Scan-Adaptive MRI Undersampling Using Neighbor-based Optimization (SUNO)

Siddhant Gautam, Angqi Li, Nicole Seiberlich, Jeffrey A. Fessler, Saiprasad Ravishankar · 2025

Read Scan-Adaptive MRI Undersampling Using Neighbor-based Optimization (SUNO) by Siddhant Gautam, Angqi Li, Nicole Seiberlich, Jeffrey A. Fessler, Saiprasad Ravishankar (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-09799.txt.

Introduction

Siddhant Gautam and co-authors tailor MRI sampling to each scan in a 2025 paper. Fast MRI takes just part of the raw data to cut scan time and motion blur. Set sampling grids serve the mean patient, yet miss the traits of each scan.

Their SUNO frame learns a sampling grid per scan type, paired with a rebuild model. At test time, early low tone data pick the best grid from learned kin. Joint learning swaps steps between grid choice and model tuning. Knee scan tests from a public set check the frame. Per scan grids should keep fine detail that set grids lose.

Catalog record

CREATORSiddhant Gautam, Angqi Li, Nicole Seiberlich, Jeffrey A. Fessler, Saiprasad Ravishankar
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE43 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-09799

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Scan-Adaptive MRI Undersampling Using Neighbor-based Optimization (SUNO) Siddhant Gautam, Angqi Li, Nicole Seiberlich, Jeffrey A. Fessler, Saiprasad Ravishankar Abstract Accelerated MRI involves collecting partial k k -space measurements to reduce acquisition time, patient discomfort, and motion artifacts, and typically uses regular undersampling patterns or hand-designed schemes. Recent works have studied population-adaptive sampling patterns that are learned from a group of patients (or scans) based on population-specific metrics. However, such a general sampling pattern can be sub-optimal for any specific scan since it may lack scan or slice adaptive details. To overcome this issue, we propose a framework for jointly learning scan-adaptive Cartesian undersampling patterns and a corresponding reconstruction model from a training set. We use an alternating algorithm for learning the sampling patterns and reconstruction model where we use an iterative coordinate descent (ICD) based offline optimization of scan-adaptive k k -space sampling patterns for each example in the training set. A nearest neighbor search is then used to select the scan-adaptive sampling pattern at test time from initially acquired low-frequency k k -space information. We applied the proposed framework (dubbed SUNO) to the fastMRI multi-coil knee and brain datasets, demonstrating improved performance over currently used undersampling patterns at both 4 × 4\times and 8 × 8\times acceleration factors in terms of both visual quality and quantitative metrics. The code for the proposed framework is available at https://github.com/sidgautam95/adaptive-sampling-mri-suno . I Introduction Magnetic Resonance Imaging (MRI) is a widely used non-invasive biomedical imaging technology that allows visualization of both anatomical structures and physiological functions. Some of its benefits include a lack of ionizing radiation and excellent soft-tissue contrast. MRI scanners sequentially collect measurements in the time (or spatial frequency) domain (known as k -space), from which an image is reconstructed. The scanner must sample numerous k -space points in order to estimate an image with a clinically appropriate spatial resolution, which causes the acquisition process to be slow and expensive. Accelerating MRI scans reduces acquisition time, reduces patient discomfort, increases scaling throughput, and reduces motion artifacts. Such acceleration often requires choosing an appropriate undersampling pattern or trajectory along with a reconstruction model that enables accurate recovery from reduced measurements. Some of the earliest approaches for accelerating MR imaging included pulse sequence and k -space trajectory design [ 1 , 2 , 3 ] and parallel imaging [ 4 , 5 , 6 ] , which exploits the spatial information available when using an array of receiver coils. Parallel imaging offers hardware-based acceleration but often suffers from increased noise and imperfect artifact correction at higher undersampling rates. It is limited to smaller acceleration factors because of imperfect artifact correction and higher noise at higher acceleration rates. Compressed sensing (CS) [ 7 , 8 ] has been widely used to enable the reconstruction