Temporal characterization of femtosecond electron pulses inside ultrafast scanning electron microscope

Kamila Moriová, Petr Koutenský, Marius-Constantin Chirita-Mihaila, Martin Kozák · 2025

Read Temporal characterization of femtosecond electron pulses inside ultrafast scanning electron microscope by Kamila Moriová, Petr Koutenský, Marius-Constantin Chirita-Mihaila, Martin Kozák (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-10250.txt.

Introduction

Kamila Moriová, Petr Koutenský, Marius-Constantin Chirita-Mihaila, and Martin Kozák clock electron pulses inside an ultrafast electron microscope using only light. Knowing a pulse's duration at the exact spot where it meets the sample is essential and hard. Their all-optical method lets electrons interact with the ponderomotive push of an optical standing wave. The measurement happens in situ, across electron energies from one to thirty kiloelectron volts.

Single-photon photoemission from a Schottky tip, driven by ultraviolet femtosecond pulses, launches the electrons. Durations ran from half a picosecond at the top energy to under three picoseconds at lower energy, once Coulomb effects were negligible. Halving the photon energy halved the emitted electrons' energy spread and shortened pulses further. The technique gives ultrafast microscopy a stopwatch at the interaction point.

Catalog record

CREATORKamila Moriová, Petr Koutenský, Marius-Constantin Chirita-Mihaila, Martin Kozák
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-10250

