Zero-shot Bias Correction: Efficient MR Image Inhomogeneity Reduction Without Any Data
Hongxu Yang, Edina Timko, Brice Fernandez · 2025
Read Zero-shot Bias Correction: Efficient MR Image Inhomogeneity Reduction Without Any Data by Hongxu Yang, Edina Timko, Brice Fernandez (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-12244.txt.
Introduction
Hongxu Yang, Edina Timko, and Brice Fernandez present a neural method that cleans up MRI scans without any training data, in this 2025 arXiv paper. Scanner images often carry a slow brightness drift, called a bias field, that blurs tissue contrast. Learning-based fixes usually need a prepared training set, which is costly to build.
Their design is a small convolutional network that adapts to each single scan on the spot, with no preset shape assumed for the drift. Correction proceeds as repeated rounds of evening-out, which keeps the process stable. Against the standard data-free method, N4, their approach scored better on both speed and accuracy across several test sets. The authors pitch it as a practical drop-in tool.
Catalog record
| CREATOR | Hongxu Yang, Edina Timko, Brice Fernandez |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 15 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-12244
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Zero-shot Bias Correction: Efficient MR Image Inhomogeneity Reduction Without Any Data Hongxu Yang, Edina Timko, Brice Fernandez Abstract In recent years, deep neural networks for image inhomogeneity reduction have shown promising results. However, current methods with (un)supervised solutions require preparing a training dataset, which is expensive and laborious for data collection. In this work, we demonstrate a novel zero-shot deep neural networks, which requires no data for pre-training and dedicated assumption of the bias field. The designed light-weight CNN enables an efficient zero-shot adaptation for bias-corrupted image correction. Our method provides a novel solution to mitigate the biased corrupted image as iterative homogeneity refinement, which therefore ensures the considered issue can be solved easier with stable convergence of zero-shot optimization. Extensive comparison on different datasets show that the proposed method performs better than current data-free N4 methods in both efficiency and accuracy. † † address: ⋆ STO-Artificial Intelligence & Machine Learning, GE HealthCare † IMG-MR-Applications & Workflow, GE HealthCare 1 Introduction Magnetic Resonance Imaging (MRI) provides detailed anatomy information of patient, which are essential for accurate and precise diagnosis and analysis. Nevertheless, MRI images are commonly degraded by several different artifacts, which hampers the information in the obtained data. Image inhomogeneity in MRI, which is commonly caused by bias field from imperfect scanner (such as phased-array coils) and magnetic filed distribution. With this scanning phenomenon in MRI, the signal intensity within the same anatomy would have a larger low-frequency variance across the obtained volume. Although this inhomogeneity might not be impacting the diagnoses by experienced clinicians, it would drastically degrade the subsequent image processing algorithms and methods, such as registration and segmentation in the fully automated image pipeline. Inhomogeneity removal in MRI has been studied during past decades, and the approaches are categorized as prospective and retrospective methods [ 1 ] . The prospective methods are commonly correcting the bias in the scanning step, which requires dedicated hardware and software design, and therefore economically expensive for medical device companies. In contrast, retrospective methods are processing the obtained images by various image processing techniques to reduce the inhomogeneity and bias in the data. The commonly considered correction methods can be classified into non-learning-based method and learning-based method. Specifically, the most popular non-learning-based method of bias correction is the nonparametric nonuniformity intensity normalization (N3) method [ 2 ] , and also its modification N4 [ 3 ] . Although these methods mostly achieved promising performances and widely accepted by communities of MR imaging, iteration computing on histogram and frequency correction has made these methods time consuming [ 4 ] . In addition, as shown in the literature, the N4 method tends to produce unrealistic results when the variance of the bias values are too large [ 5 ] . Recent years, (deep) learning-based correction have received remarkable attention in different artifacts reduction application. Supervised deep learning methods were developed for bias-free MRI generation with great success [ 6 , 7 ] . However, as known in the