Wetting simulation of the porous structure of a heat pipe using an eXtended Discontinuous Galerkin Method and a Parameterized Level-Set
Irina Shishkina \orcidID 0000-0002-1094-8386 and Matthias Rieckmann \orcidID 0000-0003-2199-9573 and Martin Oberlack \orcidID 0000-0002-5849-3755 and Florian Kummer \orcidID 0000-0002-2827-7576 · 2025
Read Wetting simulation of the porous structure of a heat pipe using an eXtended Discontinuous Galerkin Method and a Parameterized Level-Set by Irina Shishkina \orcidID 0000-0002-1094-8386 and Matthias Rieckmann \orcidID 0000-0003-2199-9573 and Martin Oberlack \orcidID 0000-0002-5849-3755 and Florian Kummer \orcidID 0000-0002-2827-7576 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-09301.txt.
Introduction
Shishkina and co-authors simulate in 2025 how liquid wets the porous wick inside a heat pipe, a sealed tube that moves heat with no pump. Their math keeps a sharp border between liquid and vapor, which can pinch where the border meets the wall. High accuracy methods suffer most at that pinch and demand tiny time steps.
Their fix writes the border as one smooth formula set by a few time varying numbers. The simple form steadies the solver and allows larger steps. The flow method itself is a high order scheme built for cut cells. Runs cover wicking with and without evaporation.
Catalog record
| CREATOR | Irina Shishkina \orcidID 0000-0002-1094-8386 and Matthias Rieckmann \orcidID 0000-0003-2199-9573 and Martin Oberlack \orcidID 0000-0002-5849-3755 and Florian Kummer \orcidID 0000-0002-2827-7576 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2502-09301
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Wetting simulation of the porous structure of a heat pipe using an eXtended Discontinuous Galerkin Method and a Parameterized Level-Set Irina Shishkina \orcidID 0000-0002-1094-8386 and Matthias Rieckmann \orcidID 0000-0003-2199-9573 and Martin Oberlack \orcidID 0000-0002-5849-3755 and Florian Kummer \orcidID 0000-0002-2827-7576 Abstract We perform high-order simulations of two-phase flows in capillaries, with and without evaporation. Since a sharp-interface model is used, singularities can arise at the three-phase contact line, where the fluid-fluid interface interacts with the capillary wall. These singularities are especially challenging when a highly accurate, high-order method with very little numerical diffusion is used for the flow solver. In this work, we employ the eXtended Discontinuous Galerkin (XDG) method, which has a very high accuracy but a severe limit regarding e.g., the time-step restriction. To address this challenge and enhance the stability of our numerical method we introduce a novel approach for representing a moving interface in the case of two-phase flows. We propose a global analytical representation of the interface-describing level-set field, defined by a small set of time-dependent parameters. Noteworthy for its simplicity and efficiency, this method effectively addresses the inherent complexity of two-phase flow problems. Furthermore, it significantly improves numerical stability and enables the use of larger time steps, ensuring both reliability and computational efficiency in our simulations. We compare different analytic expressions for level-set representation, including the elliptic function and the fourth-order polynomial, and validate the method against established literature data for capillary rise, both with and without evaporation. These results highlight the effectiveness of our approach in resolving complex interfacial dynamics. 1 Introduction Capillaries play a crucial role in various technological applications due to their unique properties in fluid dynamics. In medical technology, capillaries are integral to microfluidic devices, which are used for lab-on-a-chip applications, enabling rapid and efficient analysis of small fluid samples. In the energy sector, they are essential in the design of heat pipes used for efficient cooling of electric motors, as they facilitate effective heat transfer and distribution [ 3 ] . Gaining insights into the transport dynamics at the liquid-vapor interface in capillaries within the porous wick structure of heat pipes, as well as their wetting characteristics, is crucial. This understanding plays a significant role in precisely determining the operational conditions of heat pipes and in evaluating the capillary dry-out limitations [ 15 ] . These tiny structures also find applications in ink jet printing technology, where capillary action is used to precisely control the flow of ink onto the printing substrate. Overall, the understanding and manipulation of capillaries and their action are vital in advancing these technologies and improving their efficiency and effectiveness. In the capillary simulations, accurately modeling the movement of the interface between liquid and vapor in two-phase