Wireless and passive pressure detection using magneto-mechanical resonances in process engineering
Timo Merbach, Felix Kexel, Jonas Faltinath, Martin Möddel, Michael Schlüter, Tobias Knopp, Fabian Mohn · 2025
Read Wireless and passive pressure detection using magneto-mechanical resonances in process engineering by Timo Merbach, Felix Kexel, Jonas Faltinath, Martin Möddel, Michael Schlüter, Tobias Knopp, Fabian Mohn (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-09575.txt.
Introduction
Timo Merbach and co-authors present a 2025 paper on wireless pressure sensing. Their sensor is a magneto-mechanical resonator that needs no battery or wire. Pressure bends a printed flexible membrane, which shifts the device's resonance pitch. Pitch shifts reveal the pressure. Membrane thickness sets how sensitive the sensor is, so it can be tuned per job. The team built the sensor for process engineering settings.
Static and dynamic tests measured sensitivity and time response. The lowest sensitivity found was a small fraction of a hertz per millibar. Results matched theory and bench checks well. Readout ran at up to two times per second in this study. Heat effects on the sensor were also probed. Plant engineers get a passive sensor for spots where wires and batteries fail. Sealed tanks and moving parts are natural homes for such a device.
Catalog record
| CREATOR | Timo Merbach, Felix Kexel, Jonas Faltinath, Martin Möddel, Michael Schlüter, Tobias Knopp, Fabian Mohn |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 38 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-09575
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Wireless and passive pressure detection using magneto-mechanical resonances in process engineering Timo Merbach, Felix Kexel, Jonas Faltinath, Martin Möddel, Michael Schlüter, Tobias Knopp, Fabian Mohn Abstract A custom-developed magneto-mechanical resonator (MMR) for wireless pressure measurement is investigated for potential applications in process engineering. The MMR sensor utilises changes in the resonance frequency caused by pressure on a flexible 3D printed membrane. The thickness of the printed membrane plays a crucial role in determining the performance and sensitivity of MMRs, and can be tailored to meet the requirements of specific applications. The study includes static and dynamic measurements to determine the pressure sensitivity and temporal resolution of the sensor. The results show a minimum sensitivity of 0.06 Hz mbar − 1 0.06\penalty\ \text{Hz mbar}^{-1} and are in agreement with theoretical calculations and measurements. The maximum sensor readout frequency is 2 Hz in this study. Additionally, the temperature dependence of the sensor is investigated, revealing a significant dependence of the resonance frequency on temperature. The developed MMR offers a promising and versatile method for precise pressure measurements in process engineering environments. MMR magneto-mechanical resonator Rx receive window SNR signal-to-noise ratio Tx transmit window Keywords : pressure sensor, magneto-mechanical resonator, sensing, resonance frequency, magnet-to-magnet distance \ioptwocol 1 Introduction In process engineering, hydrodynamic process data, such as residence times, mixing times, and volume flow exchange rates, are crucial for scale-up, process control, and optimisation [ 1 , 2 , 3 ] . In both industrial and academic settings, conventional sensors are typically mounted on the exterior of the vessel and rely on a Eulerian approach for tracking. In contrast, Lagrangian sensors are deployed directly within the moving fluid inside the vessel, providing insights into the internal process conditions. Numerous research groups are actively developing such sensors, namely Lagrangian sensor particles, particularly for the application in bioreactors [ 4 , 5 , 6 , 7 , 8 ] . A significant challenge with these sensors lies in determining their position within the vessel. Currently, only axial sensor data—obtained via optical access or hydrostatic pressure—can be utilised for this purpose [ 5 , 6 , 7 ] . Furthermore, energy supply of active sensors is challenging [ 9 ] . The medical field is also confronted with the challenge of monitoring the position and orientation of medical instruments within the human body, necessitating the acquisition of radial and axial information. In response to this need, a novel wireless and passive sensor based on magneto-mechanical resonance was recently introduced [ 10 ] . While this sensor is focused on miniaturisation for medical applications such as endoscopy, surgery, implantation, and vascular interventions to measure position and orientation (6 degrees of freedom), it also has huge potential for technical applications such as process engineering for which is has not yet been utilised so far. In short, the so-called magneto-mechanical resonator (MMR) can be