community, supervised learning methods are suffering lack of large amount of training images with ground truth. To tackle this limitation, unsupervised inhomogeneity correction methods with deep learning (DL) strategies were proposed, such as implicitly trained CNN [ 8 ] and histogram-based entropy correction method [ 4 ] . The aforementioned methods achieved comparable performances w.r.t. commonly applied N4 algorithm while reducing the annotation efforts of ground truth generation. Nevertheless, there are still several considerations about these methods. First, the implicitly trained CNN requires proper bias field simulation of the images, which is highly correlated to devices and anatomies. Therefore, dedicated research and training data preparation is inevitable. Second, to train a model that can be generalized to different situation, laborious data collection is needed and can be expensive for data preparations. Third, the network trained on such dataset suffers performance drop if the testing datasets are derived from different data distributions. All the above concerns motivated us to study the data-free method. Figure 1: Top: The light-weight zero-shot inhomogeneity correction model. The input 3D volumetric data is processed by feature extraction blocks to generate parametric maps for iterative homogeneity refinement and image prior loss. DSC: Depthwise Separable Convolutions. The proposed model has around 3k trainable parameters. Bottom: Iterative inhomogeneity correction with the predicted \alpha map per pixel. This paper presents a zero-shot inhomogeneity correction method based on deep learning. The method, as will be explained in the later section, composites two functions of homogeneity refinement and image prior constraint modules. Our solution is able to correct the bias corrupted images without any training data, by simply performing few steps of iteration at testing time with light-weight Convolutional Neural Network (CNN). The novel zero-shot method has three major contributions. First, common data-free methods requires solving an optimization problem at inference time. Standard CNN with huge number of parameter count would lead to large memory cost in hardware, e.g. GPU RAM and long processing time. In this work, we utilize a simple CNN architecture with only around 3k parameters, therefore the computational cost is drastically reduced within seconds. Second, our proposal provides a solution of bias field correction by iterative inhomogeneity refinement, therefore the considered problem is easier to be solved for zero-shot situation. Third, the extensive validation on public brain datasets and private pelvis datasets show the presented zero-shot method is comparable or even better than N4 method in both efficiency and accuracy performances. 2 Method The proposed zero-shot inhomogeneity correction method is depicted in Fig. 1 . The considered CNN has an efficient light encoder for feature extraction and two different pixel-to-pixel mapping modules for homogeneity correction and image prior loss. With designed regional and global loss functions, our zero-shot bias correction method is able to perform online optimization with efficient execution and high performance of bias field correction. 2.1 Methodology The bias corruption of MRI images is formulated by multiplying a bias field with some additive noise: Y=XB+n (1) where Y is the observed corrupted image, X is the bias-free MRI image, B is the bias field, and n is the additive noise. Common practice of bias correction with DL is to train a model to estimate B from the training data with certain distribution. In our solution, we choose an alternative approach that decomposes the above problem as homogeneity refinement with image prior constraint. Specifically, as observed in MRI images with strong bias artifacts, the resulted images are encountered similar situation of low-light nature image [ 9 ] , where intensities from the same region are having large variances due to imperfect detector and over/under-exposure of the information. Practically, the inhomogeneities of the dark and bright region can be iterative corrected by the function: HC(x,y,z)=I(x,y,z)+\alpha I(x,y,z)(1-I(x,y,z)) (2) where HC is the homogeneity corrected output of position (x,y,z) with intensity I and a learned parameter \alpha per data point. With high-order estimation of the HC, the pixel-based regional corruption can be adaptive refined, which is specifically defined as (without considering voxel position) HC^{n}=HC^{n-1}+\alpha HC^{n-1}(1-HC^{n-1}) (3) where parameter n is the number of iteration, which controls the strength of the homogeneity correction and was chosen to be 4 in the paper to trade-off accuracy and computation cost [ 9 ] . The above correction would