Read Quality Enhancement of Radiographic X-ray Images by Interpretable Mapping by Hongxu Yang, Najib Akram Maheen Aboobacker, Xiaomeng Dong, German Guillermo Vera Gonzalez, Lehel Mihály Ferenczi, Gopal Biligeri Avinash (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-12245.txt.
Introduction
Yang and five co-authors cleaned up X-ray images with an explainable method in this paper from twenty twenty-five. X-rays of the same body part can look wildly different across machines and patient positions. Technicians burn time adjusting brightness and contrast by hand. Black-box AI fixes exist, but clinicians cannot see why they act.
The new method mimics the manual workflow step by step. It corrects brightness and contrast globally and in local patches. Pixel maps show exactly what the model intends to change and why. On clinical data it reached strong fidelity scores against reference images. The authors pitch interpretability as the feature that earns clinical trust.
Catalog record
| CREATOR | Hongxu Yang, Najib Akram Maheen Aboobacker, Xiaomeng Dong, German Guillermo Vera Gonzalez, Lehel Mihály Ferenczi, Gopal Biligeri Avinash |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 11 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-12245
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Quality Enhancement of Radiographic X-ray Images by Interpretable Mapping Hongxu Yang, Najib Akram Maheen Aboobacker, Xiaomeng Dong, German Guillermo Vera Gonzalez, Lehel Mihály Ferenczi, Gopal Biligeri Avinash Abstract X-ray imaging is the most widely used medical imaging modality. However, in the common practice, inconsistency in the initial presentation of X-ray images is a common complaint by radiologists. Different patient positions, patient habitus and scanning protocols can lead to differences in image presentations, e.g., differences in brightness and contrast globally or regionally. To compensate for this, additional work will be executed by clinical experts to adjust the images to the desired presentation, which can be time-consuming. Existing deep-learning-based end-to-end solutions can automatically correct images with promising performances. Nevertheless, these methods are hard to be interpreted and difficult to be understood by clinical experts. In this manuscript, a novel interpretable mapping method by deep learning is proposed, which automatically enhances the image brightness and contrast globally and locally. Meanwhile, because the model is inspired by the workflow of the brightness and contrast manipulation, it can provide interpretable pixel maps for explaining the motivation of image enhancement. The experiment on the clinical datasets show the proposed method can provide consistent brightness and contrast correction on X-ray images with accuracy of 24.75 dB PSNR and 0.8431 SSIM. a]GE Healthcare, Netherlands b]GE Healthcare, USA c]GE Healthcare, Hungary keywords radiographic images, image quality enhancement, image consistency, deep learning † † authorinfo: Corresponding author: Hongxu Yang ([email protected]) 1 INTRODUCTION Figure 1: From raw image to left: global brightness and contrast adjustment for initial presentation after several iterations. From raw image to right: workflow for brightness and contrast enhancement at regional and global levels. Radiographic X-ray projection images are widely considered because they are easy to use and provide detailed regional structure information. Nevertheless, due to various scanning positions and anatomies, X-ray images may have different initial presentations, which need extra tuning and efforts by technologists and/or radiologists when reviewing them [ 1 ] . Therefore, to better visualize the X-ray images, additional adjustments of the brightness and contrast (BC) in regional (also known as tissue-equalization, TE) and global levels are needed, as an example shown in Figure 1. Traditionally, complex image processing chains are designed with multi-level operations to obtain the image appearance as shown in Figure 1, including segmentation, pixel intensity analysis, Look-up-table (LUT) constructions, etc. [ 2 , 3 ] Although this conventional image processing chain provides a good interpretable solution for radiologist and engineers, it may require dedicated system designs for different anatomies, scanning positions and patient sizes. Despite the complexity of the system, additional user tuning is practically inevitable due to the use of pre-defined configurations, which cannot be automatically and adaptively adjusted based on observed images [ 1 ] . To tackle the above challenges, we propose a deep-learning-driven automated image brightness&contrast enhancement/correction model, which is inspired by the multi-level image processing workflow [ 1 , 2 , 3 ] . 