Smart Sampling Strategies for Wireless Industrial Data Acquisition Minimizing Aliasing While Preserving Trends for Machine Learning Models
Soto Marcos · 2025
Read Smart Sampling Strategies for Wireless Industrial Data Acquisition Minimizing Aliasing While Preserving Trends for Machine Learning Models by Soto Marcos (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-17454.txt.
Introduction
Marcos Soto, writing alone, presents smart sampling methods for wireless industrial sensors in this 2025 paper. Accurate data drives process control, and wireless tools now stream readings from deep wells in real time. Very fast sampling, though, drains batteries and fills storage and bandwidth.
Soto explores sampling plans that cut distortion and steady errors while keeping the trends that learning models need. The study achieved an 80 percent cut in sampling frequency with no loss of measurement quality. The result points to large savings in storage, transmission, and power for industrial monitoring, without giving up the accuracy that control decisions rely on.
Catalog record
| CREATOR | Soto Marcos |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 26 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-17454
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Smart Sampling Strategies for Wireless Industrial Data Acquisition Minimizing Aliasing While Preserving Trends for Machine Learning Models Soto Marcos Abstract In industrial environments, data acquisition accuracy is crucial for process control and optimization. Wireless telemetry has proven to be a valuable tool for improving efficiency in well-testing operations, enabling bidirectional communication and real-time control of downhole tools Acar et al. 2014a . There is a growing adoption of wireless systems due to their advantages. However, the high sampling frequencies required present significant challenges in telemetry, including data storage, data transmission, computational resource consumption, and battery wear of wireless devices Julius & Shastry, n.d.a n.d. . This study explores how applying mathematical techniques for optimizing a real data acquisition system can detect aliasing effects, and systematic errors, and improve sampling rates without compromising the accuracy of physical measurements. An 80% reduction in the sampling frequency was achieved without compromising measurement quality. These findings provide a basis for optimizing the implementation of wireless data acquisition systems in industrial environments. 1 Introduction As a fundamental task in the oil exploration industry, well testing is a process in which the production of a well is measured over a specified period, either at the wellhead using portable equipment or at a production facility. Its primary purpose is to evaluate key reservoir parameters such as permeability, hydraulic connectivity, and average reservoir pressure. In exploratory wells, it is used to collect fluid samples, measure initial pressure, and estimate the reservoir’s minimum volume. In production wells, it allows verifying permeability, identifying fluid behaviors, and evaluating heterogeneities. Regarding the produced phases or fluids from this operation, liquids such as water and oil are stored in atmospheric tanks, while gas is usually flared or delivered to a sales point. This process is crucial to ensure proper reservoir characterization, optimize production, and minimize errors in operational and strategic decision-making. Accurate measurements ensure that reservoir models reflect real conditions more precisely, maximizing project profitability and minimizing risks Petroleum 2019a . This study focuses on analyzing the relationship between sampling frequency F_{s} and the quality of a measured signal, evaluated through the relative error between the original signal and the reconstructed signal. In data acquisition systems, choosing an appropriate sampling frequency is crucial to ensure measurement accuracy while minimizing storage and transmission costs. However, lower sampling frequencies can introduce aliasing errors, affecting the quality of signal reconstruction. Aliasing is a phenomenon that occurs when the sampling frequency is insufficient to accurately capture the variability of a signal, causing important patterns to be distorted or even lost. In industrial systems, this can be critical as it may prevent early detection of anomalies in the data, affecting the ability of machine learning (ML) models to prevent failures or detect key trends. Therefore, optimizing the sampling rate is not just about reducing data acquisition but about ensuring that downsampled signals retain their essential characteristics for predictive analytics. In this context, the specific case of gas measurement is investigated, excluding liquid measurement as it can be contrasted with accumulated tank volume. In contrast, gas must be measured in real time since, once vented or burned, it cannot be subsequently contrasted. Therefore, the goal is to investigate whether it is possible to reduce the sampling frequency using compensation techniques to maintain the error within acceptable limits. Some previous studies have explored techniques for energy-efficient data acquisition, Law et al. 2009a adapting industrial sampling frequency, but not in their specific application to reduce aliasing in signals allowing their behavior patterns to be maintained in gas measurements in well-testing environments. This would allow optimizing the resources associated with data storage and transmission without compromising the quality of the measurements. 