstrates the humidification process. The original gas mixture flows through a piping system, splitting into two separate lines. One line incorporates a bubbler filled with distilled water, allowing the gas to absorb humidity without introducing additional contaminants like oxygen. Different humidity levels can be achieved by adjusting the flow through the bubbler using a mass flow meter, as shown in Fig. 2 . Simultaneously, the second line directs dry gas around the humidifying line until they merge. The resulting gas mixture is flushed through the detector chamber while a rotameter in the dry gas line regulates and monitors the flow. A Rapidox 3100 Multigas Analyser from Cambridge Sensotec is placed after the detector vessel to record the oxygen and humidity content of the mixture. The oxygen content is kept at a minimum ( <25 ppm V ) throughout all measurements. The ambient conditions are tracked with thermometers and a pressure sensor. Figure 2 : Gas contaminants recorded during a test measurement. The initial spike in the oxygen content corresponds to the activation of the humidifier at time zero. It is demonstrated that humidity can be controlled reliably by changing the flow rate through the bubbler. Table 1 : A list of MPGD structures used in this study. The naming convention for Micromegas follows the one established in [ 17 ] . The main geometrical parameters are specified: d_{\mathrm{ins}} - Apical ® /FR4 thickness (for GEM/THGEM, respectively), d_{\mathrm{Cu}} - copper cladding thickness, \diameter - hole diameter (inner/outer), the hole pitch, z_{\mathrm{MMG}} - amplification gap given by the thickness of the Pyralux ® PC1025 pillars, d_{\mathrm{wire}} - wire thickness, a_{\mathrm{wire}} - distance between the wire edges (inner dimensions of a mesh cell), density in lines per inch, optical transparency. All meshes are woven. The THGEM has no rims around the holes. MPGD (TH)GEM Micromegas d_{\mathrm{ins}} d_{\mathrm{Cu}} \diameter Pitch z_{\mathrm{MMG}} d_{\mathrm{wire}} a_{\mathrm{wire}} Density Transparency Producer [µm] [µm] [µm] [µm] [µm] [µm] [µm] [LPI] [%] GEM (S) 50 5 50/70 140 – – – – 24 CERN GEM (LP) 50 5 50/70 280 – – – – 6 CERN THGEM 400 35 400 800 – – – – 24 Eltos S.p.A. MMG1 – – – – 128 13 22 730 40 CERN MMG3 – – – – 128 18 45 400 51 CERN 2.2 MPGDs The detector setup follows the same scheme for all measurements. It consists of an MPGD mounted between a drift cathode and a readout plane. Table 1 includes a list of all MPGD structures used in this study, together with the main geometrical parameters. GEM and Micromegas structures are 10\times 10 cm 2 large, whereas the area of the THGEM is 11.2\times 11.2 cm 2 . All structures are non-resistive. The drift cathode and the readout anode are both made of 1.5\text{\,}\mathrm{mm} thick PCB, coated on one side with copper. If not stated otherwise, the distance between the source and the MPGD structure is 32\text{\,}\mathrm{mm} , and in the case of the (TH)GEM, the induction gap length is 2\text{\,}\mathrm{mm} throughout all

Read the complete text