Microcell CPT atomic clock using laser current-actuated power modulation with 10 -12 range stability at 1 day
Carlos Manuel Rivera-Aguilar 1, Andrei Mursa 1, Clément Carlé 1, Jean-Michel Friedt 1, Emmanuel Klinger 1, Moustafa Abdel Hafiz 1, Nicolas Passilly 1, Rodolphe Boudot 1 · 2025
Read Microcell CPT atomic clock using laser current-actuated power modulation with 10 -12 range stability at 1 day by Carlos Manuel Rivera-Aguilar 1, Andrei Mursa 1, Clément Carlé 1, Jean-Michel Friedt 1, Emmanuel Klinger 1, Moustafa Abdel Hafiz 1, Nicolas Passilly 1, Rodolphe Boudot 1 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-01681.txt.
Introduction
Carlos Rivera-Aguilar and co-authors present an atomic clock stable to the tenth-of-a-trillion range over a day, in a 2025 paper. The clock uses coherent population trapping in a microfabricated vapour cell. Its pulsed sequence runs by modulating the laser current, so no optical shutter is needed, which suits fully integrated clocks. One digital board controls the sequence.
A key step was tracking the signal window in real time. The team measured how clock frequency responds to laser power, microwave power, laser frequency, and window timing, finding weaker sensitivities than with the standard Ramsey version. The frequency scatter starts near one part in a billion at one second and averages down into the low parts-per-trillion range after a day. The authors say the results clear a path to Ramsey-type chip clocks with better timekeeping.
Catalog record
| CREATOR | Carlos Manuel Rivera-Aguilar 1, Andrei Mursa 1, Clément Carlé 1, Jean-Michel Friedt 1, Emmanuel Klinger 1, Moustafa Abdel Hafiz 1, Nicolas Passilly 1, Rodolphe Boudot 1 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 29 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2503-01681
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Microcell CPT atomic clock using laser current-actuated power modulation with 10 -12 range stability at 1 day Carlos Manuel Rivera-Aguilar 1, Andrei Mursa 1, Clément Carlé 1, Jean-Michel Friedt 1, Emmanuel Klinger 1, Moustafa Abdel Hafiz 1, Nicolas Passilly 1, Rodolphe Boudot 1 Abstract We present a coherent-population trapping (CPT) microcell atomic clock using symmetric auto-balanced Ramsey (SABR) spectroscopy. The pulsed SABR sequence is applied through direct current-based power modulation of the vertical-cavity surface-emitting laser, eliminating the need for an external optical shutter and enabling compatibility with fully-integrated clocks. The sequence is controlled by a single FPGA-based digital electronics board. A key aspect of proper clock operation was the implementation of a real-time tracking of the atomic signal detection window. The clock frequency dependence on laser power, microwave power, laser frequency, and timing of the detection window has been measured, obtaining sensitivity coefficients lower than those obtained with Ramsey-CPT spectroscopy. The Allan deviation of the SABR-CPT clock, based on a microfabricated cell with low-permeation glass windows, is 1.1 × \times 10 -9 at 1 s and averages down to the low 10 -12 range at 1 day integration time. These results pave the way towards the development of Ramsey-CPT chip-scale atomic clocks with enhanced timekeeping performances. I Introduction Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have met a remarkable success in navigation, communication, defense and synchronization systems by offering a fractional frequency stability at 1 day in the 10 -11 range in a low size, weight and power (SWaP) budget Kitching 2018 . These clocks rely on the interaction of a hot alkali vapor, confined in a microfabricated vapor cell in the presence of a pressure of buffer gas Dicke 1953 , with an optically-carried microwave signal obtained by direct current modulation of a vertical-cavity surface emitting laser (VCSEL). Under null Raman detuning condition, atoms are trapped in a quantum dark state Alzetta et al. 1976 for which the atomic vapor transparency is increased, leading to the detection of an atomic resonance, used to stabilize the frequency of the local oscillator (LO) that drives the VCSEL. The fractional frequency stability of CSACs is usually degraded for integration times higher than 100 s by light-shifts. Several approaches have been proposed to mitigate light-shifts in CPT-based CSACs. A widely used technique involves tuning the microwave power set point to cancel at the first order the clock frequency dependence to laser power variations Zhu and Cutler 2000 ; Shah et al. 2006 ; Zhang et al. 2016 . Nevertheless, this microwave power setpoint is specific to the physics-package, may not exist in cells filled