Read Linnik point spread functions, time-reversed logarithmic diffusion equations, and blind deconvolution of electron microscope imagery by Alfred S. Carasso and Andras E. Vladar and Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899. ([email protected]) (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-19420.txt.
Introduction
Alfred Carasso and Andras Vladar (2025) adapt a sharpening method from telescope images to electron microscope pictures. The method undoes blur without knowing the exact blur shape, a task called blind deconvolution. It works when the image's frequency pattern falls in a smooth, convex way, though it cannot fix blur from bad focus. The authors assume the blur follows a Linnik probability curve. They fit its settings to the prepared microscope image by least squares.
Sharpening then walks backward through a logarithmic diffusion equation in frequency space. The best result usually appears partway back, not at full reversal. Tests on scanning electron and helium ion microscope images showed real gains in crispness. The process needs a user who knows microscope images and can search the settings by hand. The authors present it as a practical tool for nanoscale imaging labs.
Catalog record
| CREATOR | Alfred S. Carasso and Andras E. Vladar and Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899. ([email protected]) |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 13 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-19420
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Linnik point spread functions, time-reversed logarithmic diffusion equations, and blind deconvolution of electron microscope imagery Alfred S. Carasso and Andras E. Vladar and Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899. ([email protected]) Abstract A non-iterative direct blind deconvolution procedure, previously used successfully to sharpen Hubble Space Telescope imagery, is now found useful in sharpening nanoscale scanning electron microscope (SEM) and helium ion microscope (HIM) images. The method is restricted to images g ( x , y ) g(x,y) , whose Fourier transforms g ^ ( ξ , η ) \hat{g}(\xi,\eta) are such that l o g | g ^ ( ξ , 0 ) | log~|\hat{g}(\xi,0)| is globally monotone decreasing and convex. The method is not applicable to defocus blurs. A point spread function in the form of a Linnik probability density function is postulated, with parameters obtained by least squares fitting the Fourier transform of the preconditioned microscopy image. Deconvolution is implemented in slow motion by marching backward in time, in Fourier space, from t = 1 t=1 to t = 0 t=0 , in an associated logarithmic diffusion equation. Best results are usually found in a partial deconvolution at time t ¯ \bar{t} , with 0 < t ¯ < 1 0<\bar{t}<1 , rather than in total deconvolution at t = 0 t=0 . The method requires familarity with microscopy images, as well as interactive search for optimal parameters. keywords SEM images; HIM images; sharpening; denoising; deblurring; blind deconvolution; Linnik point spread functions; time-reversed logarithmic diffusion equations. 1 Introduction There are numerous processes for the extraction of meaningful information contained in various images. For proper identification, interpretion, and analysis, a human observer must first be able to perceive and recognize all of the information contained in a given image. Often, valuable pertinent information lies in faint details. A combination of local contrast enhancement and sharpening of fine image details, is especially helpful for scanning electron microscope (SEM) and helium ion microscope (HIM) images. Modern SEMs and HIMs can resolve sub-nanometer details [ 8 ] , but their images often suffer from low contrast and appreciable noise. As a result, fine details can easily be overlooked. Denoising, contrast stretching, and sharpening, can significantly improve the results of quantitative analyses of these images. This paper describes a new non-iterative , direct blind deconvolution procedure for sharpening images obtained from scanning electron microscopes, and Helium ion microscopes. As was the case in [ 3 , 4 , 5 , 6 ] , the present method is only applicable to a restricted class of blurred images g(x,y) , with Fourier transforms \hat{g}(\xi,\eta) such that log~|\hat{g}(\xi,0)| is globally monotone decreasing and convex. The method does not apply to defocus and motion blurs. We view the given image g(x,y) as the convolution of the desired sharp image f(x,y) with an unknown point spread function h(x,y) , together with an unknown amount of noise n(x,y) , g(x,y)=\int_{R^{2}}h(x-u,y-v)f(u,v)dudv+n(x,y)=h\otimes f+n(x,y). (1) After an appropriate preconditioning