Calibration features of a polarimetric backscattering setup with a beamsplitter

V. Stefanov, B.P. Singh and A. Stefanov · 2025

Read Calibration features of a polarimetric backscattering setup with a beamsplitter by V. Stefanov, B.P. Singh and A. Stefanov (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-10763.txt.

Introduction

Light bouncing off a surface carries a twist, its polarization, that can reveal what the surface is made of. A three author team studies in 2025 how to calibrate a setup that reads that twist in backscattered light when a beamsplitter sits in the path. The splitter's own effect on the light can quietly skew every reading.

Using a measure of information, they justify a layout of reference parts that lets the splitter be treated as part of the setup rather than a part to remove and test alone. Computer trials showed the plan raises precision. They also give a test that estimates the error made when the splitter's effect is ignored. The authors aim the work at cleaner optical measurements.

Catalog record

CREATORV. Stefanov, B.P. Singh and A. Stefanov
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2502-10763

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Calibration features of a polarimetric backscattering setup with a beamsplitter V. Stefanov, B.P. Singh and A. Stefanov Abstract We address the problem of calibrating a polarimetric backscattering setup that includes a beamsplitter, taking its optical properties into account. Using Fisher information, we justify a specific calibration configuration involving reference optical elements for the maximum likelihood method and demonstrate its effectiveness through Monte Carlo simulations. This approach leads to higher precision, as the described set of measurements allows the beamsplitter to be treated as an integral part of the setup, without requiring separate processing or reconfiguration of the setup for the beamsplitter calibration. Furthermore, we emphasize the significance of considering the beamsplitter’s optical properties by proposing a test to estimate the error that arises from neglecting these properties during the calibration procedure. I Introduction Polarimetry is a powerful experimental tool for characterizing the optical properties of objects of interest. It has numerous applications in fields such as biomedical research [ 1 , 2 ] , astronomy [ 3 , 4 ] , and geology [ 5 ] , among others [ 6 ] . The distinctly different polarization features of an object’s components provide excellent contrast and high sensitivity. Today, polarimetry-based devices are among the most promising tools for recognizing various types of cancer in vivo or during surgical procedures [ 7 , 8 , 9 ] . The full polarimetric properties of samples can be probed either in transmission or reflection. The typical reflection configuration is only sensitive to the surface of the sample [ 10 , 11 , 12 ] . In this work, we focus on the so-called backscattering configuration [ 13 , 14 , 15 ] , which allows for the study of the internal scattering properties of a sample, rather than just its surface. This makes it particularly useful for applications beyond histological analysis [ 14 ] . A set of points with equal polarimetric properties can delineate boundaries between regions with different internal structures, such as the boundary between anisotropic brain tissue and tumors [ 16 , 14 ] . When combined with time-resolved detection, this method potentially enables the study of tissue samples layer by layer to the full penetration depth [ 17 ] . The backscattering setup uses focused illumination, implying a short working distance. As a result, the illumination light is typically separated from the collected backscattered light using a beamsplitter (BS). The technical essence of polarimetry lies in defining the so-called Mueller matrix for each point of the studied object. The 4\times 4 Mueller matrix provides complete information about the polarization properties, enabling the prediction of all possible polarizations of scattered light at a given point. The definition of a Mueller matrix requires conducting at least 16 measurements for each pair of the four possible input and output polarizations (which are generated by a polarization state generator (PSG) and a polarization state analyzer (PSA), respectively). Our knowledge of the values of PSG and PSA is one of the key factors determining the accuracy of the setup. Several calibration methods are available to measure these values, including eigenvalue calibration methods (ECM) [ 18 , 19 , 20 ] , the maximum likelihood calibration method (MLCM) [ 21 ] , and others [ 22 , 23 ] . However, these methods are generally not suitable for a backscattering polarimetric setup involving a BS, due to the need to account for its specific optical properties. Some variants of the ECM method [ 24 , 25 ] can be applied under certain assumptions about the Mueller matrix of the BS. Nevertheless, the BS is typically calibrated separately from the rest of the setup [ 26 ] , which still introduces errors in the final configuration of the system. In this paper, we present a configuration of reference elements that allows the calibration of the setup directly via MLCM, without the need for additional manipulation of the BS. (a) (b) Figure 1: Two different principal schemes of a polarimetric back-scattering setup (a) reflective and (b) scanning. The paper is organized as follows: first, we provide a brief review of common calibration methods. Next, we describe a suitable calibration scheme for a BS setup and explain the features of using various optical elements. We then propose a test to estimate the errors of different calibration schemes, and, finally, we demonstrate the superiority of the suggested scheme through experimental validation, followed by a discussion. II Common calibration methods We can collect the Stokes vectors generated by the PSG and PSA in matrices, denoted W and A , respectively. This allows us to express the measured intensity values in a matrix I and match the expression I=AMW in the configuration without a BS (Type I in Fig. 1 (a)) and I=ATMBW in the configuration with a BS (Type II in Fig. 1 (b)), where M , B , and T are the Mueller matrices of the sample, the reflected side of the BS, and the transmitted side of the BS, respectively. Calibration involves retrieving the pair of matrices A and W for Type I, or AT and BW for Type II, from a set of measurements. For this purpose, reference optical elements with known or easily reconstructed Mueller matrices are used, such as linear polarizers ( P ), wave plates, mirrors, or other reflected samples ( R ). Below, we briefly explain the essence of the eigenvalue calibration method (ECM) [ 18 ] and the maximum likelihood calibration method (MLCM) [ 21 ] . II.1 Eigenvalues Calibration Method According to the ECM, the four measured intensity matrices - two with reflected samples ( AR_{1}W , AR_{2}W ), one with a linear polarizer placed after the PSG ( AR_{1}PW ), and one with a linear polarizer placed before the PSA ( APR_{1}W ) - are sufficient for calibration. The method is based on the fact that the eigenvalues of W^{-1}R_{1}W are the same as those of R_{1} . For this reason, calculating the eigenvalues of the expression (AR_{1}W)^{-1}(AR_{1}PW) allows us to restore the Mueller matrix of the linear polarizer P independently of its orientation angle \theta , while the expression (AR_{1}W)^{-1}(AR_{2}W) allows us to restore the intermediate matrix R_{1}^{-1}R_{2} . Due to the presence of noise, we must apply an additional transformation, so we define the matrices H_{1}(\theta) (as a function of \theta ) and H_{2} : \displaystyle H_{1}(\theta) \displaystyle= \displaystyle E\otimes P(\theta)-\left[(AR_{1}W)^{-1}(AR_{1}PW)\right]^{T}\otimes E, (1) \displaystyle H_{2} \displaystyle= \displaystyle E\otimes R_{1}^{-1}R_{2}-\left[(AR_{1}W)^{-1}(AR_{2}W)\right]^{T}\otimes E, (2) where \otimes means tensor product, E is the identity matrix, P(\theta)=J(\theta)PJ(-\theta) is a Mueller matrix with the polarizer matrix P=\tau_{p}\mathfrak{G}(1,0,0) and with a rotation matrix J(\theta) : \mathfrak{G}(x,y,z)=\frac{1}{2}\left[\begin{array}[]{cccc}1&x&0&0\\ x&1&0&0\\ 0&0&y&z\\ 0&0&-z&y\end{array}\right],\quad J(\theta)=\left[\begin{array}[]{cccc}1&0&0&0\\ 0&\cos 2\theta&-\sin 2\theta&0\\ 0&\sin 2\theta&\cos 2\theta&0\\ 0&0&0&1\end{array}\right]. (3) The Mueller matrices of reflected samples are parametrized as follows: R_{m}=R(\tau_{m},\psi_{m},\Delta_{m})\equiv 2\tau_{m}\mathfrak{G}(-\cos 2\psi_{m},\sin 2\psi_{m}\cos\Delta_{m},\sin 2\psi_{m}\sin\Delta_{m}), (4) for m=1,2 , where \tau is a transmissivity, \psi and \Delta are ellipsometric angles. The linear mapping K(\theta) is given by: K(\theta)=H_{1}(\theta)^{T}H_{1}(\theta)+H_{2}^{T}H_{2}, (5) and it allows for the definition of the orientation of the linear polarizer \theta by minimizing the ratio of its smallest and second-smallest eigenvalues. The eigenvector of K(\theta) corresponding to the smallest eigenvalue must be associated with the estimator of W , written in lexicographic order. Using the

Read the complete text