Alignment and optical verification of DESHIMA 2.0 at ASTE

Arend Moerman, Kenichi Karatsu, Jochem J. A. Baselmans, Shahab O. Dabironezare, Shinji Fujita, Robert Huiting, Kotaro Kohno, Yuri Nishimura, Fenno Steenvoorde, Tatsuya Takekoshi, Yoichi Tamura, Akio Taniguchi, Stephen J. C. Yates, Bernhard R. Brandl, Akira Endo · 2025

Read Alignment and optical verification of DESHIMA 2.0 at ASTE by Arend Moerman, Kenichi Karatsu, Jochem J. A. Baselmans, Shahab O. Dabironezare, Shinji Fujita, Robert Huiting, Kotaro Kohno, Yuri Nishimura, Fenno Steenvoorde, Tatsuya Takekoshi, Yoichi Tamura, Akio Taniguchi, Stephen J. C. Yates, Bernhard R. Brandl, Akira Endo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-14478.txt.

Introduction

Arend Moerman and co-authors describe how they aligned and verified a wide-band spectrometer on a telescope in the Atacama, in work from 2025. The instrument, DESHIMA 2.0, observes across a broad microwave band. Its warm optics sit on a motor-driven hexapod that can tilt and shift them into exact position.

The key tool is a sky chopper with small apertures that couple the beam to the cold sky. By scanning the beam across the aperture and minimising the warm-cabin signal on the detectors, the team finds the best alignment. They characterised the procedure in the lab with a liquid nitrogen cold source, then applied it at the telescope. Aperture efficiency improved clearly over earlier reported values, confirming the method works on site.

Catalog record

CREATORArend Moerman, Kenichi Karatsu, Jochem J. A. Baselmans, Shahab O. Dabironezare, Shinji Fujita, Robert Huiting, Kotaro Kohno, Yuri Nishimura, Fenno Steenvoorde, Tatsuya Takekoshi, Yoichi Tamura, Akio Taniguchi, Stephen J. C. Yates, Bernhard R. Brandl, Akira Endo
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE57 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-14478

