Read BS-Breath: Respiration Sensing with Cell-free Massive MIMO by Haoqiu Xiong 1 , Robbert Beerten 1 , Zhuangzhuang Cui 1 , Yang Miao 2 , Sofie Pollin 1 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-12114.txt.
Introduction
Haoqiu Xiong and co-authors show that a mobile base station can sense breathing in a 2025 paper. Their setup uses a cell-free massive antenna system built for communication, not medicine. A person near a user device sends pilot signals upward, and the station reads the pattern.
A single antenna method first blends many signal channels into one breathing trace. A weighted step then merges traces from many antennas. Using both space and frequency resources beat single antenna or single channel reads. Average match with true breathing reached a strong level in tests. The work hints that future networks could sense health as they carry data.
Catalog record
| CREATOR | Haoqiu Xiong 1 , Robbert Beerten 1 , Zhuangzhuang Cui 1 , Yang Miao 2 , Sofie Pollin 1 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 19 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-12114
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
BS-Breath: Respiration Sensing with Cell-free Massive MIMO Thanks: This work is supported by the Horizon Europe Research and Innovation programme with Grant Agreement No. 101192521 (MultiX), and No. 101096954 (6G-BRICKS). The code and the data for the experiments can be found at: https://gitlab.kuleuven.be/u0149002/bs-breath Haoqiu Xiong 1 , Robbert Beerten 1 , Zhuangzhuang Cui 1 , Yang Miao 2 , Sofie Pollin 1 Abstract This paper demonstrates the feasibility of respiration pattern estimation utilizing a communication-centric cell-free massive MIMO OFDM BS ( BS ). The sensing target is typically positioned near the UE ( UE ), which transmits uplink pilots to the BS . Our results demonstrate the potential of massive MIMO systems for accurate and reliable vital sign estimation. Initially, we adopt a single antenna sensing solution that combines multiple subcarriers and a breathing projection to align the 2D complex breathing pattern to a single displacement dimension. Then, WAC ( WAC ) aggregates the 1D breathing signals from multiple antennas. The results demonstrate that the combination of space-frequency resources—specifically in terms of subcarriers and antennas—yields higher accuracy than using only a single antenna or subcarrier. Our results significantly improved respiration estimation accuracy by using multiple subcarriers and antennas. With WAC , we achieved an average correlation of 0.8 with ground truth data, compared to 0.6 for single antenna or subcarrier methods—a 0.2 correlation increase. Moreover, the system produced perfect breathing rate estimates. These findings suggest that the limited bandwidth (18 MHz in the testbed) can be effectively compensated by utilizing spatial resources, such as distributed antennas. I Introduction In recent years, the increase of wireless devices has not only strained the available spectrum resources but also highlighted the need for innovative technological solutions that can multitask, fulfilling the dual roles of communication and sensing. Integrated Sensing and Communications (ISAC) represents a pivotal advancement in this direction, promising enhanced spectrum efficiency and resource reusability [ 1 ] . This paper delves into a novel ISAC application: utilizing a Base Station (BS) infrastructure for passive respiration monitoring, an essential component of health monitoring systems. By re-purposing existing massive MIMO-OFDM communication systems, we propose a cost-effective deployment strategy that does not demand additional spectrum resources or an infrastructure overhaul. The advent of massive MIMO systems has revolutionized communications by significantly improving signal quality and channel capacity [ 2 , 3 ] . Additionally, in sensing, research [ 4 ] has demonstrated that near-field massive MIMO can compensate for limited bandwidth while achieving high-range resolution at the centimeter level. However, its potential in vital signs sensing remains largely untapped. Previous studies [ 5 , 6 ] have explored beamforming techniques for multiperson vital signs sensing with MIMO radar, yet they did not investigate the spatial diversity of MIMO for enhancing sensing accuracy. Research like DiverSense [ 7 ] extended the Wi-Fi sensing range by leveraging subcarrier and antenna diversity. However, typical Wi-Fi systems have limited antennas (e.g., up to three antennas