with high buffer gas pressures Vaskovskaya et al. 2019 , and only protects the clock frequency from laser power variations. Other techniques, such as the implementation of advanced algorithms for compensation of the laser current-temperature couple Yanagimachi et al. 2020 , the tuning of the cell temperature Miletic et al. 2012 , or the use of interrogation sequences based on power-modulation Yudin et al. 2020 ; Abdel Hafiz et al. 2020 ; Basalaev et al. 2020 , have been proposed. Ramsey spectroscopy is efficient for light-shift reduction. Ramsey-CPT spectroscopy Thomas et al. 1982 ; Zanon et al. 2005 , in which atoms interact with a sequence of optical CPT pulses separated by a free-evolution dark time of length T , was performed first in microfabricated cells in Refs Boudot et al. 2018 ; Carlé et al. 2021 . The symmetric auto-balanced Ramsey (SABR) sequence Abdel Hafiz et al. 2018 was later demonstrated to reduce further the clock frequency dependence to laser power, laser frequency and microwave power Abdel Hafiz et al. 2022 . This approach, combined with the use of a microcell made with low permeation glass substrates Carlé et al. 2023 , has enabled the demonstration of a microcell CPT clock with fractional frequency stability in the low 10 -12 range at 1 day Carlé et al. 2023 . Nevertheless, in the studies mentioned above, the pulsed optical sequence was produced using an external optical shutter, typically an acousto-optic modulator (AOM), which is incompatible with a fully-integrated CSAC. To address this challenge, operation of a Ramsey-CPT microcell atomic clock, with driving-current based power modulation of the VCSEL through a two-step pulse sequence Ide et al. 2015 ; Fukuoka et al. 2023 ; Fukuoka and Goka 2024 , was recently reported Rivera-Aguilar et al. 2024 . This paper showed a tenfold reduction of the clock frequency sensitivity to laser power compared to the continuous-wave (CW) case. The clock stability, extracted from a 10-hour measurement, reached 1.3 \times 10 -10 \tau^{-1/2} , with limitations after 2000 s likely due to light-shifts and buffer gas permeation through the cell windows. Figure 1: (a) Experimental setup. A hot Cs vapor, confined in a microfabricated vapor cell filled with a buffer gas pressure, interacts with a dual-frequency optical field obtained by direct modulation at 4.596 GHz of the VCSEL current. Atoms are trapped in the CPT dark state using both first-order optical sidebands. The signal at the cell output is used in three servo loops, for laser frequency and LO frequency, as well as light-shift compensation. CL: collimation lens LO: local oscillator. The inset shows a photograph of the Cs-Ne vapor microcell. The experiment is controlled by a single FPGA RedPitaya digital electronics board, shown in the lower-left corner. (b) SABR sequence used for interrogation of the atoms. Instead of interacting continuously with light as in traditional CPT clocks, atoms experience here a sequence of two-step pulses, of total length T_{b} , separated by free-evolution times ( T_{S} or T_{L} ) in the dark, during which the light is actually turned off by tuning the laser current below the laser threshold current. The pulsed light sequence is then obtained by current-actuated power modulation of the laser. In this work, we demonstrate a Cs microcell CPT clock based on the SABR interrogation, which offers advantages over the Ramsey-CPT one. The SABR sequence, generated using an FPGA-based electronics board, is produced by directly modulating the VCSEL dc current, eliminating the need for an AOM and then being compliant with a fully-integrated CSAC. In this work, atoms in the microcell experience 170- \mu s-long optical CPT pulses, separated by a short dark time T_{s} of 150 \mu s or a long dark time T_{L} of 250 \mu s. The atomic signal is typically measured 18 \mu s after the beginning of each pulse in a 1 \mu s-long averaging window. An important step for proper operation of the clock was the implementation of a detection window tracking system, aimed to compensate for the timing jitter of the detection window caused by current step-induced thermal transients of the laser frequency along the sequence. The clock frequency sensitivity coefficients to laser power, microwave power, and laser frequency are all reduced in comparison with those obtained with Ramsey-CPT spectroscopy. The frequency stability of the microcell SABR-CPT clock, extracted from a 5-day measurement, is 1.1 \times 10 -9 at 1 s and reaches the level of 2.4 \times 10 -12 at 2 \times 10 5 s. Figure 2: FPGA implementation of the SABR-CPT clock operation. II Experimental setup The experimental setup, shown in Fig. 1 (a), is