Absolute frequency measurement of a Lu + ( 3 D 1 ) optical frequency standard via link to international atomic time Journal: \MET

2025

Read Absolute frequency measurement of a Lu + ( 3 D 1 ) optical frequency standard via link to international atomic time Journal: \MET (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-10004.txt.

Introduction

Zhao Zhang and co-authors report in a 2025 paper the first absolute frequency measure of a lutetium ion optical clock. The standard rests on a hyperfine averaged jump between two states of the ion. Pinning its exact frequency anchors the clock to world time standards.

A single ion clock ran in bursts over three months, totaling 162 hours of uptime. The measured value lands near 353,638,794,073,800 hertz with tiny fractional doubt. That doubt sits at 9.2 parts in ten to the sixteenth, a fine figure. Traceability runs through a remote link to International Atomic Time. No absolute value for this clock type had been published before.

Catalog record

YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE34 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2502-10004

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Absolute frequency measurement of a Lu + ( 3 D 1 ) optical frequency standard via link to international atomic time Journal: \MET Abstract We report on an absolute frequency measurement of the Lu + ( 3 D 1 ) {\rm Lu}^{+}\,(^{3}\rm D_{1}) standard frequency which is defined as the hyperfine-average of S 0 1 {}^{1}\rm S_{0} to D 1 3 {}^{3}\rm D_{1} optical clock transitions in Lu + 176 {}^{176}{\rm Lu}^{+} . The measurement result of 353 638 794 073 800.35 ​ ( 33 ) 353\,638\,794\,073\,800.35(33) Hz with a fractional uncertainty of 9.2 × 10 − 16 9.2\times 10^{-16} was obtained by operating a single-ion Lu + 176 {}^{176}{\rm Lu}^{+} frequency standard intermittently over 3 months with a total uptime of 162 hours. Traceability to the International System of Units (SI) is realized by remote link to International Atomic Time. This is the first reported absolute frequency value for a Lu + ( 3 D 1 ) {\rm Lu}^{+}\,(^{3}\rm D_{1}) optical frequency standard. Keywords: frequency standards, lutetium ion, optical clock, international atomic time \ioptwocol 1 Introduction The International System of Units (SI) defines the second by the duration of a fixed number of oscillation periods of the caesium ( {}^{133}\rm Cs ) ground-state hyperfine transition. The best primary frequency standards (PFS) to realize the SI second are Cs fountains with an inaccuracy near one part in 10^{-16} [ 1 , 2 ] . Several frequency standards based on optical transitions of different ions and atoms now report uncertainties near one part in 10^{-18} [ 3 , 4 , 5 , 6 , 7 , 8 , 9 ] and a roadmap to the redefinition of the SI second has been devised [ 10 ] . The International Committee for Weights and Measures (CIPM) already maintains a list of recommended values for standard frequencies, many recognized as secondary representations of the second (SRS). Some optical clocks based on SRS reference transitions are officially recognized as secondary frequency standards (SFS) and in recent years contribute to the steering of International Atomic Time (TAI) through reporting of measurements to the International Bureau of Weights and Measures (BIPM). For a recently established optical clock species such as Lu + , absolute frequency measurements are necessary for CIPM to establish a recommended value, which are prerequisite to becoming a SRS. Figure 1: (a) Energy level structure of {}^{176}\mathrm{Lu}^{+} . (b) Microwave and optical transitions used in the clock interrogation sequence. (c) Clock interrogation sequence for hyperfine averaging with hyper-Ramsey spectroscopy. The {}^{1}\rm S_{0} to {}^{3}\rm D_{1} transition of {}^{176}{\rm Lu}^{+} is a promising reference for which \lesssim 10^{-18} uncertainty can be realized with relative ease [ 8 ] . We report on the first absolute frequency measurement of the Lu + ( 3 D 1 ) optical standard. In section 2 , we outline the {}^{176}{\rm Lu}^{+} clock operation and the frequency measurement scheme to link to the SI second. In section 3 we detail the frequency shifts and uncertainties for the {\rm Lu}^{+} clock. In section 4 , we analyze the uncertainty contributions from each step of the frequency chain. Finally we discuss results in section 5 . Figure 2: Remote comparison of the lutetium clock to international atomic timescales for absolute frequency