The Black Metal Tribometer: high-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles Journal: TRIBINT
Daniel Fochler a, Stefan Schwarz b, Lukas Kohlmann b, Malte Krack a · 2025
Read The Black Metal Tribometer: high-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles Journal: TRIBINT by Daniel Fochler a, Stefan Schwarz b, Lukas Kohlmann b, Malte Krack a (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-12838.txt.
Introduction
Daniel Fochler and co-authors present a new instrument, nicknamed the Black Metal Tribometer, for measuring friction where two surfaces rub. Their 2025 paper describes a rig built to record both how surfaces press in under load and the tiny back-and-forth slip cycles that waste energy in bolted joints. Better damping models for such joints need exactly this kind of clean data.
A key strength is that normal and sideways behavior are measured without taking the samples apart. Careful alignment and smooth motion let the team test flat-on-flat contact in the micro-slip range. Sample results show finely resolved slip cycles at sub-micrometer size under steady pressure, the raw material for checking joint models.
Catalog record
| CREATOR | Daniel Fochler a, Stefan Schwarz b, Lukas Kohlmann b, Malte Krack a |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 49 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-12838
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The Black Metal Tribometer: high-resolution measurement of normal load-indentation curves and partial slip hysteresis cycles Journal: TRIBINT Daniel Fochler a, Stefan Schwarz b, Lukas Kohlmann b, Malte Krack a Abstract A new instrument has been designed for measuring frictional hysteresis cycles and normal load-indentation curves. The primary purpose of the BMT is the validation of more predictive modeling approaches for damping in friction joints. An important original feature of the BMT is its ability to measure both normal and tangential contact behavior without having to separate the samples. Special attention was paid to alignment and smooth motion in order to permit testing nominally flat-on-flat contacts in the microslip regime. Examples are shown for finely resolved, undistorted hysteresis cycles with relative tangential displacement amplitudes in the sub-micrometer range at about 50 MPa nominal normal pressure, which is maintained well over the tangential load cycle. 1 Introduction To engineer mechanical systems against harmful vibrations, it is crucial to quantify their damping. The amount of damping determines, in particular, if resonances can be survived, how prone a system is to dynamic instabilities, and how quickly cyclic loads decay after a shock-type load. Damping can generally be due to inelastic processes within the material, interaction with fields of other physical origin (e. g. air flow), and dry frictional contact interactions at the interfaces. For most lightweight structures, dissipation within the material is negligible, and (dry) friction is the main cause of structural damping [ 1 ] . Some interfaces are designed for gross sliding and/or liftoff. This is the case, e. g., for friction dampers, like the under-platform dampers commonly used to mitigate vibrations of turbo-machinery blades [ 2 ] . Other interfaces do not have damping but load transmission, leak tightness or alignment as primary purpose. Common examples are contact interfaces at mechanical joints tightened by bolts or rivets. Those contacts never reach gross sliding / liftoff during operation (before failure). On the other hand, those contacts are not fully stuck either. To understand this, it is important to emphasize that real technical surfaces are not flat, but feature form deviations, waviness and roughness. Consequently, the real contact area may be a small fraction of the apparent (or nominal) contact area, even at high squeezing forces, and the contact pressure distribution is highly non-uniform, see e. g. [ 3 ] . Under vibratory loading, some parts of the contact area undergo microscopic relative motion, while the contact is still in a macroscopic stick phase. This regime is called partial slip , pre-sliding or microslip. It is useful to note that while the local relative displacements within a frictional clamping/joint may be <1~ µ \mathrm{m} , the maximum (absolute) vibration level of the jointed structure may be much larger (away from the clamping/joint). The effective damping ratio may reach some tenths of a percent for the critical low-frequency modes, and microslip is usually the main cause of dissipation if there are no dedicated means of vibration mitigation/dampers [ 1 ] . When the contacts undergo gross slip / complete liftoff, reasonable predictions of the nonlinear vibration behavior can be obtained, see e. g. [ 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 ] . In that regime, the surface irregularities (in particular waviness and roughness) play only a minor role, because their length scale is small compared to the relative contact displacements, and/or because they are worn away rapidly. Consequently, the associated finite compliance (contact stiffness) can often be neglected, and the contact model can be idealized to rigid unilateral behavior (Signorini conditions) in the normal contact direction and rigid Coulomb friction in the tangential contact plane, imposed between the nominal contact interfaces. The key parameter of such a contact model is the friction coefficient, which can be selected from experience or identified using relatively simple tribometers. In contrast, if the contacts undergo partial slip / partial liftoff, it is the present state knowledge that the vibration behavior is unpredictable [ 1 ] . Here, it is common practice to calibrate phenomenological models, such as the Dahl or the Bouc-Wen or the Iwan model, to vibration results of existing system dynamics test rigs [ 13 ] . By system dynamics test rig, we mean that a vibrating structure with friction joints is tested. The transfer to other / not-yet-fabricated systems is quite limited. Recent research efforts suggest that a sufficiently accurate description of the form [ 14 ] and/or the roughness [ 15 ] is crucial to develop more predictive modeling approaches for partial slip / partial liftoff [ 16 ] . An important prerequisite for developing more predictive partial slip models is a means to validate them. The aim to characterize nominally flat-on-flat contacts in the partial slip regime was an important motivation for developing the Black Metal Tribometer (BMT). Some test rigs involve application-oriented forms of joints and/or are to be categorized as system dynamics test rig, in the sense defined above, yet they are sufficiently instrumented to measure frictional force-displacement relations. Examples are the lap joint resonator in [ 17 , 18 , 19 ] , the under-platform damper test rigs in [ 20 , 21 , 22 , 23 ] , and the resonating beam subjected to friction and wear in [ 24 ] . The typical aim of such test rigs is the validation or identification of a whole-joint or system model. Other test rigs are better qualified to validate or identify local frictional contact models, where the intention is that the local model can be transferred to a wide range of applications. These test rigs are referred to as tribometers throughout this article. An important distinguishing feature of tribometers is the form of the apparent contact. In some cases, the apparent contact area is zero, as in the common pin-on-disk tribometer (point contact), see e. g. [ 25 ] . Here, the contact area becomes non-zero only under (in)elastic deformation and wear. A benefit of nominal point contacts is that no precise alignment is needed. The technical motivation of the present work is partial slip of conformal interfaces, i. e., contacts with non-zero nominal area. The transfer of models from point contacts to area contacts is difficult, if not impossible. Important reasons for this are the strong non-uniformity of the pressure distribution of nominal point contacts [ 26 ] , and their higher sensitivity to individual asperities [ 27 ] . For nominal point contacts [ 28 , 29 ] and line contacts [ 27 ] , tribometers have been built that are able to characterize frictional force-displacement relations in the partial slip regime. Others were developed with a focus on gross slip, and feature a rather poor resolution in the sub-micrometer range [ 30 , 31 ] . A thorough literature search was done to assess the present state of tribometry for nominally flat-on-flat contacts. This revealed that most tribometers are designed for gross or even reciprocating sliding. Their primary purpose is to characterize the relation between friction force and sliding distance and/or fretting damage in the form of wear or fatigue. For instance, the tribometer at the Imperial College [ 32 , 33 , 34 ] is