of the microscopy image g(x,y) , the method is based on postulating a point spread function in the form of a Linnik probability density function h(x,y) , and then identifying the parameters \gamma,~\lambda>0, in the corresponding Linnik optical transfer function \hat{h}(\xi,\eta)=\{1+4\pi^{2}\gamma(\xi^{2}+\eta^{2})\}^{-\lambda}, (2) by least squares fitting the Fourier transform of the preconditioned g(x,y) . Here, for any function p(x,y) in L^{1}(R^{2}) , we define its Fourier transform \hat{p}(\xi,\eta) by \hat{p}(\xi,\eta)=\int_{R^{2}}p(x,y)e^{-2\pi i(\xi x+\eta y)}dxdy. (3) With the Linnik optical transfer function \hat{h}(\xi,\eta) in Eq. ( 2 ), it is useful to define \hat{h}(\xi,\eta,t) as follows for 0\leq t\leq 1 , \hat{h}(\xi,\eta,t)=\{1+4\pi^{2}\gamma(\xi^{2}+\eta^{2})\}^{-\lambda t},\qquad 0\leq t\leq 1. (4) Fig. 1: As shown in [ 6 ] , the use of Linnik probability densities, rather than Lévy stable densities, produces better results in deblurring astronomical imagery. Above Whirlpool Galaxy image was obtained at Kitt Peak National Observarory. Successful Linnik deblurring of several Hubble Space Telescope color images may also be found in [ 6 ] . Horizontal Field Width (HFW) in above images is approximately 53,000 light years. Previous non-iterative direct blind deconvolution methods, based on candidate point spread functions in the form of heavy-tailed Lévy stable probability densities, were successfully used in several applications [ 1 , 2 , 3 , 4 , 5 ] . In that approach, fast Fourier transform (FFT) algorithms are used to implement the deconvolution as a backward in time stepwise marching procedure, from t=1 to t=0 , in a diffusion equation involving fractional powers of the negative Laplacan. Stopping the process prior to reaching t=0 , produces a partial deconvolution which is often beneficial. In [ 6 ] , the use of Linnik probability densities, rather than Lévy stable densities, was found to produce significantly better results in deblurring Hubble Space Telescope and other astronomical imagery. This is illustrated in Figure 1.1, in the case of a Kitt Peak National Observatory image of the Whirlpool Galaxy (M51), obtained by Rector and Ramirez. In the Linnik blind deconvolution procedure discussed in [ 6 ] , deconvolution unfolds as a backward in time marching procedure, from t=1 to t=0 , in a diffusion equation involving the logarithm of the identity plus the negative Laplacian, w_{t}=-\lambda\{log(I+\gamma(-\Delta)\}w . Using the Lipschitz exponent theory developed in [ 7 ] , it can be shown quantitatively that the rightmost image in Figure 1.1 is significantly sharper than the other two images. The behavior of Linnik versus Lévy optical transfer functions at high and low frequencies, is discussed in [ 6 , Sections 4-6] , and that behavior is used to explain these improved sharpness results. 2 Preconditioning microscopy images An important first step prior to Linnik blind deconvolution of microscopy images, consists of applying adaptive histogram equalization (ADHE) to the image. However, while this brings out useful information, it also produces significant noise. Smoothing that noisy image by convolution with a low exponent Lévy probability density function is helpful. This is illustrated in Figure 2.1. In the smoothed ADHE image g(x,y) , least squares fitting log|\hat{g}(\xi,0)| with the expression -\lambda(log(1+4\pi^{2}\gamma\xi^{2})-b , where b>0 is an appropriately chosen constant, leads to parameter values for \lambda and \gamma in \hat{h}(\xi,\eta) defined in Eq. ( 2 ). This is shown in Figure 2.2. Fig. 2: Adaptive Histogram Equalization (ADHE), reveals valuable information while generating significant noise that must be smoothed out. This is reflected in the respective Fourier spectra. Above images are 1\mu m HFW secondary electron images. Fig. 3: In the smoothed ADHE image g(x,y) , least squares fitting log|\hat{g}(\xi,0)| with the expression -\lambda(log(1+4\pi^{2}\gamma\xi^{2})-1.5 , leads to parameter values \lambda=0.969,~\gamma=1.64 , for \hat{h}(\xi,\eta) in Eq. ( 2 ) Fig. 4: Partial deconvolution sequence with s=0.001,~K=300 . Best image is found at some ~\bar{t}~ lying between t=0.75 and t=0.8 . At smaller t values, \parallel w(.,t_{n})\parallel_{tv} increases rapidly as serious noise develops. Above images are 1\mu m HFW secondary electron images. 3 Deconvolution by marching diffusion equations backward in time As was the case in [ 4 , Section 3] , the Linnik blind deconvolution problem is solved by marching the logarithmic diffusion equation, w_{t}=-\lambda\{log(I+\gamma(-\Delta)\}w , backward in time from t=1 to t=0 , using the preconditioned microscopy image g(x,y) as data at t=1 . The slow