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Temporal characterization of femtosecond electron pulses inside ultrafast scanning electron microscope Kamila Moriová, Petr Koutenský, Marius-Constantin Chirita-Mihaila, Martin Kozák Abstract In this work, we present the implementation of all-optical method for directly measuring electron pulse duration in an ultrafast scanning electron microscope. Our approach is based on the interaction of electrons with the ponderomotive potential of an optical standing wave and provides a precise in situ technique to characterize femtosecond electron pulses at the interaction region across a wide range of electron energies (1–30 keV). By using single-photon photoemission of electrons by ultraviolet femtosecond laser pulses from a Schottky emitter we achieve electron pulse durations ranging from 0.5 ps at 30 keV to 2.7 ps at 5.5 keV under optimal conditions where Coulomb interactions are negligible. Additionally, we demonstrate that reducing the photon energy of the femtosecond pulses used for photoemission from 4.8 eV (257.5 nm) to 2.4 eV (515 nm) decreases the initial energy spread of emitted electrons, leading to significantly shorter pulse durations, particularly at lower electron energies. I Introduction In recent years, ultrafast electron microscopy (UEM) has emerged as a powerful method for investigating the dynamics of fundamental processes with high temporal and spatial resolution Flannigan and Zewail 2012 . Four-dimensional visualization of dynamic processes can be achieved through laser pump and electron probe experiments, where an optical pulse excites the sample, and an electron pulse probes the transient state of the material at precise time delay with respect to the arrival of the optical pump. Unlike traditional optical methods of pump-probe microscopy, which are spatially averaged over the probe spot size and constrained by the wavelength of light (Abbe’s limit), UEM leverages the shorter wavelength of electron probes to offer unique insights at the atomic scale with significantly better spatial resolution. In the past, time-resolved imaging with pulsed electron beams has enabled studies of phenomena such as the dynamics of phase transitions Baum, Yang, and Zewail 2007 ; Gedik et al. 2007 ; Danz, Domröse, and Ropers 2021 ; Van Der Veen et al. 2013 , the kinetics of fast reactions in nanomaterials Sinha et al. 2019 ; Ruan et al. 2007 , magnetization dynamics Rubiano da Silva et al. 2018 ; Berruto et al. 2018 or the structural dynamics of molecules Hensley, Yang, and Centurion 2012 ; Ihee et al. 2001 . There is also growing interest in using this technique to study the optical response of nanophotonic structures Polman, Kociak, and García de Abajo 2019 ; Barwick, Flannigan, and Zewail 2009 ; Piazza et al. 2015 or ultrafast charge dynamics at semiconductor interfaces for optoelectronic applications Kosar and Dani 2024 ; Cho, Hwang, and Zewail 2014 . Additionally, recent advancements in UEM have expanded the focus from material studies to the investigation of electron-light interactions, enabling the manipulation of electron wavefunctions Feist et al. 2015 ; Tsarev, Thurner, and Baum 2023 ; Shiloh, Chlouba, and Hommelhoff 2022 ; Talebi 2020 . These developments have led to applications such as the generation of attosecond electron pulses Priebe et al. 2017 ; Kealhofer et al. 2016 ; Kozák, Schönenberger, and Hommelhoff 2018 ; Ryabov et al. 2020 ; Morimoto and Baum 2018a ; Morimoto and Baum 2018b , electron acceleration Chlouba et al. 2023 , and the formation of electron vortex beams Vanacore et al. 2019 ; Kozák 2021 . To achieve the highest time resolution in UEM, it is essential to generate short electron pulses and accurately determine their durations, as the temporal resolution of pump-probe experiments is given by the electron pulse duration rather than the detector’s acquisition speed. Currently, two techniques are used to generate pulsed electron beams in UEM Zhang et al. 2019 : laser-driven photoemission sources and electron beam blanking. These techniques can achieve electron pulse durations on the femtosecond and picosecond scales, respectively Moerland et al. 2016 . Furthermore, a design for a beam blanker incorporating a photoconductive switch has been proposed, which could enable electron pulse widths as short as 100 fs Weppelman et al. 2018 ; Weppelman et al. 2019 . However, maintaining the short duration of electron pulses from source to sample is challenging due to the velocity spread of electrons and the action of Coulomb forces. Electron-electron repulsion by electrostatic forces can be mitigated by using less than one electron per pulse on average. Pulse broadening due to dispersive propagation of electrons with finite energy-momentum spread is unavoidable and leads to prolongation of the electron pulse duration to several hundreds of femtoseconds Baum 2013 ; Aidelsburger et al. 2010 . Only few techniques have been developed to directly measure the sub-picosecond durations of low-density electron pulses. One approach is based on electron-light cross-correlation utilizing the inelastic scattering of electrons induced by the interaction with optical near field excited at the surface of a nanostructure Barwick, Flannigan, and Zewail 2009 ; Park, Lin, and Zewail 2010 ; Park, Kwon, and Zewail 2012 ; Feist et al. 2017 ; Plemmons et al. 2014 ; Kozák et al. 2018a ; Kirchner et al. 2014 . However, this technique is limited by the requirement for the UEM or electron gun to be equipped with a high-resolution spectrometer capable of spectrally filtering inelastically scattered electrons. Additionally, experiment must be designed for a specific electron energy, as the interaction between the electrons and the laser field is energy-dependent. Alternatively, the electron pulse can be characterized by streaking in a THz field generated by high-density photoemitted electrons from a transmission electron microscopy (TEM) grid Plemmons and Flannigan 2017 or directly by the THz waveform Kealhofer et al. 2016 but this method has limited time resolution. Figure 1: (a) Layout of the experimental setup. Electron pulses are photoemitted from a Schottky nanotip using focused ultraviolet or visible laser pulses (the fourth or second harmonic of a femtosecond laser with ytterbium-doped gain medium with a central wavelength of 1030 nm). The electron pulses interact with an optical grating formed by two overlapping laser beams, resulting in scattering by the ponderomotive force. Precise timing of the electron and laser pulses is achieved using two independent delay lines, enabling control over their relative arrival times. (b) The schematics depicts the process of elastic ponderomotive scattering, where electrons interact with a standing light wave in a classical interaction regime. (c) Images of scattered electron beam captured on the detector at various laser pulse–electron pulse delays, with optimal overlap defined as \Delta\tau_{2}=0 ps. The images were acquired for 15 keV electron pulses under conditions of negligible Coulomb repulsion, using a 64 \mu m aperture. The data represent an integration over 25,000 pulses, superposed across five measurements. The techniques described above rely on high-resolution electron spectrometers that are currently optimized for high-energy electrons, as commonly used in ultrafast transmission electron microscopes (UTEMs). In contrast, scanning electron microscopes (SEMs) operate at much lower electron energies (usually 1–30 keV), which are designed for imaging of sample surface using secondary or back-scattered electrons. The low-energy electrons typically do not propagate through the sample in SEM and thus there is no transmitted electron beam, for which the inelastic interaction with light can be characterized. As a result, implementing electron energy loss spectroscopy (EELS)-like techniques in the low-energy electron regime is not yet widely adopted.

Read the complete text