Finding Reproducible and Prognostic Radiomic Features in Variable Slice Thickness Contrast Enhanced CT of Colorectal Liver Metastases
\name Jacob J. Peoples https://orcid.org/0000-0003-0191-7446 \email [email protected], \name Mohammad Hamghalam https://orcid.org/0000-0003-2543-0712, \name Imani James, \name Maida Wasim, \name Natalie Gangai https://orcid.org/0000-0003-0603-7165, \name Hyunseon Christine Kang https://orcid. · 2025
Read Finding Reproducible and Prognostic Radiomic Features in Variable Slice Thickness Contrast Enhanced CT of Colorectal Liver Metastases by \name Jacob J. Peoples https://orcid.org/0000-0003-0191-7446 \email [email protected], \name Mohammad Hamghalam https://orcid.org/0000-0003-2543-0712, \name Imani James, \name Maida Wasim, \name Natalie Gangai https://orcid.org/0000-0003-0603-7165, \name Hyunseon Christine Kang https://orcid. (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-11221.txt.
Introduction
Jacob Peoples and co-authors tested which scan traits of liver tumors stay stable and foretell survival in a 2025 paper. The traits, called radiomic features, are numbers pulled from CT scans of cancer that spread to the liver from the colon. Scans rebuilt at unlike slice widths can shift those numbers, which puts their clinic use at risk.
They used scans from eighty one patients at two United States centers to grade which traits hold steady across widths. A second public set of one hundred ninety seven scans let them test which traits track survival after surgery. Which setting won swung by trait and by zone, tumor or plain liver. The best survival model came from one set of settings, before grading for stability.
Catalog record
| CREATOR | \name Jacob J. Peoples https://orcid.org/0000-0003-0191-7446 \email [email protected], \name Mohammad Hamghalam https://orcid.org/0000-0003-2543-0712, \name Imani James, \name Maida Wasim, \name Natalie Gangai https://orcid.org/0000-0003-0603-7165, \name Hyunseon Christine Kang https://orcid. |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 57 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-11221
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Finding Reproducible and Prognostic Radiomic Features in Variable Slice Thickness Contrast Enhanced CT of Colorectal Liver Metastases \name Jacob J. Peoples https://orcid.org/0000-0003-0191-7446 \email [email protected], \name Mohammad Hamghalam https://orcid.org/0000-0003-2543-0712, \name Imani James, \name Maida Wasim, \name Natalie Gangai https://orcid.org/0000-0003-0603-7165, \name Hyunseon Christine Kang https://orcid.org/0000-0001-5313-3526, \name X. John Rong https://orcid.org/0000-0002-1169-5042, \name Yun Shin Chun https://orcid.org/0000-0003-1384-8927, \name Richard K. G. Do https://orcid.org/0000-0002-6554-0310, \name Amber L. Simpson https://orcid.org/0000-0002-4387-8417 Abstract Establishing the reproducibility of radiomic signatures is a critical step in the path to clinical adoption of quantitative imaging biomarkers; however, radiomic signatures must also be meaningfully related to an outcome of clinical importance to be of value for personalized medicine. In this study, we analyze both the reproducibility and prognostic value of radiomic features extracted from the liver parenchyma and largest liver metastases in contrast enhanced CT scans of patients with colorectal liver metastases (CRLM). A prospective cohort of 81 patients from two major US cancer centers was used to establish the reproducibility of radiomic features extracted from images reconstructed with different slice thicknesses. A publicly available, single-center cohort of 197 preoperative scans from patients who underwent hepatic resection for treatment of CRLM was used to evaluate the prognostic value of features and models to predict overall survival. A standard set of 93 features was extracted from all images, with a set of eight different extractor settings. The feature extraction settings producing the most reproducible, as well as the most prognostically discriminative feature values were highly dependent on both the region of interest and the specific feature in question. While the best overall predictive model was produced using features extracted with a particular setting, without accounting for reproducibility, (C-index = 0.630 (0.603–0.649)) an equivalent-performing model (C-index = 0.629 (0.605–0.645)) was produced by pooling features from all extraction settings, and thresholding features with low reproducibility ( CCC ≥ 0.85 \mathrm{CCC}\geq 0.85 ), prior to feature selection. Our findings support a data-driven approach to feature extraction and selection, preferring the inclusion of many features, and narrowing feature selection based on reproducibility when relevant data is available. Keywords: Radiomics, Texture Analysis, Reproducibility, Colorectal Liver Metastases, Quantitative Imaging Biomarkers, Computed Tomography, Prospective Studies, Reproducible Features 1 Introduction Radiomic analysis as a field is predicated on the idea that radiological imaging contains meaningful biological information contained