Understanding Surgical smoke in Laparoscopy through Lagrangian Coherent Structures

Sandeep Kumar, Caroline Crowley, Mohammad Faraz Khan, Miguel D. Bustamante, Ronan Cahill, Kevin Nolan · 2025

Read Understanding Surgical smoke in Laparoscopy through Lagrangian Coherent Structures by Sandeep Kumar, Caroline Crowley, Mohammad Faraz Khan, Miguel D. Bustamante, Ronan Cahill, Kevin Nolan (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-16387.txt.

Introduction

Sandeep Kumar and five co-authors trace where surgical smoke drifts during keyhole surgery, so it can be removed before it harms anyone. The smoke, a byproduct of cutting and cauterizing tissue, carries chemicals that endanger patients and staff. Its motion follows the air flow inside the inflated abdomen, and hidden flow structures steer where particles gather. The team computed that flow and mapped the structures, called Lagrangian coherent structures, for a model abdomen.

They first measured how much gas leaves through each outlet, then read the ridge patterns of a stretching field across several slices. Those patterns shifted with the angle, position, and count of the outlets and the inlet. The ridges exposed where vortices form and where smoke piles up most. The authors say the maps can guide where to place instruments for the fastest clearing.

Catalog record

CREATORSandeep Kumar, Caroline Crowley, Mohammad Faraz Khan, Miguel D. Bustamante, Ronan Cahill, Kevin Nolan
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE34 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-16387

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Understanding Surgical smoke in Laparoscopy through Lagrangian Coherent Structures Sandeep Kumar, Caroline Crowley, Mohammad Faraz Khan, Miguel D. Bustamante, Ronan Cahill, Kevin Nolan Abstract . In laparoscopic surgery, one of the main byproducts is the gaseous particles, called surgical smoke, which is found hazardous for both the patient and the operating room staff due to their chemical composition, and this implies a need for its effective elimination. The dynamics of surgical smoke are monitored by the underlying flow inside the abdomen and the hidden Lagrangian Coherent Structures (LCSs) present therein. In this article, for an insufflated abdomen domain, we analyse the velocity field, obtained from a computational fluid dynamics model, first, by calculating the flow rates for the outlets and then by identifying the patterns which are responsible for the transportation, mixing and accumulation of the material particles in the flow. From the finite time Lyapunov exponent (FTLE) field calculated for different planar cross sections of the domain, we show that these material curves are dependent on the angle, positions and number of the outlets, and the inlet. The ridges of the backward FTLE field reveal the regions of vortex formation, and the maximum accumulation, details which can inform the effective placement of the instruments for efficient removal of the surgical smoke. 1. Introduction Minimally Invasive Surgery (MIS), or ‘keyhole’ (laparoscopic) surgery has become increasingly popular, thanks to its effectiveness and economical advantages [ 1 ] . A typical laparoscopic operation involves piercing the human abdomen wall in four or five places through which, surgical instruments including a camera are passed inside the body. The hole thus created, is held open through an inlet port, i.e., the trocar, via which carbon dioxide gas is passed inside the abdomen to maintain a working space (pneumoperitoneum). In this way, with an insufflated abdomen, with more space, the surgeons can operate while viewing the telescopic image via an attached camera and light source connected to a video monitor. Some of the main benefits of laparoscopic surgery compared to conventional surgery are faster recovery and shorter stay at the hospital, reduced scarring due to small wounds, less pain and bleeding post-surgery, thus, a shorter period of short-term disability, etc. Laparoscopic surgery employs long slender surgical instruments that are passed through the valved trocars. These instruments cut the tissues inside the abdomen using a high-frequency alternating electrical current [ 2 ] . The gaseous byproduct of this process is called ‘surgical smoke’ and it not only obscures the surgeon’s vision through the camera, it can be observed that smoke and gas escape through the trocar [ 3 ] . Several studies have addressed the hazardous nature of surgical smoke to the long-term health of surgical teams [ 4 , 5 ] . For instance, the gas leaks have been quantified and well-studied with high-speed Schlieren optical imaging and the latest image processing techniques [ 6 ] . Among other relevant concerns, it is worth mentioning the surgical site infection, which can occur post surgery at the incision port, and is affected by particle distribution inside the the operating room (OR). The later has been well studied highlighting the effects and prevension in [ 7 , 8 , 9 ] . Thus, to ensure the safety of the operating room (OR) staff and environment, a protected and safe MIS is desired and to that end, understanding the dynamics of gas both inside and outside the abdomen becomes very important [ 10 ] . It is also worth pointing out that surgical masks are not traditionally considered Personal Protective Equipment (PPE) but part of the infection control chain for the patient. PPE is the last resort in the hierarchy of controls and this work is motivated by a need for better engineering controls. With this aim, one possible direction is to model the underlying fluid phenomenon mathematically and study the velocity field. To begin with, a natural choice is to employ the Computational fluid dynamics (CFD) based techniques that can describe flow dynamics and the transport of smoke particles as reliable experimental data are sometimes difficult to obtain and can be expensive and time-consuming [ 11 ] . Recently, CFD modelling has been employed to understand the behaviour of surgical smoke as it is released outside the human body [ 12 , 10 ] . For instance, in [ 12 ] , through a numerical model and simulations, smoke generation, evacuation and quantification of its composition have been described as well as compared with experimental data, while [ 10 ] provides novel information about the flow dynamics of gas leaks from trocars during laparoscopic surgery by studying the trajectories of particles ejected in the leaks. On the other hand, equally important and not much addressed is the action of gas as it enters the abdomen, which also influences the movement of smoke particles. In this article, we concentrate on this scenario and analyse different setups of laparoscopic surgery involving a change in positions, angles and number of outlets and the inlet. The latter is important because the configuration of trocars incisions varies from one procedure to another and the angle of the trocars changes throughout an operation as instruments are manipulated. This is essentially an impinging jet problem, which results in the formation of vortical flow structures that will be constrained by the shape of the abdomen and the angle of the inflow jet. Surgical smoke is typically allowed to diffuse within the pneumoperitoneum and then vented into the operating theatre airspace in the breathing zones of theatre staff. Thus, a means to eliminate it at source requires an understanding of the flow dynamics inside the abdomen, which, in turn, would also complement the results in [ 10 ] and provide a complete picture of the surgical smoke problem. Note that from the velocity field calculated from the CFD simulations one can study the particle trajectories; however, the instantaneous velocity field does not always reveal the behaviour of actual trajectories as the instantaneous streamlines can diverge from actual particle trajectories very quickly. Therefore, in a Lagrangian framework, the finite time Lyapunov exponent (FTLE) is defined which is calculated from the particle trajectories and hence, can explain the integrated effect of the flow [ 13 ] . In other words, it measures the amount by which particles separate in a given time interval or a finite time average of the maximum expansion rate for a pair of particles advected in the flow. Indeed, from the FTLE field, which is both space and time-dependent, complex flow patterns such as vortex formation and its development can be detected; moreover, the ridges of the field form separatrices in time-dependent systems, which are called Lagrangian Coherent Structures (LCS) [ 14 ] . These material curves can be identified in both forward and backward FTLE fields and are analogue of stable and unstable manifolds in time-independent systems, respectively, and divide dynamically distinct regions in the flow and reveal geometry which is often hidden when viewing the vector field or even trajectories of the system. Hence, they often provide an effective tool in analyzing systems with general time-dependence, especially for understanding transport of particles [ 15 ] . For instance, their applicability has been

Read the complete text