Characterization of proton-induced damage in thick, p-channel skipper-CCDs
Brenda A. Cervantes-Vergara, Santiago E. Perez, Claudio Chavez, Fernando Chierchie, Brandon Roach, Juan Estrada, Alex Drlica-Wagner · 2025
Read Characterization of proton-induced damage in thick, p-channel skipper-CCDs by Brenda A. Cervantes-Vergara, Santiago E. Perez, Claudio Chavez, Fernando Chierchie, Brandon Roach, Juan Estrada, Alex Drlica-Wagner (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-16350.txt.
Introduction
Brenda Cervantes-Vergara and co-authors test radiation damage in advanced light sensors in a 2025 paper. The sensors, called skipper-CCDs, can count single electrons and serve in astronomy and physics. The team exposed two thick sensors to high energy protons and then measured how their performance changed.
The sensors kept their single electron sensitivity after a heavy proton dose. Using a pocket pumping technique, the team counted and identified the defects the protons created. They found an overall trap density and named three main trap species, with measured energies and cross sections. One species mattered most for charge quality at working temperatures. Tests of the output transistors showed no shifts in threshold voltage. The authors highlight the sensors tolerance for harsh settings.
Catalog record
| CREATOR | Brenda A. Cervantes-Vergara, Santiago E. Perez, Claudio Chavez, Fernando Chierchie, Brandon Roach, Juan Estrada, Alex Drlica-Wagner |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 30 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-16350
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Characterization of proton-induced damage in thick, p-channel skipper-CCDs Brenda A. Cervantes-Vergara, Santiago E. Perez, Claudio Chavez, Fernando Chierchie, Brandon Roach, Juan Estrada, Alex Drlica-Wagner Abstract In this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 2.3\times 10^{7} MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated. 1 Introduction Charge-Coupled Devices (CCDs), pixelated ionization sensors, are a well-established technology widely used in various scientific applications due to their attractive features, including high quantum efficiency, low dark counts, and low readout noise. Skipper-CCDs combine these features with the added advantage of single-electron/single-photon sensitivity, enabled by their ability to perform multiple non-destructive measurements of the charge in each pixel. This technology has demonstrated excellent performance in applications requiring sensitivity to faint signals, such as direct dark matter detection [ 1 , 2 , 3 ] and astronomical spectroscopy [ 4 ] . To extend its use to scientific applications where detectors are expected to operate in high-radiation environments, such as space missions or accelerator-based experiments, it is essential to demonstrate and quantify its radiation tolerance. Studies on total dose radiation damage in silicon detectors [ 5 , 6 ] , and particularly in CCDs [ 7 , 8 , 9 , 10 ] , are extensive, and generally classify it into two types: ionization damage and displacement damage. On one hand, ionization damage primarily degrades the insulator layer by creating interface defects and trapped charge within the layer. Interface defects can lead to higher surface dark counts, and trapped charge can lead to voltage shifts causing charge-transfer inefficiency (CTI) between pixels or changes in the operating point of the CCD transistors. On the other hand, displacement damage produces vacancy-interstitial pairs which later form more stable defects within the bulk, such as divacancies and vacancy-impurity complexes, that create intermediate energy levels acting as charge traps. This damage can induce CTI and higher dark counts from hot pixels, the latter primarily promoted by defects with an energy level close to midgap. The susceptibility of CCDs to ionization damage varies significantly depending on their design and the irradiation conditions. In most cases, the effects of this damage can be mitigated, making displacement damage the primary limiting factor for CCD applications in high-radiation environments [ 9 ] . Regarding displacement damage, studies indicate that p-channel CCDs are radiation harder than n-channel CCDs due to the characteristics of the induced defects [ 11 , 12 , 13 , 14 ] . The dominant radiation-generated trap in n-channel CCDs is the phosphorous-vacancy (PV) electron trap [ 15 ] , while in p-channel CCDs, it is the divacancy (V 2 ) hole trap [ 11 ] . P-channel CCDs are considered radiation harder because: 1) the formation of V 2 traps in p-channel CCDs is predicted to be less favorable compared to the formation of PV traps in n-channel CCDs [ 14 ] , and 2) the PV trap energy ( \sim 0.42-0.46 eV below the conduction band) is closer to midgap than the V 2 trap energy ( \sim 0.21-0.23 eV above the valence band), leading to higher dark counts in n-channel CCDs. 2 Proton irradiation of skipper-CCDs The sensors tested in this work are thick, p-channel skipper-CCDs, fabricated from high-resistivity n-type silicon, designed at the Lawrence Berkeley National Laboratory (LBNL) in collaboration with the Fermi National Accelerator Laboratory (FNAL) during the R&D phases of the SENSEI and Oscura [ 16 ] dark matter experiments, and fabricated in two different foundries. Each sensor features an array of three-phase 15 \times 15 \mu m 2 pixels, and four floating-gate readout amplifiers, one in each corner. The sensors were irradiated unbiased and at room temperature at the Northwestern Medicine Proton Center in Warrenville, Illinois, in August 2023, using a 217-MeV proton cyclotron; for details, see Ref. [ 17 ] . To ensure a baseline for comparison, at least a region within the sensor active area and a couple of readout amplifiers of each sensor were kept outside the proton beam line during irradiation as shown in Fig. 1 . Figure 1: Pictures of the irradiated skipper-CCDs (the sensors tested in this work are highlighted in green) and drawings showing the approximate area irradiated by the proton beam (pink) in each sensor (gray). Proton fluences were chosen to reach displacement damage doses (DDD) higher than the estimated for the SNAP satellite orbiting at the second Earth-Sun Lagrange point (L2) for six years, i.e. 6.6\times 10^{6} MeV/g (Si) [ 18 ] . We compute the expected DDD for each fluence assuming a non-ionizing energy loss (NIEL) factor of 1.9\times 10^{-3} MeV cm 2 /g for 217-MeV protons in silicon [ 19 ] . The expected total ionizing dose (TID) for each fluence was computed assuming an electronic stopping power of 3.456 (3.605) MeV cm 2 /g for 217-MeV protons in silicon (silicon dioxide) [ 19 ] . Table 1 summarizes the main characteristics of the sensors tested in this work, the proton fluences they were irradiated with, and their expected damage doses. Sensor ID Pixel array size Thickness Fluence [p/cm 2 ] DDD [ 10^{8} MeV/g] TID [ 10^{11} MeV/g] P1-S3 1022\times 682 675 \mu m 1.2\times 10^{10} 0.23 (Si) 0.41 (Si), 0.43 (SiO 2 ) P2-S3 1278\times 1058 725 \mu m 8.4\times 10^{10} 1.60 (Si) 2.90 (Si), 3.03 (SiO 2 ) Table 1: Geometrical characteristics of the tested sensors, the proton fluences they were irradiated with, and their expected damage doses. 3 Characterization of proton-induced damage The irradiated sensors were packaged and tested at FNAL. For packaging, the sensor and a Kapton flex cable are glued to a silicon substrate, and the sensor is wire-bonded to the cable. The assembly, consisting of the sensor, flex cable, and substrate, is enclosed within a two-piece copper tray, forming a packaged sensor. For testing, each packaged sensor is mechanically attached to the cold tip of a cryocooler located inside a vacuum chamber. The sensor’s flex cable connects to a feedthrough connector on the vacuum side of the chamber, which in turn connects to a Low Threshold Acquisition (LTA) electronics board [ 20 ] on the air side. This board is used for sensor control and