Measurement of Radon-222 concentration in N 2 using an activated charcoal trap
N. Fatemighomi, Y. Ahmed, S. M. A. Hussain, J. Lu, A. Pearson, J. Suys · 2025
Read Measurement of Radon-222 concentration in N 2 using an activated charcoal trap by N. Fatemighomi, Y. Ahmed, S. M. A. Hussain, J. Lu, A. Pearson, J. Suys (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-14559.txt.
Introduction
Fatemighomi and co-authors describe a better trap for measuring radon gas in nitrogen cover gas, in work from 2025. Radon is a major background in dark matter and neutrino experiments deep underground. Clean nitrogen shields parts of those experiments, but its radon level must be watched closely.
The new trap uses activated charcoal to catch radon from the gas. It was cleaned and tested at the SNOLAB facility in Canada. The team built a radon source to calibrate it and worked out how to measure its efficiency, background, and sensitivity. Sharper assays help experiments prove their shielding gas is clean enough.
Catalog record
| CREATOR | N. Fatemighomi, Y. Ahmed, S. M. A. Hussain, J. Lu, A. Pearson, J. Suys |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-14559
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measurement of Radon-222 concentration in N 2 using an activated charcoal trap N. Fatemighomi, Y. Ahmed, S. M. A. Hussain, J. Lu, A. Pearson, J. Suys Abstract Radon-222 is a limiting background in many leading dark matter and low energy neutrino experiments. One way to mitigate Radon-222 is to fill external experimental components with a clean cover gas such as N 2 . At the SNOLAB facility in Canada, the 222 Rn concentration in the cover gas systems of the experiments are monitored using a radon assay board developed by the SNO collaboration. To improve the sensitivity of N 2 assays, a new trapping mechanism based on activated charcoal has been developed. The trap was purified and tested at SNOLAB. The methods for determining the efficiency, background, and sensitivity of the trap were described. Additionally, as part of the efficiency measurement, a radon calibration source was developed and characterized. Journal: Nuclear Physics A 1 Introduction The purpose of this work is to introduce a method for measuring Radon-222 ( 222 Rn) concentration in the nitrogen (N 2 ) cover gas systems of experiments hosted at SNOLAB, an underground science facility located 2 km deep in the Vale Creighton mine near Sudbury, Ontario. Experiments such as SNO+ [ 1 ] , DEAP-3600 [ 2 ] , and high-purity germanium detectors [ 3 ] use boil-off N 2 from SNOLAB’s liquid nitrogen (LN) plants [ 4 ] and Grade 5 N 2 cylinder cylinders [ 5 ] to control the background induced by 222 Rn progeny. Radon-222 progeny can produce some of the most troublesome radioactive backgrounds for these experiments. 222 Rn is a radioactive noble gas with a half-life of 3.8 days. It is the progeny of 226 Ra in the 238 U decay chain as shown in Figure 1 . 222 Rn can enter detectors through leaks, surface emanation, and diffusion. Figure 1: 238 U decay chain. Accurate measurement of the radon concentration in the cover gas volumes of experiments is crucial, as it helps model their external radon-induced backgrounds. Radon-222 assay refers to the measurement of the concentration of 222 Rn in a given gas or water sample as well as the radon emanation and diffusion rate from a material surface. The SNO collaboration developed a technique to perform material and ultra pure water radon assays [ 6 ] [ 7 ] . In this technique, radon atoms are extracted from a sample material or from water droplets, then trapped in a radon trap which is at -196 \degree C. The radon trap in these two applications is filled with bronze wool and is kept under vacuum. The bronze wool is used to stop the radon atoms by increasing the surface area, while allowing the other gasses such as N 2 and O 2 to pass through. The gas flow rate for these applications is <0.1 standard litter per minute (SLPM). This technique with the bronze wool as radon trapping mechanism initially adopted by the authors to perform N 2 gas assays, in which the gas flow rate is \geq 1 SLPM. However, it was observed that the radon trapping efficiency decreases with the duration that gas flows through the trap [ 8 ] . This limits the maximum volume of N 2 that can be sampled with this technique and, consequently, restricts the assay sensitivity. We hypothesize that this is due to the increasing temperature of the trap as more N 2 passes through, which leads to the releasing of the radon atoms. This observation motivated us to develop and add a new radon trap filled with a material which has higher heat capacity compared to bronze wool and use it as a pre-trap to the existing system. Activated charcoal has at least twice the heat capacity of bronze wool [ 9 ] . Furthermore, activated coconut charcoal, with its high adsorption capabilities, is highly effective at trapping radon atoms and is commonly used in dark matter experiments for gas purification [ 10 ] . Thus, it was a natural candidate to test for N 2 radon assays at SNOLAB. When activated charcoal is used primarily for gas purification, with the goal of preventing any radon atoms from escaping, about a kilogram of this radon adsorbent is used. For our purpose, to achieve the high radon desorption efficiency required for screening radon concentration in gas, the amount of charcoal needed is on the order of grams. For this paper Calgon OVC 4 \times 8 [ 11 ] , which is a granular activated carbon made from coconut shell is used. The charcoal was purified at SNOLAB and then was used to make a radon trap. The background and radon trapping efficiency of the trap were measured. The latter was performed under various cryogenic temperatures, gas flow rates and flow times. To measure the radon trapping efficiency, a radon calibration source was developed and characterized. In addition, the performance of the trap was compared with that of bronze wool using underground lab air and N 2 from a cylinder. The outline of the paper is as follows. the experimental apparatus is detailed in Section 2 . The activated charcoal radon assay and analysis methodology, as well as, the radon calibration source characterization are described in Section 3 . The background and efficiency of the charcoal trap, as well as a comparison of its performance with underground lab air and N 2 assays to that of bronze wool, are presented in Section 4 . In addition, the performance and sensitivity of our radon system with the addition of the charcoal trap was compared with the original system without the charcoal trap. The conclusion and discussion are provided in Section 5 . 2 Apparatus 2.1 Radon board At SNOLAB, there are two radon boards used for material screening: one is located in the underground lab, and the other is in the surface building (Figure 2 ). The underground board’s tube diameter is 3/8", while the surface board’s tube diameter is 1/2". Both boards follow the design described in Ref. [ 6 ] . The schematic of these two boards are shown in Figure 3 a. They each consisted of an emanation chamber, a U-shaped primary radon trap (Trap A), a concentration trap (Trap B), a detachable Lucas cell (LC) and a scroll pump capable of creating a vacuum of <5.0\times 10^{-3} mbar. The emanation chamber is used to place material samples for 222 Rn measurements. Trap A is filled with fine bronze wool to enhance radon trapping. The boards are equipped with a high-purity mass flow meter and three pressure transducers to monitor gas flow and pressures in both traps, as well as inlet pressure going into the vacuum pump. Figure 2: Picture of SNOLAB’s underground radon board Figure 3: Schematic view of a) a SNOLAB radon board b) portable activated charcoal trap c) calibration system apparatus and d) a cover gas system filled with N 2 The underground board was built in 1993 from 316L stainless steel and Swagelok vacuum fittings during the SNO construction and was refurbished in 2019. It is regularly leak checked using a He mass spectrometer for an acceptable leak rate of <1\times 10^{-7} mbar \cdot