Read Five-dimensional single-shot fluorescence imaging using a polarized Fourier light-field microscope Journal: arxiv by Oumeng Zhang, Changhuei Yang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-18047.txt.
Introduction
Oumeng Zhang and Changhuei Yang build a microscope that reads five dimensions at once in a 2025 paper. Fast single-shot imaging spares slow scans of living samples. Their scope joins a polarization camera to a light-field design.
One snap yields depth, brightness, and two polarization axes together. A test target with a star pattern confirmed sharp reads across polarization states and a wide depth range. Plant roots then showed split patterns in how their cellulose fibers align by section. The gains suit biology and environmental samples that shift fast. The design marks a step up for single-shot fluorescence work.
Catalog record
| CREATOR | Oumeng Zhang, Changhuei Yang |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 16 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-18047
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Five-dimensional single-shot fluorescence imaging using a polarized Fourier light-field microscope Journal: arxiv Oumeng Zhang, Changhuei Yang Abstract Single-shot fluorescence imaging techniques have gained increasing interest in recent years due to their ability to rapidly capture complex biological data without the need for extensive scanning. In this letter, we introduce polarized Fourier light field microscopy (pFLFM), a novel fluorescence imaging technique that captures five-dimensional information (3D intensity and 2D polarization) in a single snapshot. This technique combines a polarization camera with an FLFM setup, significantly improving data acquisition efficiency. We experimentally validated the pFLFM system using a fluorescent Siemens star, demonstrating consistent resolution and an extended depth of field across various polarizations. Using the 5D imaging capabilities of pFLFM, we imaged plant roots and uncovered unique heterogeneities in cellulose fibril configurations across various root sections. These results not only highlight the potential of pFLFM in biological and environmental sciences, but also represent a significant advancement in the design of single-shot fluorescence imaging systems. Fluorescence imaging stands out as one of the most effective optical imaging techniques across various fields, including biological, biochemical, biomedical, and environmental studies, where it provides unparalleled insights due to its high specificity and sensitivity. Recent technological advances have increasingly focused on computational imaging techniques that enable the capture of multi-dimensional data in a single snapshot. Traditional volumetric fluorescence microscopy methods, such as confocal or light sheet microscopy, typically require scanning to reconstruct 3D structures. This not only complicates the imaging system with the need for multiple moving parts but also extends the time required for data acquisition. In contrast, single-shot volumetric fluorescence (SVF) imaging techniques [ 1 ] offer a promising alternative by encoding 3D information into 2D measurements through the design of the system’s point spread function (PSF). Subsequently, a reconstruction algorithm processes this data to extract the 3D information. In addition to video-rate acquisition capabilities, the simplicity of these setups in some of the latest SVF imaging techniques enable miniaturization [ 2 , 3 , 4 ] , significantly expanding their applicability in in vivo applications. One of the approaches in SVF imaging is Fourier light field microscopy (FLFM) [ 5 , 6 ] . In contrast to traditional light field microscopy [ 7 , 8 , 9 ] , which places a microlens array (MLA) at the image plane to capture light field information, FLFM positions the MLA at the pupil plane of the imaging system. In this configuration, each lenslet in the MLA captures the object from a slightly different angle, creating perspective images at the focal plane of the MLA, all of which are recorded by a single camera. This arrangement mirrors the mechanism of binocular vision, enabling 3D reconstruction of the object. Recent advancements have further improved FLFM’s capabilities. For example, using lenslets with varying focal lengths has extended the depth of field by an order of magnitude [ 10 ] . Additionally, replacing traditional sensors with event cameras allows for ultrafast 3D imaging [ 11 ] . Another significant direction in the advancement