Exploring Three-Atom-Thick Gold Structures as a Benchmark for Atomic-Scale Calibration of Break-Junction Systems

J.P. Cuenca, T. de Ara, A. Martinez-Garcia, F. Guzman, C. Sabater · 2025

Read Exploring Three-Atom-Thick Gold Structures as a Benchmark for Atomic-Scale Calibration of Break-Junction Systems by J.P. Cuenca, T. de Ara, A. Martinez-Garcia, F. Guzman, C. Sabater (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2503-00161.txt.

Introduction

Cuenca and co-authors stretch gold until it is three atoms thick in a 2025 physics paper. Break junction rigs pull a metal contact apart and read current through the thinning neck. Earlier work proved chains one and two atoms thick. Combining transport readings with simulations, the team find strong evidence for three atom thick structures under tension.

Tests ran cold and at room conditions. The structures' known length then becomes a ruler: a fast, robust way to turn the rig's piezo motion into true distance. Calibration is the quiet bottleneck of atomic scale electronics. A built in gold standard, grown by the experiment itself, could steady measurements across labs.

Catalog record

CREATORJ.P. Cuenca, T. de Ara, A. Martinez-Garcia, F. Guzman, C. Sabater
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2503-00161

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Exploring Three-Atom-Thick Gold Structures as a Benchmark for Atomic-Scale Calibration of Break-Junction Systems Preprint: APS/123-QED J.P. Cuenca, T. de Ara, A. Martinez-Garcia, F. Guzman, C. Sabater Abstract We present an in-depth study of electronic transport in atomic-sized gold contacts using Break-Junction (BJ) techniques under cryogenic and ambient conditions. Our experimental results, supported by classical molecular dynamics (CMD) simulations and ab initio calculations, provide compelling evidence for the formation of three-atom-thick structures in gold nanocontacts under tensile stress. These findings extend previous studies that confirmed the existence of one- and two-atom-thick chains. Beyond identifying these novel atomic configurations, we introduce a fast and robust calibration method for Break-Junction systems, leveraging the characteristic length of these structures to convert piezo-distance into absolute distance in angstroms. Our approach presents a novel and robust method for calibrating atomic distances in atomic conductor systems at both cryogenic and room temperatures. The results also enable the assessment of electrode sharpness, even under ambient conditions. I Introduction In the field of molecular and atomic electronics Cuevas and Scheer 2017 , one of the challenges is understanding the structure of electrodes at the nanoscale Agraït et al. 1993 ; Krans et al. 1993 ; Agraït et al. 2003 ; Evers et al. 2020 . Typically, the most common techniques used to determine the electronic transport are the Scanning Tunneling Microscope in its break junction configuration (STM-BJ) Pascual et al. 1993 and the Mechanically Controllable Break Junction (MCBJ) Krans et al. 1993 ; Krans and van Ruitenbeek 1994 ; Krans et al. 1995 . Both methods are commonly used at low-temperature (4.2 K) and room conditions. However, measuring electronic transport through these techniques is insufficient to fully reveal the atomic structure. Usually, these experiments are supported by CMD simulations Landman et al. 1990 and ab initio electronic transport calculations Ventra 2008 ; Haug and Jauho 1996 ; Cuevas and Scheer 2017 ; Brandbyge et al. 2002 ; Rocha et al. 2006 ; Pauly et al. 2008 ; Jacob and Palacios 2011 ; Ferrer et al. 2014 . Despite significant progress in understanding the geometry of atomic-sized gold contacts and the number of atoms coordinated between them Yanson et al. 1998 ; Smit et al. 2001 ; Untiedt et al. 2007 ; Sabater et al. 2012 ; Sabater et al. 2013 ; Dednam et al. 2015 ; Fernández et al. 2016 ; Sabater et al. 2018 ; Sabater et al. 2020 ; Dednam et al. 2022 , only atomic structures with one or two atoms of thickness have been identified so far, particularly at low temperatures. While all the studies have shed light on the structure and behavior of one- and two-atom-thick chains Yanson et al. 1998 ; Sabater et al. 2020 , contacts thicker than two atoms have not been extensively studied at low temperatures, let alone under ambient conditions. Therefore, our goal is to investigate the existence of three-atom-thick structures and explore their use for calibrating the break-junction (BJ) system across different environments. In this manuscript, we have combined STM-BJ at cryogenic