with an Intel 5300 Wi-Fi chip [ 8 ] ). This motivates our investigation in this paper. Specifically, we investigate how multiple subcarriers and antennas can be combined in the massive MIMO-OFDM system to enhance the accuracy and reliability of respiration estimation, which is crucial in health monitoring applications. Contributions: To the best of our knowledge, we are the first to demonstrate the practical use of a cell-free massive MIMO BS for highly precise vital signs sensing. Specifically, our study evaluates the performance improvements obtained through multiple subcarrier and antenna signal processing techniques such as IDFT ( IDFT ) [ 9 , 10 ] , DiverSense [ 7 ] , and the WAC across multiple antennas. Unlike other approaches, our method does not rely on specific UE or BS orientation relative to the user, thanks to the spatial diversity enabled by cell-free MIMO. II System Model Our analysis considers a cell-free Massive MIMO communication system operating under the TDD ( TDD ) mode, utilizing an OFDM waveform. The BS estimates the CSI ( CSI ) of the UL ( UL ) channel over the full bandwidth of the system. This CSI is estimated from known orthogonal pilot sequences transmitted by the UE s, as shown in Fig. 1 . Fig. 1 : Cell-free uplink respiration sensing. The UL pilots are transmitted at regular intervals i=1\dots I of T_{s} seconds each with I total frames per measurement. Each frame consists of subcarriers k=1\dots K , each equally spaced at \Delta f Hz within the total bandwidth B . Therefore the CSI estimated by the M antennas of the BS can be represented by the complex tensor: H_{\text{CSI}}\in\mathbb{C}^{M\times K\times I}. (1) We consider there are L distinct paths between UE and BS , each indexed by l\in 1\dots L . Each path is characterized by amplitudes \alpha_{l} and propagation delays \tau_{l} . The measured CFR ( CFR ) at the m -th antenna of BS , on the k -th subcarrier and i -th frame, is represented as h_{mk}[i]=\sum_{l=1}^{L}\alpha_{mkl}[i]e^{-j2\pi(f_{c}+k\Delta f)\tau_{ml}[i]}, (2) where \alpha_{mkl}[i] and \tau_{ml}[i] may vary over time, particularly in the presence of moving targets such as a chest. In addition, the multipath also differs across various received antennas due to the diverse propagation geometries between the transmitter and receiver. The path delay \tau_{ml}[i] can be expanded as \tau_{ml}[i]=\frac{\dot{d}_{ml}+b[i]}{c}(m-1)\sin(\theta_{ml}[i])\cos(\frac{\beta_{ml}[i]}{2}), (3) where \dot{d}_{ml} , b[i] , \theta_{ml}[i] , and \beta_{ml}[i] refer to the initial path length, the chest displacement during the i -th frame, the AoA ( AoA ), and the bistatic angle [ 11 ] , respectively. \cos(\frac{\beta_{ml}[i]}{2}) is the bistatic projection factor from target movement to changes in multipath length [ 12 ] . III Signal Processing The underlying principle of respiration estimation is straightforward: displacement of the chest during breathing alters the lengths of multipath components reflecting off the chest. This change, in turn, affects both the phase and amplitude of the received multipath components, as shown in Eqs. ( 2 ) and ( 3 ). Because breathing displacement b_{i} leads to different phase shifts in the different subcarriers and antennas, the question becomes how to combine these many subcarriers and antennas optimally. This section compares different signal processing algorithms designed explicitly for respiration sensing. III-A Evaluation Methods To evaluate the performance of the proposed methods, we introduce our evaluation method for the estimated breathing signals here. We cross-correlate the estimated power normalized with ground-truth breathing signals obtained using a camera-based Mocap ( Mocap ). The correlation value ranges between 0 and 1, where 1 means that the estimation is identical to the ground truth. This metric is more informative than the average bpm ( bpm ), especially with varying breathing rates. An example is shown in Fig. 2 , where the first antenna gives a correlation value of 0.826 while obtaining the same bpm as the ground truth. III-B Multiple Subcarrier Signal Processing The first question is how to combine multiple subcarriers K . Signals reflecting off the chest and surroundings create multiple paths that sum at the receiver, sometimes coherently adding or canceling each other out, affecting the estimated breathing patterns. Two main methods are applied to solve the multipath fading: 1) IDFT [ 9 ] and 2) DiverSense [ 7 ] , and then determine a single estimated range