used for tracking by measuring its directional response to a weak magnetic field excitation. In addition, the MMR allows for sensing, since the internal magnet distance affects its resonance frequency [ 11 ] . Coupling this distance to an additional mechanical sensing mechanism allows for determining an environmental parameter such as temperature, pressure, magnetic fields or viscosity. One crucial aspect of data analysis is the possibility of co-registering wireless sensor data with spatial tracking information. As demonstrated in [ 10 ] , spatial tracking with MMRs has been successfully achieved. However, the integration of tracking and sensing processes introduces additional challenges in signal processing that are beyond the scope of the present study. Instead, the study is focused solely on investigating the sensing capabilities of the MMR sensor in the context of process engineering as a proof of concept. Such applications present a number of additional challenges, including electromagnetic interference, distorted supply currents, non-transparent stainless-steel vessels, and extreme temperature as well as pressure conditions. Consequently, this study develops and tests an MMR sensor for measuring pressure in a liquid column under a range of such conditions. It focuses on the sensor’s sensitivity, measurement range, real-time accuracy, and temperature cross-sensitivity. Three experimental approaches are used: static experiments with constant pressure, dynamic experiments measuring pressure variation, and temperature-changing MMR tests. Figure 1: Test bench for hydrostatic and hydrodynamic experiments. Schematic flow diagram of the test bench detailing the column, reservoir, and associated peripheral systems. 2 Material and methods A refillable acrylic column is employed to establish different pressure levels on the MMR, while the passive natural resonance of the MMR is excited inductively and received using a set of coils, located on the outside of the column. The following sections will provide a detailed explanation of each component of the setup. 2.1 Hydrodynamic setup Figure 1 shows the schematic flow diagram of the test bench. A transparent cylindrical column with an inner diameter D_{\text{C}}=70\penalty\ \text{mm} is employed for the experiments. The column has a height of h_{\text{C}}=1.5 m, with an attached hose extending the column to a total of 6 m. This setup follows the Pascal’s paradox, where the pressure depends solely on the height of the column, regardless of the tank’s volume or shape [ 12 , 13 ] . A measuring tape is affixed externally along the full length to facilitate optical height measurement (with an uncertainty of \pm 1 cm), thereby enabling subsequent hydrostatic pressure determination. Additionally, due to the optical access provided by the column and the MMR, a camera using backlight imaging is employed to analyse the edge-to-edge distance d_{\text{e}} between the magnets during the experiment, thus offering further validation of the measurement principle. The column is filled with deionised water maintained at a constant temperature T=(21.1\pm 0.5)\ ^{\circ}\text{C} , with a corresponding fluid density \rho=(998.0\pm 0.1)\ \text{kg m}^{-3} [ 14 ] . A reservoir ( D_{\text{R}}=0.29\penalty\ $\mathrm{m}$,h_{\text{R}}=2.0\penalty\ $\mathrm{m}$ ) is connected to the column in order to supply the latter with deionised water, with the two components connected by the principle of communicating liquid levels. The deionised water is conditioned to ambient temperature over several hours in the reservoir of the test bench, ensuring thermal equilibrium between deionised water and surrounding air. This preparation eliminates thermal effects in the column and MMR, preventing temperature-induced variations in the results. In some static experiments, unconditioned deionised water is used, given the reservoir height is below the maximum height of the test bench. The added volume of the unconditioned water is minimal, as the column is already filled, and the inner diameters of the hoses located above it are significantly smaller ( D_{\text{C}}\gg D_{\text{H}}=9\penalty\ $\mathrm{mm}$ ). Additionally, a waiting period allows temperature differences to equilibrate. The MMR is mounted to the base of a column at a height h_{\text{MMR, Ref}}=0.53 m above the outlet. Figure 2 (a) shows the configuration surrounding the MMR, depicting its arrangement in the test bench. Dynamic experiments will be conducted, where the inlet and outlet dynamics are characterised. In the case of the inlet dynamics, the column is fed from the reservoir, which has a significantly larger volume. For the outlet dynamics, the outlet of the column is connected to a hose assembly, located beneath the column, as shown in Figure 1 . The hoses also have an inner diameter of D_{\text{H}}=9 mm. The segment of the assembly corresponding