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Alignment and optical verification of DESHIMA 2.0 at ASTE Arend Moerman, Kenichi Karatsu, Jochem J. A. Baselmans, Shahab O. Dabironezare, Shinji Fujita, Robert Huiting, Kotaro Kohno, Yuri Nishimura, Fenno Steenvoorde, Tatsuya Takekoshi, Yoichi Tamura, Akio Taniguchi, Stephen J. C. Yates, Bernhard R. Brandl, Akira Endo Abstract We developed, characterized, and verified an alignment procedure for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200–400 GHz, at the ASTE telescope. To this end, we mounted the warm optics, consisting of a modified Dragonian dual reflector system, on a motor controlled hexapod. Crucial in the alignment procedure is our sky chopper, which allows fast beam switching. It has a small entrance and exit aperture coupling to (cold) sky, which creates a measurable signal with respect to the warm cabin environment. By scanning the instrument beam across the entrance aperture of the sky chopper using the hexapod, we found the hexapod configuration that produced the lowest signal on our detectors, implying the beam is coupled fully to cold sky and not the warm cabin. We first characterized the alignment procedure in the laboratory, where we used a vat containing liquid nitrogen as the cold source behind the sky chopper. Then, we applied the alignment procedure to DESHIMA 2.0 at ASTE. We found that the alignment procedure significantly improved the aperture efficiency compared to previously reported values of the aperture efficiency of DESHIMA at ASTE, which indicates the veracity of the alignment procedure. keywords alignment, optics, mechanical hexapod, submillimeter spectroscopy * Corresponding author, \linkable [email protected] 1 Introduction The Deep Spectroscopic High-redshift Mapper (DESHIMA) is an ultra wide-band (UWB) submillimeter (submm) integrated superconducting spectrometer (ISS) using MKIDs [ 1 ] . The primary design (DESHIMA 1.0 [ 2 ] ) has instantaneously covered 332–377 GHz by 49 frequency channels, and the demonstration instrument has succesfully seen first light in 2017 [ 3 ] at the 10-meter Atacama Submillimeter Telescope Experiment (ASTE) [ 4 ] telescope in Chile. DESHIMA 2.0 is a successor to DESHIMA 1.0 with the upgrades including an increase of the bandwidth (200–400 GHz), the number of frequency channels (347 channels), the optical efficiency, and the addition of a fast sky-position chopper for atmospheric subtraction, among others [ 5 ] . The science cases range from multi-line spectroscopy of dusty star-forming galaxies in order to calculate spectroscopic redshifts and study their physical conditions [ 6 ] , broad-band continuum observations of asymptotic giant branch stars, to galaxy cluster diagnostics through the Sunyaev-Zel’dovich effect [ 7 , 8 ] . The DESHIMA 2.0 design is based on a superconducting on-chip filterbank [ 9 , 10 ] , fed by a leaky-lens antenna [ 11 , 12 , 13 ] . The filterbank is connected to an NbTiN-Al hybrid MKID [ 14 ] array, which is read-out using frequency-domain multiplexing [ 15 ] . The integrated nature of the DESHIMA architecture and the multiplexed readout makes it inherently scalable and as such, it plays an important role in future integral field unit (IFU) designs [ 16 ] , such as the Terahertz Integral Field Unit with Universal Nanotechnology (TIFUUN) instrument which is currently in its early stages of development [ 17 ] . The cryostat housing DESHIMA 2.0 is an adiabatic demagnetization refrigerator (ADR), where it operates at a temperature of 120 mK. The submillimeter beam out of the vacuum window of DESHIMA can be misaligned from the design by as much as \sim 4 degrees [ 2 ] , which can lead to a significant degradation of the aperture efficiency when mounted on the ASTE telescope without sufficient correction [ 2 ] . Furthermore, because the cold optics are partially disassembled during transportation, there is no guarantee that the misalignment will be persistent from the laboratory to the telescope, requiring measurement of the misalignment in the telescope cabin. Fortunately, DESHIMA 2.0 employs a modified Dragonian dual reflector [ 18 ] at room temperature for magnification and coupling to the ASTE subreflector, and the positions of these mirrors can be adjusted to correct for potential misalignment. Such a correction for misalignment by one or more room-temperature optical components are common in mm/submm astronomy, though the exact methodology can vary depending on the system. A common method employs an optical laser to align the optics at the telescope. Examples include CONCERTO at APEX [ 19 , 20 ] and NIKA2 at IRAM [ 21 ] . However, this is an indirect method that assumes the submillimeter beam to be aligned to the laser ray, which is not the case for DESHIMA 2.0. The SOFIA instrument has used radiometric alignment by introducing an additional component that intercepts the beam [ 22 ] . An alternative approach is to measure the mechanical positions of the optical components by means of a Faro measurement arm and correct for any misalignment [ 23 ] , though the position of the cryogenic mirrors cannot be measured. Recently, Moerman et al. [ 24 ] have demonstrated a method for aligning the DESHIMA 2.0 instrument in the laboratory. They measured the complex (phase and amplitude) submm beam to extract misalignment information [ 25 , 26 ] and used this, in combination with a ray-tracing algorithm, to align the instrument using a modified Dragonian dual reflector and a mechanical hexapod. They argued that this method can correct for lateral shifts and tilt, but that a separate subreflector alignment should be performed to correct for the vertical shift, or defocus. However, applying this method at ASTE would require installing a coherent submm source and an XY-scanning stage in the small ASTE receiver cabin. Moreover, the presence of the aforementioned sky-position chopper significantly complicates the application of the alignment method of Moerman et al. [ 24 ] . In this paper we describe an alignment method that directly uses the instrument beam for alignment, without the need for quantification of misalignment using a visible light laser or a complex beam pattern measurement. The new method makes use of the temperature contrast between the room temperature entrance and exit apertures of the sky chopper and a cold background source, in combination with the modifed Dragonian dual reflector and mechanical hexapod also used by Moerman et al. [ 24 ] . The main advantage of the proposed method is the lack of need for elaborate measurement setups, making it simpler to execute than the procedure in Moerman et al. [ 24 ] . Instead, only a cold source, such as the atmosphere, is necessary. This makes the proposed method attractive for implementation at telescopes with limited receiver cabin space, such as the ASTE telescope. The method only has to be performed once after installation of the dual reflector, hexapod, and sky chopper. Also, the method can be executed fully remotely over an internet connection, eliminating the need to be physically present at the telescope site. This allows for remote checking of the alignment whenever it is desired. The paper is structured as follows. We start by briefly discussing the optical path of DESHIMA 2.0 at ASTE in Sect. 2.1 . Particular focus here will be given to the sky chopper. In Sect. 2.2 we discuss the general methodology behind the alignment method. Additionally, we discuss the

Read the complete text