temperature and MCBJ at room conditions experiments, CMD simulations, and electronic transport calculations. Thanks to this combination, we have identified three-atom-thick structures. Not only has there been progress in techniques to understand the atomic-sized contact geometries, but significant advancements have also been made in calibrating STM-BJ and MCBJ at low temperatures Untiedt et al. 2002 . However, when it comes to developing new methods for calibrating a MCBJ at ambient conditions, progress has been limited. In our case, we have used the structures composed by three, two and one- atom-thick to calibrate or convert the applied voltage to the piezo system in relative displacement between electrodes. Once our systems are calibrated, we can represent conductance versus calibrated displacement, allowing us to study the slope of these curves historically named traces of conductance. In summary, after unmasking the existence of three atom structures, our approach provides a rapid and robust method for calibrating distances, offering new insights into the geometry of atomic contacts at cryogenic temperature and room conditions. Another important aspect of our study is that, once the calibration is completed and after analyzing the slopes of conductance versus relative displacement curves, we can determine how much atomically sharpened the electrodes are during the dynamic process of rupture. II Methods and Materials II.1 Electronic transport in BJ techniques The most commonly used experimental techniques for measuring electronic transport in atomic-sized contacts Agraït et al. 2003 ; Cuevas and Scheer 2017 ; Evers et al. 2020 are the Scanning Tunneling Microscope in its break junction configuration (STM-BJ) Pascual et al. 1993 ; Agraït et al. 1993 and the Mechanically Controllable Break Junction (MCBJ) Krans et al. 1993 ; Krans et al. 1995 . Figure 1: Panel (a) shows an illustration of STM and panel (b) shows the MCBJ experimental setups. Panel (c) illustrates an atomic-sized contact connected in series with a battery and an ammeter. In this paper, we analyzed atomic-sized gold contacts using break-junction techniques. Specifically, we performed experiments at low temperatures (4.2 K) using the STM-BJ method, while for experiments under ambient conditions, we employed the MCBJ technique. For the STM, the gold electrodes consisted of two wires with a diameter of 0.25 mm (Goodfellow), positioned facing each other by their circular surfaces and intersecting perpendicularly (see Figure 1 (a)). In contrast, for the MBCJ, a single notched gold wire was used, grooved, and deposited onto a bendable substrate, as Figure 1 (b) shows. Regardless of the method used to create the atomic-sized contact, we measured the conductance using two probes with DC current. Figure 1 (c) illustrates a schematic of the basic circuit connections for measuring the current in an atomic-sized contact, where the bias voltage ( V_{bias} ) is applied to the atomic contact, which is connected in series with the ammeter. The conductance G can be expressed in terms of the current I and the applied voltage V_{\text{bias}} as G=\frac{1}{R}=\frac{I}{V_{\text{bias}}} . This conductance is often described using the Landauer formalism, which expresses it in terms of the quantum of conductance and the addition of transmission probability T_{i} of the i -th conducting channel, which maximum value per channel can be one. In this framework, the total conductance is given by G=G_{0}\sum_{i}T_{i} , where G_{0} is the quantum of conductance defined as G_{0}=\frac{2e^{2}}{h}\approx\frac{1}{12906}\ \Omega^{-1} , with e being the elementary charge, h Planck’s constant, and the factor of 2 accounting for spin degeneracy (since each quantum channel can carry two spin states). This formulation highlights that conductance at the quantum scale is quantized in units of G_{0} , modulated by the transmission probabilities of the available channels. In our experiments, the bias voltage applied in both configurations (STM-BJ and MCBJ) was 100 mV, and the current was measured by a Femto I/V converter (model DLPCA-200) using an amplification factor of 10^{5} V/A. In our case, the current-to-voltage amplifier is connected to Data Acquisition System (DAQ), which allow us to record the conductance versus relative displacement. Given that we are working with experiments involving junction rupture, we will represent conductance as a function of the relative distance between electrodes, which can be expressed in Ångströms if the system is calibrated, or in units of

Read the complete text