flow is essential. Various approaches have been developed to achieve this. In computational fluid dynamics, the two primary models for representing the interface are the diffusive and sharp interface models. Diffusive interface models [ 8 ] represent the interface as a smooth, transitional zone where fluid properties gradually change. In contrast, sharp interface models [ 20 ] treat the interface as an extremely thin and well-defined, where fluid properties change abruptly. Each of this methods has its own set of advantages and challenges. Diffusive interface models able to handle complex interface shapes and more numerically stable, but it may sacrifice some physical accuracy and require more computational resources. On the contrary, sharp interface models offer a high level of physical accuracy but can be computationally demanding. Furthermore, these models are operationally executed through either interface tracking or interface capturing methods [ 22 ] . Interface tracking methods explicitly track the interface’s position and shape, using a network of discrete points or a mesh that moves with the fluid. On the other hand, capturing methods implicitly define the interface within the computational grid without explicitly tracking its position. These methods use a field variable (like volume fraction or a level set function) to indicate the presence of different fluids in each computational cell. Examples include the front tracking method for interface tracking, and the volume of fluid and level-set methods for interface capturing. The selection of a suitable method is dictated by the specific requirements of the simulation, including factors like desired accuracy, available computational resources, and the type of physical phenomena being modeled. In our research, we utilize the level-set method for two-phase flow simulations. This method characterizes the boundary between two fluids using a signed distance function, which has a value of zero at the boundary and varies in the adjacent fluid phases [ 18 ] . For mathematical discretization, we employ the Extended Discontinuous Galerkin (XDG) method, developed by Kummer [ 10 ] , which draws on ideas from the extended finite element method (XFEM) [ 11 ] and also known as cut-cell DG or unfitted DG [ 12 ] . XDG is notable for its high-order approximation of the boundary and a quadrature technique tailored for domains defined indirectly. The discretization process in this approach is executed using the Symmetric Interior Penalty (SIP) method. In our simulations, we encounter a significant challenge due to the existence of a three-phase contact line, which presents a complex issue. One of the primary challenges associated with the contact line is the stress singularity that arises when applying classical hydrodynamic models, particularly the no-slip boundary condition. This condition leads to a non-integrable stress singularity at the contact line, resulting in unphysical predictions regarding the forces required to move the contact line [ 19 ] , [ 7 ] . The classical models fail to account for the complex interactions at the three-phase contact line, which can lead to significant discrepancies between theoretical predictions and experimental observations [ 19 ] , [ 14 ] . One of the key aspects of the moving contact line problem is the dependence of the dynamic contact angle on the speed of the contact line. In their work, Eggers et. al. [ 1 ] describe how the dynamic contact angle can be expressed in terms of characteristic lengths influenced by the capillary number, which reflects the balance between viscous and surface tension forces. This relationship is critical for understanding how the contact angle evolves as the contact line moves, especially under varying flow conditions. Additionally, authors [ 5 ] discuss the relaxation dynamics of moving contact lines, noting that the behavior of advancing and receding contact lines can differ significantly, which has implications for the modeling of dynamic wetting processes. Interactions at the interface involve a complex array of physical phenomena that significantly influence the behavior of the contact line. These include surface tension, which manifests as capillary effects, and viscous forces, both of which are critical in determining the flow dynamics near the contact line. Additionally, when volatile liquids are involved, phase changes such as evaporation or condensation become significant, further complicating the modeling process. The cumulative impact of these forces varies depending on the specific properties of the interacting phases, making the accurate modeling of flow behavior near the contact line particularly challenging [ 4 ] . Additionally, issues with numerical stability and convergence arise. We must consider the capillary time step limitation [ 2 ] to ensure the stability of our numerical