evaluation. The optical clock is compared to a hydrogen maser which serves as the local flywheel. The hydrogen maser is linked to the timescale of a remote laboratory, UTC(USNO), via GPS link. UTC(USNO) is linked to TAI and the SI second through the circular T reports of BIPM. 2 Experimental System and Methods 2.1 {}^{176}{\rm Lu}^{+} optical frequency standard Experiments are performed with a single {}^{176}\mathrm{Lu}^{+} ion in a linear Paul trap denoted as Lu-2 [ 8 , 11 ] . Figure 1 (a) shows the energy levels and transitions relevant for laser cooling, trapping, and state manipulation. For {}^{176}\mathrm{Lu}^{+} hyperfine averaging is used to realize an effective J=0 level which practically eliminates second-order Zeeman shifts, and shifts arising from rank 2 tensor interactions, such as the electric quadrupole moment [ 12 ] . The reference frequency, f_{\mathrm{Lu}} , of the {\rm Lu}^{+}\,(^{3}\rm D_{1}) standard is thus defined as the average of the three optical transitions from |\,g\,\rangle\equiv|\,^{1}S_{0},7,0\,\rangle to the hyperfine states |\,F\,\rangle\equiv|\,^{3}D_{1},F,0\,\rangle where F=6,7, and 8 . This average can be conveniently realized using a hybrid microwave and optical interrogation [ 13 ] . As illustrated in figure 1 (b-c), the interrogation sequence consists of an optical Ramsey interrogation on the |\,g\,\rangle\leftrightarrow|\,8\,\rangle transition, where additional microwave pulses transfer population between the hyperfine states during the interrogation time. Their timing is chosen such that the effective time in each of the hyperfine states is the same. When the laser is servoed to the central fringe of the resulting Ramsey spectrum, the hyperfine-averaged (HA) clock frequency is given by f_{\mathrm{Lu}}=\frac{1}{3}(\nu_{8}+\nu_{7}+\nu_{6})=\nu_{L}+\frac{1}{3}(2f_{1}+f_{2}), (1) where \nu_{F} is the resonant frequency of the |\,g\,\rangle\leftrightarrow|\,F\,\rangle optical transition, \nu_{L}=\omega_{L}/(2\pi) is the frequency of the probe light, and f_{k}=\omega_{k}/(2\pi) for k=1,2 are the microwave frequencies used within the interrogation sequence. Even if the microwave fields are not exactly resonant, the interrogation sequence ensures \nu_{L}+(2f_{1}+f_{2})/3 represents the HA clock frequency, as indicated by ( 1 ) [ 8 , 13 ] . Each experiment starts with Doppler cooling on the 646 nm transition followed by preparation in the |\,^{3}D_{1},8,0\,\rangle state and then the Ramsey interrogation sequence as shown in figure 1 (c). The timing parameters used for the Ramsey interrogation are \tau_{\mathrm{L}}=1.4\,\,\mathrm{ms} , and \tau_{1}=\tau_{2}=2\,\,\mathrm{ms} with total Ramsey interrogation time T_{\mathrm{R}}=3(T+\tau_{1}+\tau_{2})=42\,\,\mathrm{ms} . The additional 848-nm \pi -pulse before the end of the sequence shown in figure 1 (c), is phase shifted by 180 ∘ and included for suppressing the remaining probe light induced ac Stark shift by the hyper-Ramsey method [ 14 , 15 ] . A frequency discriminator for locking to the central Ramsey fringe is generated by repeating the entire sequence twice per cycle, alternating the phase shift on the first \pi/2 -pulse by \pm{90}^{\circ} [ 15 ] . Every N=25 cycles, which takes t_{u}=3.6 seconds, the 848 nm laser frequency is steered to maintain the condition given by ( 1 ). For the Ramsey time used here, clock interrogation accounted for 60% of the duty cycle, with the remaining time allocated to cooling (10 ms), state preparation (5 ms), and detection (1 ms). The microwave frequencies f_{1} and f_{2} remain fixed throughout all measurements. All synthesized rf offsets and the microwave frequencies are referenced to the hydrogen maser (Microchip MHM-2010). The clock laser near 848 nm is an external cavity diode laser which is stabilized to a 10-cm ultra low expansion (ULE) optical cavity with finesse of 400000. This cavity is under vacuum at 1\times 10^{-7} mbar and actively temperature stabilized to 33.2 ∘ C, corresponding to its zero coefficient of thermal expansion point. A wideband fiberized electro-optic modulator (EOM) is used to frequency offset the clock laser from the optical reference cavity. The radio-frequency (rf) driving the EOM is generated by a direct digital synthesizer (DDS) which both continuously compensates the long term linear creep of the ULE cavity of 40 mHz s -1 and applies the phase-continuous frequency corrections when servoing to the atomic reference. An instability of 1.5\times 10^{-15} at 1 s was