in the patterns of intensity values within regions of interest, which could contribute to a better understanding of patient health ( Gillies et al., 2016 ) . The typical approach in radiomic studies is to extract a large number of pre-defined quantitative imaging features from a region of interest, and then use machine learning methods to reduce the dimensionality of the feature set and build models of a biological correlate or a medical outcome of interest ( Horvat et al., 2022 ) . The promise of radiomics to develop quantitative imaging biomarkers is of broad interest because it poses a non-invasive means to characterize patient disease using routine clinical imaging. However, to be clinically deployed, radiomic models must be widely validated, and their robustness to variable imaging settings well-established. In the present study, we are focused on contrast-enhanced abdominal CT ( CT ) of the liver for patients with CRLM ( CRLM ). These patients have an overall poor prognosis, which could potentially be improved by prognostic radiomic signatures that could better target patients for surgery or chemotherapy. In patients with liver metastases, radiomic models derived from contrast-enhanced CT have shown substantial prognostic capability in both survival modeling and prediction of chemotherapy response ( Fiz et al., 2020 ) . Furthermore, although most studies focus on radiomic features extracted from the metastases themselves, studies of CRLM have shown that features from the liver parenchyma also contain important information when predicting hepatic disease-free survival or overall survival after hepatic resection ( Simpson et al., 2017 ) , or progression-free survival after radiotherapy ( Hu et al., 2022b ) . With these applications in mind, in this study we are seeking to gain a better understanding of the robustness of radiomic models in contrast-enhanced CT of CRLM . One way to study the robustness of radiomic models is to study the reproducibility of the model inputs—that is, to understand how consistent the radiomic features are under real-world variations that occur in image acquisition and reconstruction. Treating the radiomic features as measurements drawn from radiological images, the reproducibility of the features can be studied from a metrological perspective ( Raunig et al., 2014 ) , using statistical measures such as the CCC ( CCC ). Understanding the reproducibility of radiomic features, however, is difficult given the many factors affecting the results. Restricting the discussion to CT , scans are acquired from different medical centers, using different scanners, with different imaging acquisition parameters and protocols, after which the images are reconstructed with different algorithms, different resolution parameters, and different kernels, all of which have been shown to affect feature reproducibility ( Zhao, 2021 ) . Once the images are in hand, feature extraction itself is not without concerns regarding reproducibility; while standardization efforts such as the IBSI ( IBSI ) ( Zwanenburg et al., 2020 ) have been instrumental in creating a common nomenclature and a standard set of well-defined features, they do not provide a final answer in how to set the many configurable parameters which can affect the final feature values computed by common software such as pyradiomics ( van Griethuysen et al., 2017 ) . In this study, we are considering feature reproducibility particularly when the slice thickness used to reconstruct the CT scans is varied. When comparing features extracted from CT images with thinner or thicker slices, studies have found that features from thinner images are more reproducible across variations in segmentation ( Hu et al., 2022a ) , or across repeat imaging ( Zhao et al., 2016 ) , and may also produce more accurate models ( He et al., 2016 ; Li et al., 2018 ; Xu et al., 2022 ) . In direct comparisons, many features had poor reproducibility when comparing features from images with different slice thicknesses in a variety of phantom studies ( Zhao et al., 2014 ; Ger et al., 2018 ; Berenguer et al., 2018 ; Kim et al., 2019 ; Varghese et al., 2019 ; Ligero et al., 2021 ; Ibrahim et al., 2022 ) . Prospective studies producing multiple reconstructions for each patient have reproduced this result on patient images for lung cancer ( Lu et al., 2016 ; Park et al., 2019 ; Erdal et al., 2020 ; Yang et al., 2021 ; Emaminejad et al., 2021 ) , and liver metastases ( Meyer et al., 2019 ) . Poor feature reproducibility with respect to slice thickness is concerning because many real-world retrospective or multi-site data sets include images with a range of different slice thicknesses due to variations in local protocols ( Ger et al., 2018 ) . Although image interpolation to a common, isotropic voxel size is considered a best practice for preprocessing during feature extraction ( Zwanenburg et al., 2020 ) in order to ensure the image features are comparable between images with different voxel sizes, the optimal choice of resolution and resampling algorithm is undecided. Furthermore, resampling to a