Supplementary Information: Ferri- and Ferro-Electric Switching in Spontaneously Chiral Polar Liquid Crystals

Jordan Hobbs 1, Calum J. Gibb 2, Richard. J. Mandle 1,2 · 2025

Read Supplementary Information: Ferri- and Ferro-Electric Switching in Spontaneously Chiral Polar Liquid Crystals by Jordan Hobbs 1, Calum J. Gibb 2, Richard. J. Mandle 1,2 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2502-08551.txt.

Introduction

Jordan Hobbs, Calum Gibb, and Richard Mandle report electric switching in a chiral liquid crystal in this two thousand twenty-five paper, presented as supplementary information for a larger study. Some liquid crystals break mirror symmetry on their own and carry electric order. The first molecule found to do this forms layered phases that twist into helices. Their textures change strongly with heating history and phase order.

Electric field tests show the two chiral phases switch in unlike ways. One flips smoothly with no threshold or lag. The other needs a clear push and lags, a pseudo-ferrielectric style never seen in such phases. Helix growth can also jump or glide depending on conditions. The findings matter for future soft-matter devices.

Catalog record

CREATORJordan Hobbs 1, Calum J. Gibb 2, Richard. J. Mandle 1,2
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE20 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2502-08551

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Supplementary Information: Ferri- and Ferro-Electric Switching in Spontaneously Chiral Polar Liquid Crystals Jordan Hobbs 1, Calum J. Gibb 2, Richard. J. Mandle 1,2 Abstract Contents 1. Supplementary methods 2. Supplementary results 3. Organic synthesis 4. Supplementary References 1 Supplementary Methods 1.1. Chemical Synthesis Chemicals were purchased from commercial suppliers (Fluorochem, Merck, ChemScene, Ambeed) and used as received. Solvents were purchased from Merck and used without further purification. Reactions were performed in standard laboratory glassware at ambient temperature and atmosphere and were monitored by TLC with an appropriate eluent and visualised with 254 nm light. Chromatographic purification was performed using a Combiflash NextGen 300+ System (Teledyne Isco) with a silica gel stationary phase and a hexane/ethyl acetate gradient as the mobile phase, with detection made in the 200-800 nm range. Chromatographed materials were filtered through 200 nm PTFE frits and then subjected to re-crystallisation from an appropriate solvent system. 1.2. Chemical Characterisation Chemical materials were characterised by NMR spectroscopy using a Bruker Avance III HDNMR spectrometer operating at 400 MHz, 100.5 MHz or 376.4 MHz (1H, 13C1H and 19F, respectively). High resolution mass spectrometry data (HRMS) was collected using a Bruker MaXis Impact spectrometer with a negative ESI source (VIP-HESI); the sample was introduced via direct infusion as solution in MeCN. HPLC analysis was performed using an Agilent 1290 Infinity II system fitted with a poroshell 120 ec-c18 column running a water:MeCN gradient. 1.3. Thermal Analysis Differential scanning calorimetry (DSC) measurements were performed using a TA Instruments Q2000 DSC instrument (TA Instruments, Wilmslow UK), equipped with a RCS90 Refrigerated cooling system (TA Instruments, Wilmslow UK). The instrument was calibrated against an Indium standard, and data were processed using TA Instruments Universal Analysis Software. Samples were analysed under a nitrogen atmosphere, in hermetically sealed aluminium TZero crucibles (TA Instruments, Wilmslow, UK) and subjected to three analysis cycles. In all cases, samples were subject to heating and cooling at a rate of 10 K min-1. Phase transition temperatures were measured as onset values on cooling cycles for consistency between monotropic and enantiotropic phase transitions, while crystal melts were obtained as onset values on heating. 1.3. Optical Microscopy Polarised light optical microscopy (POM) was performed using a Leica DM2700P polarised light microscope (Leica Microsystems (UK) Ltd., Milton Keynes, UK), equipped with 10x and 50x magnification, and a rotatable stage. A Linkam TMS 92 heating stage (Linkam Scientific Instruments Ltd., Redhill, UK) was used for temperature control, and samples were studied sandwiched between two untreated glass coverslips. Images were recorded using a Nikon D3500 Digital Camera (Nikon UK Ltd., Surbiton, UK), using DigiCamControl software. 