Read Advancing MRI Reconstruction: A Systematic Review of Deep Learning and Compressed Sensing Integration by Mojtaba Safari, Zach Eidex, Chih-Wei Chang, Richard L.J. Qiu, Xiaofeng Yang (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-14158.txt.
Introduction
Mojtaba Safari and co-authors review how deep learning is speeding up MRI scans. MRI gives rich views inside the body without radiation. Its flaw is time: long scans discomfort patients and blur images when they move. Compressed sensing cuts scan time by sampling less data and rebuilding the image from the sparse set.
The review sorts deep learning methods that merge with that trick. Some learn the rebuild end to end, some unroll classic math steps into a network, and some learn across sites without pooling patient data. Gains in speed and sharpness are charted with the datasets used. The authors point to open needs and keep a public list of new work.
Catalog record
| CREATOR | Mojtaba Safari, Zach Eidex, Chih-Wei Chang, Richard L.J. Qiu, Xiaofeng Yang |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 74 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-14158
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Advancing MRI Reconstruction: A Systematic Review of Deep Learning and Compressed Sensing Integration Mojtaba Safari, Zach Eidex, Chih-Wei Chang, Richard L.J. Qiu, Xiaofeng Yang Abstract Magnetic resonance imaging (MRI) is a non-invasive imaging modality and provides comprehensive anatomical and functional insights into the human body. However, its long acquisition times can lead to patient discomfort, motion artifacts, and limiting real-time applications. To address these challenges, strategies such as parallel imaging have been applied, which utilize multiple receiver coils to speed up the data acquisition process. Additionally, compressed sensing (CS) is a method that facilitates image reconstruction from sparse data, significantly reducing image acquisition time by minimizing the amount of data collection needed. Recently, deep learning (DL) has emerged as a powerful tool for improving MRI reconstruction. It has been integrated with parallel imaging and CS principles to achieve faster and more accurate MRI reconstructions. This review comprehensively examines DL-based techniques for MRI reconstruction. We categorize and discuss various DL-based methods, including end-to-end approaches, unrolled optimization, and federated learning, highlighting their potential benefits. Our systematic review highlights significant contributions and underscores the potential of DL in MRI reconstruction. Additionally, we summarize key results and trends in DL-based MRI reconstruction, including quantitative metrics, the dataset, acceleration factors, and the progress of and research interest in DL techniques over time. Finally, we discuss potential future directions and the importance of DL-based MRI reconstruction in advancing medical imaging. To facilitate further research in this area, we provide a GitHub repository that includes up-to-date DL-based MRI reconstruction publications and public datasets- https://github.com/mosaf/Awesome-DL-based-CS-MRI . Journal: Biomedical Signal Processing and Control Abbreviations: bSSFP Balanced steady-state free precession CS compressed sensing DC Data consistency DL Deep learning DL-based MRI reconstruction Deep learning-based magnetic resonance imaging reconstruction DTI Diffusion-tensor imaging E2E End-to-end FFT Fast Fourier transform FID Fréchet inception distance FL Federated learning FLAIR Fluid-attenuated inversion recovery GRAPPA Generalized autocalibrating partially parallel acquisitions g-factor Geometry factor GRE Gradient echo MSE Mean absolute error MRA Magnetic resonance angiography MRI Magnetic resonance imaging MSE Mean square error NMSE Normalized mean square error ISTA Iterative shrinkage-thresholding algorithm PD Proton density PDFS Proton density fat-suppression RF Radio-frequency PSNR Peak signal-to-noise ratio R Acceleration rate RMSE Root mean square error RSS Root sum of squares T1c T1-weighted post-contrast MRI T1-MPRAGE T1-weighted magnetization-prepared rapid gradient-echo TV Total variation SENSE Sensitivity encoding SNR Signal-to-noise ratio SSIM Structural Similarity index SWI Susceptibility-weighted imaging 1 Introduction Magnetic resonance imaging (MRI) is a powerful diagnostic modality widely used for lesion detection and prognosis, radiation treatment planning, and post-treatment follow-up [ 1 , 2 ] . It offers high-resolution imaging of soft tissues, making it indispensable for numerous clinical applications. Nonetheless, the Lancet Oncology Commission recently emphasized a critical shortfall of MRI scanners and other imaging technologies in low-income and middle-income countries, contributing to an estimated 2.5 million annual deaths worldwide [ 3 ] . This shortfall is partly attributable to