2 Objective This study aims to determine the minimum sampling frequency that optimizes data storage and transmission in wireless acquisition systems while ensuring that the signal quality is maintained. Specifically, the goal is to avoid aliasing errors that could affect the ability of ML models to identify trends and detect anomalies in industrial environments. By striking a balance between efficient data acquisition and signal preservation, we ensure that the reduced sampling frequency does not compromise the effectiveness of predictive models used in industrial monitoring. To achieve the study’s objective, the aim is to determine the optimal sampling frequency F_{s} that minimizes the costs associated with the data acquisition system while maintaining a relative error E_{\text{relative}} below a target value E_{\text{objective}} . To this end, the following objectives are proposed: • Evaluate the impact of F_{s} on the relative error of the uncompensated signal. • Implement compensation techniques to reduce relative error at lower sampling frequencies. • Define a cost function that combines the impact of relative error with storage and transmission costs. • Solve an optimization problem to identify the minimum sampling frequency that meets the established quality criteria. It is crucial to ensure measurement quality to maintain a functional dynamic system with sufficient representation of measured magnitudes. For example, if anomaly detection models rely on measured trends, discretization errors that significantly alter the signal representation can negatively impact such dependent models. 3 Methodology 3.1 Mathematical Framework Relative error: It is defined as the main metric to evaluate the quality of the signal reconstruction: E_{\text{relative}}=\frac{\|S_{\text{original}}-S_{\text{rebuilt}}\|}{\|S_{\text{original}}\|} Where S_{\text{original}} is the original signal and S_{\text{rebuilt}} is the reconstructed signal after subsampling and applying compensation techniques. 3.2 Cost function In wireless systems, the transmission cost is directly related to the energy consumption of the sensor, while the storage cost depends on the amount of data generated, proportional to the sampling frequency F_{s} . Therefore, the cost function is posed as: C(f_{s})=k_{a}f_{s}+k_{t}E\text{trans}(f_{s})+\lambda E_{\text{relative}} Where: • k_{a} : Constant representing the cost proportional to data storage. • k_{t} : Constant that represents the cost associated with energy consumption per transmission. • E_{\text{trans}}(f_{s}) : Energy consumption associated with data transmission at a sampling frequency f_{s} . • \lambda : Weight that reflects the relative importance of the error in the total cost function. For wireless sensors, E_{\text{trans}}(f_{s}) can be approximated as a proportional to the number of transmissions: E_{\text{trans}}(f_{s})=f_{s}\times E_{\text{unit}} Where n_{\text{trans}} is the number of transmissions in period T at a sampling frequency f_{s} , and E_{\text{unit}} is the energy consumption per transmission. Quality constraint: To ensure that the signal quality is acceptable, the following is set: E_{\text{relative}}\leq E_{\text{target}} 3.3 Relationship between frequency and relative error According to the Nyquist criterion, the sampling frequency should be in the range: f_{s}\in\left[f_{\text{min}},2f_{\text{max}}\right] where f_{\text{min}} is the minimum acceptable sampling frequency according to the target error E_{\text{target}} . The aliasing error is evaluated as the accumulated difference between the original and reconstructed signals in the frequency domain: E_{\text{aliasing}}=\int_{f_{s}}^{2f_{\text{max}}}\left|S_{\text{original}}(f)-S_{\text{rebuilt}}(f)\right|\,df This allows us to evaluate the magnitude of the error when reducing f_{s} , considering its impact on the quality of the reconstructed signal. Aljameel et al. 2022a 3.4 Experimental Setup The experimental process consists of the following steps: 3.5 Data Collection Data collection: Real-time data is collected from a wireless sensor network in an industrial environment, focusing on gas measurements in well-testing operations. Several datasets collected from different time periods and different oil wells were used, obtained from well testing services at oil and gas companies. The data includes gas, oil and water flow measurements. The data was originally sampled