2 METHODS The method of automated X-ray image enhancement method is shown in Figure 2 (a), which consists of two key components: (1) pixel-wise parameter maps prediction of the input image, and (2) parameter maps transformation based on image processing inspired formulation mapping and LUTs. The input full resolution X-ray image is downsampled by a factor of 8 to fit the GPU memory, which is then processed by a ResUNet model [ 4 , 5 ] . Specifically, the considered model has 5-level resolutions, for each resolution of network, a simple residual convolution with three conv layers is applied [ 5 ] . For each convolution operation, number of features are fixed to 32, which is followed by InstanceNorm and LeakyReLU. The final output of the ResUNet are interpretable parameter maps of regional and global LUT functions for each pixel. Finally, the predicted maps are upsampled back to full resolution for formula remap projections, which is a pixel-level operation by using the input image as the input. With the obtain outputs, gray scale intensities are finally rescaled back to [0, 65535]. This method provides an interpretable parametrical map for each pixel to construct a pixel-wise LUT, as shown in Figure 2 (b), which is different to the conventional image processing methods where only image-level LUTs are provided [ 1 , 2 , 3 ] . Therefore, with aiding of deep learning, the pixel-wise LUTs can adaptively adjust the image presentation regionally and globally based on observed anatomies, scanning positions and patient sizes. Figure 2: (a) Interpretable maps prediction and enhanced image generation based on input image, predicted maps (a, b, wc and ww) and remap formula. (b) Regional LUT and global LUT for dynamic range of [0,65535]. To train the model of the ability to predict parameter maps, a specific loss function is designed based on LUTs parameters and remapping formula above. Specifically, the local adjustment is formulated by changing the pixel intensities for different dynamic range, as shown in top of Figure 2 (b), where the LUT is constructed by a piecewise monotonically increasing linear function. Therefore, the parameters of the function are pixel-wise slope a , and bias b . In contrast, the global adjustment is form by window-center ( wc ) and window-width ( ww ) of conventional brightness and contrast adjustment with sigmoid like function. The objective function is formulated in Eqn. 1 based on mean square error (MSE) at pixel level: \small Loss=MSE(img_{pred},img_{GT})+MSE(a_{pred},a_{gt})+MSE(b_{pred},b_{gt})+MSE(ww_{pred},ww_{gt})+MSE(wc_{pred},wc_{gt}) (1) During the training, data augmentations are randomly performed on-the-fly, which includes random rotation, mirror, shear, etc. The parameters are learned by the above loss function using Adam optimizer with learning rate of 1e-5. The training is terminated after converged on validation dataset with mini-batch size equals to 1. 3 RESULTS Figure 3: Top eight examples are selected from different models in Table 1, including the ground truth (GT). Bottom eight examples are enlarged ankle regions of corresponding model. The details of the bone structures are preserved by our method. Figure 4: Top: Outputs from the proposed method, which are adjusted regionally and globally for brightness and contrast. Bottom: Automated brightness and contrast adjustment globally only. To validate the proposed method, we used 429 X-ray images from clinical sites around the world. The dataset consists of different anatomy and scanning positions from daily clinical practice. We developed an in-house engineering tool to efficiently annotate the images with correct parameters, which provides consistent image look as the ground truth in Eqn. 1. The dataset is randomly partitioned to 356:30:43 for train/validation/test purposes. Specifically, due to different pre-processing of X-ray workflow and collimator size, X-ray image sizes are ranging from 1000 pixels to 4096 pixels for different anatomy. We compared image enhancement models of image-to-image translation by ResUNet at donwsample factor of 8, deep-learning-based brightness and contrast (DLBC) correction by directly predicting window-center and window-level (re-implemented based on proposal) [ 1 ] , 3DLUT by predicting intensity space weighted LUT [ 6 ] and supervised Zero-DCE, i.e. Sup-DCE [ 7 ] , as the references. Specifically, the 3DLUT consists of eight different LUT bases with dimension of 33 points [ 6 ] . As for the proposed method, downscale factor value of 4, 8, and 16 are considered for performance comparison. All the model trainings