of MR images from a reduced set of measurements. Traditional MRI follows the Nyquist-Shannon theorem, requiring dense sampling in k -space. However, according to CS theory, the k -space sampling can be done at sub-Nyquist rates and the image can be reconstructed using prior knowledge of sparsity in some transform domain [ 9 , 8 , 10 , 11 ] when the sampling operator and sparsity basis are sufficiently incoherent. Some of the widely used undersampling patterns in CS-MRI include variable density [ 12 ] , Poisson-disc [ 13 ] , combined variable density and Poisson disc [ 14 ] , and equispaced Cartesian with skipped lines [ 15 ] . Recently, approaches using learned image models for reconstruction have also been explored. These methods include techniques such as synthesis dictionary learning [ 16 , 17 , 18 , 19 ] and transform learning [ 20 , 21 ] . With the advent of deep learning, convolutional neural networks (CNNs) have achieved tremendous success in reconstructing MR images from undersampled measurements. Some of these approaches have used U-Net architectures [ 22 ] by training them in a supervised manner to remove artifacts in aliased images [ 23 ] . Similarly, variational networks have been used to solve the image reconstruction problem for accelerated multi-coil MRI by combining neural networks with the MR forward model [ 24 , 25 ] . Other works in deep learning-based MRI reconstruction include ADMM-Net [ 26 ] and GANs [ 27 ] . Recently, MoDL [ 28 ] has become quite popular in solving the MRI reconstruction problem in which the MRI forward model is used within a data consistency term, and a CNN reconstructor is used as a denoiser to regularize the reconstruction. One of the first works to optimize MRI undersampling patterns used training k -space data and reconstruction error as the training loss to optimize a single pattern over training scans [ 29 ] . Subsequent work on sampling optimization designed adaptive sampling patterns using the power spectra of the reference k -space data [ 30 , 31 ] or the energy preserving sampling method [ 32 ] . Statistical experiment design techniques for MRI sampling prediction were proposed that used the Cramer-Rao lower bound [ 33 , 34 ] . Later, the greedy algorithm and its variations were used to learn a single population-adaptive sampling pattern over a training set of images with a specific choice of reconstruction method [ 35 , 36 ] . Since these approaches learn the undersampling pattern using greedy algorithms over a large number of images, the computational cost involved is high and it scales quadratically with the number of lines in the mask. To avoid this, a stochastic version of the greedy mask learning algorithm was proposed that resolved the scaling issues of the previous greedy approaches [ 37 ] . Recently, deep learning approaches were proposed that jointly learn a sampling pattern and a corresponding trained reconstruction network [ 38 , 39 , 40 , 41 , 42 , 43 , 44 ] . LOUPE [ 38 ] and its multi-coil extension [ 39 ] determines the probability of sampling each pixel or row/column in the k -space domain. Its underlying parameters are learned jointly with those of the reconstructor (U-Net). Similarly, J-MoDL [ 40 ] jointly learns an MoDL reconstruction network and a sampling pattern whose parameters are optimized separately along the row and column directions. MNet [ 44 ] also explored jointly training a reconstruction network and a CNN-based sampler to predict the undersampling pattern directly from low-frequency k -space information. Bias-accelerated subset selection (BASS) [ 42 , 43 ] , a subset selection method for learning sampling patterns, was proposed for parallel MRI applications, which gives a fast way to learn sampling patterns. AutoSamp [ 45 ] is one of the recent deep learning methods proposed for joint optimization of sampling patterns and reconstruction for 3D MRI that uses variational information maximization. Sequential decision processes have also been applied to undersampling prediction where they sequentially learn MRI sampling patterns using reinforcement learning. In these problems, the sampling optimization is formulated as a partially observable Markov decision process (POMDP) [ 46 , 47 ] . Subsequent works used a reconstruction model trained simultaneously with a sampler that predicts sampling patterns sequentially [ 48 ] . These works can be divided into the ones predicting Cartesian undersampling patterns [ 38 , 48 ,

Read the complete text