of fluorescence imaging technology involves measuring properties beyond the intensity distribution, such as fluorescence lifetime and emission spectrum. Among these, fluorescence polarization is particularly significant because it provides insights into the orientation of fluorophores, which can reveal details about the local biochemical and biophysical environment [ 12 , 13 ] . Briefly, fluorescent molecules can be modeled as oscillating dipoles that emit polarized light, with the emission polarization depending on the orientation of the dipole [ 14 , 15 ] . When fluorophores are randomly oriented within a sample, the resulting fluorescence emission is typically isotropic, showing no preferred polarization direction. In contrast, when fluorophores are more orderly arranged within the local environment, a strong polarization preference in the emitted fluorescence is observed, indicating the structured alignment of these fluorophores. This property has been used to explore various biological phenomena, such as chemical heterogeneities within lipid membranes [ 16 , 17 , 18 ] , the growth and decay of amyloid fibrils [ 19 ] , and conformational changes in DNA structures [ 20 ] . In this letter, we introduce polarized Fourier light field microscopy (pFLFM), a fluorescence imaging technique capable of capturing five-dimensional information (3D intensity and 2D polarization) in a single snapshot. This method integrates a polarization camera with an FLFM setup. We experimentally validated the pFLFM system using a fluorescent Siemens star. Leveraging its 5D imaging capability, we have applied pFLFM to image plant roots, revealing distinct cellulose fibril configurations within various regions of the roots. These results demonstrate the feasibility of 5D single-shot imaging and underscore its biological relevance by providing unprecedented insights into the structural organization and orientation of cellular components. Figure 1: (a) Schematic of the pFLFM system. SMF: single mode fiber; QWP: quarter-wave plate; KL: Köhler lens; OL: objective lens; DM: dichroic mirror; BF: bandpass filter; TL: tube lens; L1-L4: lenses; MLA: microlens array; PolCam: polarization camera. Insets show the alignment of the pupil relative to the lenslets in the MLA and the configuration of polarized pixels in the polarization camera. (b) Image of the pupil and the MLA. (c) Representative image of wheat root captured with the pFLFM system. The field of view in channels (i)-(iv) is set by the iris. Images are color-coded according to the angle of linear polarization (AoLP), degree of linear polarization (DoLP), and Stokes parameter S_{0} (intensity). (d) PSF color-coded with depth z in channels (i)-(iv), which correspond to four sections of the pupil. Scale bar: 500 µm in (b), 200 µm in (c), and 20 µm in (d). The imaging system is shown in Figure 1 a. A 488-nm laser (Thorlabs LP488-SF20G) coupled to a single-mode fiber (SMF) was modulated by lens L1, a quarter-wave plate (QWP) and a Köhler lens (KL). After reflection from a dichroic mirror (DM, Semrock Di01-R488/561), the resulting illumination at the sample was uniform and circularly polarized. A 20x, 0.4-NA objective lens (Olympus PLN20X) and a tube lens (TL, f=150 mm) were used to create an intermediate image plane. An iris was positioned at this plane to adjust the field of view. The captured fluorescence was filtered using a bandpass filter (BF, Semrock FF01-523/610). Lens L2 ( f=40 mm) projected the pupil plane onto a microlens array (MLA, Thorlabs MLA1M), where the pupil was demagnified to align precisely with four lenslets of the MLA (Figure 1 b). A 4f system (L3, f=30 mm and L4, f=80 mm) then magnified and projected the images from the MLA onto a polarization camera (PolCam, The Imaging Source DZK 33UX250). The raw image captured by the polarization camera (Figure 1 c) consists of four sub-images corresponding to pixel intensities along 0°, 45°, 90°, and 135° polarization axes. These polarized images can be used to compute the three Stokes parameters S_{0,1,2} , which can be further mapped to intensity (equal to S_{0} ), angle of linear polarization (AoLP), and degree of linear polarization (DoLP). To visualize these parameters simultaneously, we apply a colormap where color represents the AoLP, saturation represents the DoLP, and brightness represents the intensity [ 21 ] . Specifically, white denotes isotropic polarization, a highly saturated color indicates strong linear polarization along a specific direction, and black represents low