Read A Physics-Informed Deep Learning Model for MRI Brain Motion Correction (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-09296.txt.

Introduction

Mojtaba Safari and co-authors clean motion blur from brain MRI with a physics-informed network. Long scans invite head moves, and moves smear the image. Their 2025 model, PI-MoCoNet, works in two stages. A first network sniffs out which raw signal lines the motion spoiled. A second network, part transformer, rebuilds a clean image. Three losses keep the rebuild honest to the raw data and to how brains look.

On two scan sets the gains were large. Sharpness scores jumped and error rates fell hard at every blur level. Rival image tools trailed. Part-removal tests confirmed each design piece earns its place. Cleaner scans mean fewer repeat visits and surer reads for doctors.

Catalog record

YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE31 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2502-09296

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Physics-Informed Deep Learning Model for MRI Brain Motion Correction Abstract Background: Magnetic resonance imaging (MRI) is an essential brain imaging tool, but its long acquisition times make it highly susceptible to motion artifacts that can degrade diagnostic quality. Purpose: This work aims to develop and evaluate a novel physics-informed motion correction network, termed PI-MoCoNet, which leverages complementary information from both the spatial and k -space domains. The primary goal is to robustly remove motion artifacts from high-resolution brain MRI images without explicit motion parameter estimation, thereby preserving image fidelity and enhancing diagnostic reliability. Materials and Methods: PI-MoCoNet is designed as a dual-network framework consisting of a motion detection network and a motion correction network. The motion detection network employs a U-net architecture to identify corrupted k -space lines using a spatial averaging module, thereby reducing prediction uncertainty. The correction network, inspired by recent advances in U-net architectures and incorporating Swin Transformer blocks, reconstructs motion-corrected images by leveraging three loss components: the reconstruction loss ( ℒ 1 \mathcal{L}_{1} ), a learned perceptual image patch similarity (LPIPS) loss, and a data consistency loss ( ℒ dc \mathcal{L}_{\text{dc}} ) that enforces fidelity in the k -space domain. Realistic motion artifacts were simulated by perturbing phase encoding lines with random rigid transformations. The method was evaluated on two public datasets (IXI and MR-ART). Comparative assessments were made against baseline models, including Pix2Pix GAN, CycleGAN, and a conventional U-net, using quantitative metrics such as peak signal-to-noise ratio(PSNR), structural similarity index measure (SSIM), and normalized mean square error (NMSE). Results: PI-MoCoNet demonstrated significant improvements over competing methods across all levels of motion artifacts. On the IXI dataset, for minor motion artifacts, PSNR improved from 34.15 dB in the motion-corrupted images to 45.95 dB after correction, SSIM increased from 0.87 to 1.00, and NMSE was reduced from 0.55% to 0.04%. For moderate artifacts, PSNR increased from 30.23 dB to 42.16 dB, SSIM from 0.80 to 0.99, and NMSE from 1.32% to 0.09%. In the case of heavy artifacts, PSNR improved from 27.99 dB to 36.01 dB, SSIM from 0.75 to 0.97, and NMSE decreased from 2.21% to 0.36%. On the MR-ART dataset, PSNR values increased from 23.15 dB to 33.01 dB for low artifact levels and from 21.23 dB to 31.72 dB for high artifact levels; concurrently, SSIM improved from 0.72 to 0.87 and from 0.63 to 0.83, while NMSE decreased from 10.08% to 6.24% and from 14.77% to 8.32%, respectively. An ablation study further confirmed that incorporating both data consistency and perceptual losses led to an approximate 1 dB gain in PSNR and a reduction of 0.17% in NMSE compared to using the reconstruction loss alone. Conclusions: PI-MoCoNet is a robust, physics-informed framework for mitigating brain motion artifacts in MRI. It successfully integrates spatial and k -space information to enhance image quality. Its superior performance over comparative methods highlights its potential for clinical application, particularly in settings where patient motion is unavoidable. The source code is available at: https://github.com/mosaf/PI-MoCoNet.git . Mojtaba Safari, Shansong Wang, Zach Eidex, Richard Qiu, Chih-Wei Chang, David S. Yu, Xiaofeng Yang, PhD ‡ Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322, United States of America ‡ Corresponding Author Author to whom correspondence should be addressed. email: [email protected] keywords: k -space, MRI, motion correction, MoCo, physics informed deep learning, deep learning 1 Introduction Motion artifacts are among the most common and challenging distortions in high-resolution brain Magnetic resonance imaging (MRI) images, often arising from both involuntary and voluntary patient movements 1 . MRI is a key modality for generating functional and anatomical images that inform diagnosis, treatment, and prognosis; for example, high-resolution brain anatomical MRI is used extensively to delineate tumor subregions and monitor post-treatment outcomes 2 , 3 , 4 , 5 . However, the inherently long acquisition times of MRI greatly increase the likelihood of patient motion, which disrupts spin history, leads to signal loss, and alters the B 0 field, leading to susceptibility artifacts 6 . Severe motion also causes inconsistencies in k -space, potentially violating the Nyquist criterion 7 , which causes image ghosting and blurring. Deep learning (DL) algorithms have achieved remarkable success in medical imaging and treatment 8 . Studies have proposed both supervised and unsupervised DL approaches to remove motion artifacts 9 . These methods are trained in the image domain to learn a mapping from motion-corrupted to motion-free space by training a network f_{\nu}:\mathcal{T}_{a}\to\mathcal{T} , where \mathcal{T}_{a} and \mathcal{T} are motion-corrupted and motion-free spaces, respectively 10 , 11 , 12 . While these techniques can effectively recover motion-free images, their exclusive reliance on the image domain may lead to image hallucinations, particularly under severe motion conditions 13 . In contrast, several studies have attempted to correct motion artifacts by estimating rigid motion parameters (e.g., translation and rotation) and applying corrections using compressed sensing MRI algorithms 14 , 15 . Although these methods leverage the localized nature of motion artifacts in k -space, they can be lengthy and limited to raw k -space data that are not available to end users. In addition, the spatial domain representing images provides complementary information that can improve the MoCo models, which might be overlooked by these studies. In this work, we propose a physics-informed motion correction network (PI-MoCoNet) that leverages both spatial and k -space domain information to remove brain motion artifacts. Our approach avoids explicit motion parameter estimation, enabling potential extension to non-rigid motions such as coherent lung motion. Our key contributions are as follows: 1. We develop a realistic motion artifact simulation framework that mimics the actual motion-induced distortions observed in clinical MRI. 2. We design a novel variation of the U-net architecture inspired by Yue et al. 16 , in which traditional attention layers are replaced by Swin Transformer blocks to enhance feature representation. 3. Our proposed PI-MoCoNet exploits k -space data to predict corrupted lines and enforces data consistency, thereby preserving data fidelity during motion correction. 2 Materials and Methods 2.1 Problem formulation The spine echo MRI acquisition signal for each phase encoding line of a sample can be written as follows: \centering s(k_{x},k_{y})=\int\int\rho(x,y)e^{-i2\pi(k_{x}x+k_{y}y)}=\mathcal{F}[\rho(x,y)]\@add@centering (1) where s\in\mathbb{C}^{N_{x}\times N_{y}} represents the measured k -space data, k_{x}\in\mathbb{R}^{N_{x}} and k_{y}\in\mathbb{R}^{N_{y}} are the frequency and phase encoding directions, and \rho\in\mathbb{C}^{N_{x}\times N_{y}} encapsulates the combined effects of the receive field, spin density, and the gain of the MRI system. Here, \mathcal{F} denotes the Fourier transform 17 . During patient motion, some phase encoding lines (i.e., k_{y} lines) are displaced. These displacements in k -space induce artifacts in the reconstructed images, manifesting as blurring, ghosting, or ringing, depending on the location of the affected lines 18 . Motivated by the localized nature of motion artifacts in k -space, we hypothesize that enforcing data consistency (DC) of the corrupted k -space lines can effectively restore image fidelity. 2.2 PI-MoCoNet Our proposed PI-MoCoNet consists of two interconnected networks: a motion detection network \mathcal{D}_{\theta} and a motion correction network \mathcal{C}_{\nu} . These networks are trained simultaneously to detect the corrupted k -space lines and correct them, respectively. Figure 1 provides an overview of the proposed framework. Figure 1: Flowchart of the proposed PI-MoCoNet framework. (a) The motion detection network \mathcal{D}_{\theta} identifies corrupted regions in the frequency domain, producing

Read the complete text