1.4. X-ray Scattering X-ray scattering measurements, both small angle (SAXS) and wide angle (WAXS) were recorded using an Anton Paar SAXSpoint 5.0 beamline machine. This was equipped with a primux 100 Cu X-ray source with a 2D EIGER2 R detector. The X-rays had a wavelength of 0.154 nm. Samples were filled into either thin-walled quartz capillaries or held between Kapton tape. Temperature was controlled using an Anton Paar heated sampler with a range of -10 o C to 120 o C and the samples held in a chamber with an atmospheric pressure of <1 mbar. Samples were held at 120 o C to allow for temperature equilibration across the sample and then slowly cooled while stopping to record the scattering patterns. The samples were not formally aligned and so these measurements can be considered as “powder” samples. It should be noted that some spontaneous alignment of the LCs both within the capillaries and between the Kapton tape did occur leading to the classic “lobe” pattern seen in the 2D patterns. 1D patterns were obtained by radially integrating the 2D SAXS patterns. Peak position and FWHM was recorded and then converted into d spacing following Bragg’s law. In the tilted smectic phase, the tilt was obtained from: \frac{d_{c}}{d_{A}}=\cos\theta (1) where d_{c} is the layer spacing in the tilted smectic phase, d_{A} is the extrapolated spacing from the non-tilted preceding phase, extrapolated to account for the weak temperature dependence of the preceding phases due to shifts in conformation and order, and \theta the structural tilt angle. 1.5. Measurement of Spontaneous Polarization (P S ) Spontaneous polarisation measurements are undertaken using the current reversal technique. Triangular waveform AC voltages are applied to the sample cells with an Agilent 33220A signal generator (Keysight Technologies), and the resulting current outflow is passed through a current-to-voltage amplifier and recorded on a RIGOL DHO4204 high-resolution oscilloscope (Telonic Instruments Ltd, UK). Heating and cooling of the samples during these measurements is achieved with an Instec HCS402 hot stage controlled to 10 mK stability by an Instec mK1000 temperature controller. The LC samples are held in 4µm thick cells with no alignment layer, supplied by Instec. The measurements consist of cooling the sample at a rate of 1 Kmin -1 and applying a set voltage at a frequency of 20 Hz to the sample every 1 K. The voltage was set such that it would saturate the measured P S and was determined before final data collection. There are three contributions to the measured current trace: accumulation of charge in the cell (I c ), ion flow (I i ), and the current flow due to polarisation reversal (I p ). To obtain a P S value, we extract the latter, which manifests as one or multiple peaks in the current flow, and integrate as: P_{S}=\int{\frac{I_{p}}{2A}dt} (2) where A is the active electrode area of the sample cell. 1.6. Birefringence Measurements Birefringence was measured using a Berek compensator mounted in a Leica DM 2700 P polarised optical microscope. The birefringence was measured in the centre of the active ITO area for the IPS cells used here. 1.7. Transmission Spectra A microscope equipped coupled to an Avantes AvaSpec-2048 XL spectrometer which used to record transmission spectra of samples. The rubbing direction was set parallel to the light polarization direction, but no analyzer was inserted. A spectra from the phase above the spontaneously chiral phases was used as the reference state of each sample 1.8. Pitch Measurements The pitch was measured by illumination of the sample from the bottom via a 405 nm laser. The angle of diffraction was measured on a flat screen set 1.8cm away from the sample. 2 Supplementary Results Figure S1: POM images of compound 1 in a 5 \mu m thick parallel rubbed planar cell at a) 120 °C in the SmA F phase on heating, b) 150 °C in the SmA phase on heating and c) 120 °C in the SmA F phase on cooling. The blue and purple arrows indicate the polariser axes while the black arrow indicates the rubbing direction. Figure S2: POM images of compound 2 in a 5 \mu m thick parallel rubbed planar cell at a) 105 °C in the N F phase on cooling and b) 104 °C, c) 103 °C, d) 102 °C e) 101 °C and f) 100 °C in the N TBF phase on cooling. The blue and purple arrows indicate the polariser axes while the black arrow indicates the rubbing direction. Figure S3: POM observations of compound 2 in the \text{SmC}_{\text{P}}^{\text{H}} phase at 92 ºC in a 5.5 \mu m parallel rubbed planar aligned cell with

Read the complete text