Read Synthetic CT image generation from CBCT: A Systematic Review by Alzahra Altalib, Scott McGregor, Chunhui Li, Alessandro Perelli (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-13972.txt.
Introduction
Alzahra Altalib, Scott McGregor, Chunhui Li, and Alessandro Perelli review deep learning methods that turn cone-beam scans into synthetic CT images, in a 2025 paper. Cone-beam CT is taken during cancer radiation treatment, but its quality is too low for planning doses. A synthetic CT built from it could let clinics adapt treatment to daily anatomy.
Following standard review rules, the team analysed thirty-five studies from 2014 to 2024. Common model types included convolutional networks, adversarial networks, transformers, and diffusion models. Standard error and similarity scores showed synthetic images close to gold-standard planning scans. Proton therapy studies are also covered. Problems that remain include mismatched fields of view and fitting the tools into clinic workflows. The authors call for more standard methods and shared benchmarks.
Catalog record
| CREATOR | Alzahra Altalib, Scott McGregor, Chunhui Li, Alessandro Perelli |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 67 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-13972
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Synthetic CT image generation from CBCT: A Systematic Review Alzahra Altalib, Scott McGregor, Chunhui Li, Alessandro Perelli Abstract The generation of synthetic CT (sCT) images from cone-beam CT (CBCT) data using deep learning methodologies represents a significant advancement in radiation oncology. This systematic review, following PRISMA guidelines and using the PICO model, comprehensively evaluates the literature from 2014 to 2024 on the generation of sCT images for radiation therapy planning in oncology. A total of 35 relevant studies were identified and analyzed, revealing the prevalence of deep learning approaches in the generation of sCT. This review comprehensively covers synthetic CT generation based on CBCT and proton-based studies. Some of the commonly employed architectures explored are convolutional neural networks (CNNs), generative adversarial networks (GANs), transformers, and diffusion models. Evaluation metrics including mean absolute error (MAE), root mean square error (RMSE), peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) consistently demonstrate the comparability of sCT images with gold-standard planning CTs (pCT), indicating their potential to improve treatment precision and patient outcomes. Challenges such as field-of-view (FOV) disparities and integration into clinical workflows are discussed, along with recommendations for future research and standardization efforts. In general, the findings underscore the promising role of sCT-based approaches in personalized treatment planning and adaptive radiation therapy, with potential implications for improved oncology treatment delivery and patient care. I Introduction Cone Beam Computed Tomography (CBCT) is a specific type of CT where a cone-shaped X-ray beam is used for the generation of 3D images [ 1 ] . Such images are high-resolution images generated using the unique anatomy of a patient. CBCT differs from conventional CT scanners, which often employ fan-shaped X-ray beams. CBCT functions by rotating the source and detector in a single trial on the patient’s body surface, allowing the generation of a volumetric dataset in a single scan. A CBCT system comprises several components, including an X-ray source, a flat panel detector, and a gantry for the rotation of the X-ray tube. During the scanning process, a cone-shaped beam penetrates the patient’s body,causing attenuation and dispersion of the beams. These attenuated and dispersed beams are transformed into images using reconstruction techniques, resulting in 2D and 3D images [ 2 , 3 ] . CBCT systems offer numerous advantages in radiotherapy compared to conventional systems. The high-resolution 3D image construction capability allows us the capture of finer anatomical details. Additionally, by collecting volumetric data in a single rotation, CBCT reduces acquisition time and X-ray exposure. This lower radiation dose compared to conventional CT makes it suitable for more frequent imaging and diagnosis [ 4 ] . Such benefits have enabled the application of CBCT in various fields, including diagnostic imaging, treatment planning, and intraoperative guidance. CBCT can precisely localize tumors and surrounding organs, enabling frequent target localization during treatment delivery. This capability allows medical personnel to capture 3D volumetric images before each treatment session, adjust the target volume position, and ensure accurate radiation delivery. Image-guided radiotherapy (IGRT) involves the use of CBCT which provides information about an individual’s anatomy prior to therapy. IGRT is the observation of the patient’s morphological differences between the time of the initial CT scan and subsequent therapy sessions (fractionally distributed), and it may be possible to alter therapy based on the detected variations [ 5 ] . One restriction to the practical application of CBCT in extracting patient information is because the visual appearance of CBCT scans is considered much worse than planned CT examinations with respect to contrast-to-noise ratios and the presence of imaging artifacts including streaking, which can be up to 50% more prevalent in CBCT scans [ 6 ] . X-ray scatter or internal motion are among the causes of streak abnormalities in abdominal imaging. This has sparked an increasing interest in developing strategies to improve the quality of CBCT scans to match that of CT [ 7 ] . The most well-established approach for producing synthetic CT (sCT) images with CT images is deformable image registration (DIR), which involves deforming the planned CT to fit the geometry of the CBCT [ 8 ] . The fundamental problem of DIR-based techniques is that the non-deformable alteration is not taken into account during the scans. For example, instances of lung compression and variation in air volumes and placements of the gastrointestinal (GI) are not taken into account [ 9 ] . Post-processing techniques can mitigate gross anatomical mismatches to some extent. But most DIR methods are too slow for real-time applications, which require computational performance equivalent to that of graphics processing units (GPUs) [ 10 ] . An alternative approach involves adjusting the scattering levels in the CBCT images. Over the past two decades, deep learning (DL) has emerged as a promising solution for healthcare image synthesis applications, including CBCT-to-CT conversion. Compared to traditional methods, data-driven DL approaches offer superior performance and adaptability to unexplored datasets. However, the need for large-scale data collection and curation remains a significant challenge [ 11 ] . DL has revolutionized medical imaging by learning complex representations from raw data, bypassing the reliance on hand-crafted features. This capability makes DL ideal for enhancing CBCT images in applications such as Adaptive Radiation Therapy (ART), where accurate imaging is critical to modifying treatment plans in real time. Traditional image processing methods struggle with the complexity of medical images, underscoring the need for advanced DL techniques that can automatically improve image quality and enhance the results of ART [ 12 ] . An alternative approach involves making adjustments to the levels of scattering in the CBCT images, which further contributes to improving image quality and reducing artifacts. In recent years, extensive research has focused on DL for image transformation, including hundreds of studies on CBCT-to-CT conversion. Several DL frameworks have been developed for this purpose, including U-Nets, paired pix2pix Generative Adversarial Networks (GANs) [ 13 , 14 ] and paired and unpaired cycle-consistent GANs (CycleGANs) [ 15 , 16 ] . Data-driven approaches such as these enable the translation of images between two imaging modalities. Unpaired CycleGANs are particularly advantageous in CBCT-to-CT synthesis because they do not require structurally connected paired data. This approach is especially relevant because simultaneous acquisitions of CBCT and CT scans are often impractical, and closely spaced scans reduce structural variations [ 17 ] . In the following section, we review the main DL architectures commonly applied to CBCT to CT image synthesis. I-A Deep Learning models for CBCT-to-CT Image Synthesis I-A 1 Convolutional Neural Networks (CNNs) they have been extensively applied in medical image analysis, particularly in tasks that require high precision, such as noise reduction and artifact removal. These techniques are particularly critical in ART, where accurate patient anatomy representation is necessary for real-time treatment adjustments [ 18 ] . Such an architecture allows the extraction of intricate details from within the medical images. Such details can be in the form of edges, gradients, and textures that can help refine the quality of CBCT images [ 12 ] . The capability of CNNs to capture both local and global image features makes them particularly useful in reconstructing CBCT scans, which are often plagued by noise and scatter [ 18 ] . U-Net architecture is widely regarded as one of