the high costs associated with installing, operating, and maintaining MRI systems. As of 2020, there were only seven MRI scanners per million people globally, underscoring the limited availability of this vital technology [ 4 ] . In addition to financial constraints, lengthy MRI acquisition times hinder the daily throughput of patients and exacerbate wait times [ 5 ] . Prolonged scan durations also increase the probability of voluntary and involuntary patient movements, resulting in motion artifacts that degrade image quality [ 6 ] . Such artifacts not only compromise diagnostic accuracy but also impose a substantial financial burden, with an estimated annual cost of $364,000 per scanner attributable to motion-related issues [ 7 ] . To address the dual challenges of high cost and extended scan times, advanced MRI reconstruction methods have been developed. In particular, compressed sensing (CS) MRI reconstruction leverages the sparsity of MRI images in certain transform domains to recover high-quality images from undersampled k -space data (see Section 1.1.2 ). Traditional CS approaches employ randomness in sampling patterns alongside sparsity-enforcing optimization techniques, thereby reducing the number of measurements needed and accelerating the imaging process. By maintaining diagnostic image quality while lowering scan times, CS-based strategies can alleviate financial constraints and increase patient throughput. In recent years, deep learning (DL) techniques have emerged as a promising complement or alternative to classical CS methods for MRI reconstruction. Unlike CS, which depends on explicit sparsity constraints, DL-based methods learn sophisticated mappings from undersampled to fully sampled images directly from training data (see Section 1.1.3 ). These methods can offer faster reconstruction times and exhibit robust performance in mitigating diverse artifacts and noise. While DL approaches do not explicitly enforce sparsity, their hierarchical structures can implicitly capture sparse representations. Consequently, integrating DL with CS principles can further enhance reconstruction quality and efficiency, thereby bridging the gap between traditional inverse problem formulations and modern data-driven strategies. Finally, modern MRI scanners largely rely on multi-coil acquisitions, which increase the signal-to-noise ratio (SNR) and enable accelerated imaging through parallel imaging (see Section 1.1.1 ) techniques. Although single-coil data commonly serve as a simplified test for newly proposed methods, most studies ultimately validate their techniques on both single-coil and multi-coil datasets to ensure real-world applicability and versatility. This dual-validation approach reflects the practicality and flexibility of current methods in accommodating various acquisition settings. 1.1 Conventional MRI acceleration techniques 1.1.1 Parallel imaging Parallel Imaging (PI) techniques, developed in the late 1990s, have greatly improved MRI by reducing scan times while preserving image quality [ 8 ] . PI speeds up image acquisition by using the spatial information from multiple receiver coils. These coils capture the same reduced amount of data, and the acceleration achieved results in undersampled aliased images unless advanced optimization techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) [ 9 ] or sensitivity encoding (SENSE) [ 10 ] are employed. Unlike traditional MRI, which uses a single coil, PI uses an array of coils, each with a unique spatial sensitivity profile (see Figure 1 ). Figure 1: (a) Images and (b) sensitivity maps, estimated by the ESPIRiT approach [ 11 ] , are illustrated for the first 15 receiver coils. Both the images and sensitivity maps are shown as magnitudes. The Root Sum of Squares (RSS) method combines images from multiple receiver coils by computing the square root of the sum of the squares of the individual coil images weighted by the corresponding conjugate sensitivity maps. This combined approach leverages the strengths of both the RSS method and sensitivity weighting to enhance the accuracy of the final reconstructed image. The underlying principle of PI is to use the different spatial sensitivities of multiple coils to reconstruct the missing k -space data. This process reduces the number of phase-encoding steps needed, thereby shortening the scan time. The reconstruction algorithms, specific to each PI technique, then use this coil sensitivity information to fill in the gaps in the acquired data [ 12 , 13 ] . There are two fundamental PI techniques as shown in Figure 2 . PI is a valuable technique in MRI but has its limitations. One primary limitation is noise amplification, quantified by the geometry factor (g-factor), which increases with higher acceleration factors. The g-factor reflects the noise penalty arising from under-sampling the k -space and the subsequent reconstruction