The ultra-low material budget GEM-based TPC for tracking with VMM3a readout
X. Zhao · 2025
Read The ultra-low material budget GEM-based TPC for tracking with VMM3a readout by X. Zhao (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-09587.txt.
Introduction
A large team reports tests of a very light particle tracker for use at CERN, in a paper from 2025. The device uses gas based sheets that boost a signal, set as a twin pair that shares one gas box with fields that point in opposed ways. Its light build, well under one percent of a key length scale, cuts scatter and sharpens track readings.
In 2024 the team ran the tracker in a beam line with muons and pions and tried three gas mixes. Two mixes used helium to suit a planned test that needs slow muons. New read out chips were fitted for the runs. The paper sets out how the data were worked and compares how sharp the tracks were for each gas mix.
Catalog record
| CREATOR | X. Zhao |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 9 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-09587
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The ultra-low material budget GEM-based TPC for tracking with VMM3a readout X. Zhao Abstract The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28% X/X 0 and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a—SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO 2 (70/30 %), He/CO 2 (70/30 %) and He/CO 2 (90/10 %). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented. 1 Introduction Twin-time projection chambers (TWIN TPC) were introduced to track heavy ions in the Super-FRS to cope with an increased particle rate. The conventional TPCs [ 1 ] fitted into the twin TPC used for the amplification stage, a set of four single proportional counters. The strip is read out with delay lines. Even though this concept represented a good choice to cope with high particle rates, the signal length and the low speed of the delay line were the limiting factors. Therefore, to overcome those limitations, the amplification stage was replaced by a Gas Electron Multiplier (GEM) [ 2 ] and the readout by fast and high-density readout electronics, resulting in the GEM-TPC in TWIN configuration concept [ 3 , 4 ] . The second prototype of the four generation of these detectors, named HGB4-2, which stands for Helsinki-GSI-Bratislava, is shown in Fig. 1 and is the subject of the investigation for this work. Figure 1 : The GEM-TPC in twin configuration schematics (left) illustrating the principle of operation. It has two GEM-TPCs, with TPC1 facing the drift to the top and TPC2 to the bottom, inside a single vessel. The HGB4-2 after integrating the VMM3a-SRS during commissioning at the GDD laboratory at CERN (right). This detector has two GEM-TPCs inside a single vessel with the same gas volume. One is rotated 180 degrees in the middle plane with respect to the other. Upstream, the TPC1 has the amplification stage and readout electronics on top, and the second, TPC2, on the bottom. This detector has an ultra-low material budget, which is 0.28% X/X 0 , and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. In this configuration, the electric fields of the two field cages are in opposite directions. As a result, the electrons generated by the traversing particles drift in TPC1 toward the top and in TPC2 to the bottom. The readout plane consists of a single GEM-TPC is 512 strips, with a width of 300 \mu m and, a pitch of 400 \mu m. The total number of strips for the whole detector is 1024 strips. The strips are parallel to the incoming beam direction on both TPCs. The newly integrated continuous readout electronics VMM3a-SRS [ 5 , 6 ] collects the signals of each strip of a single event, digitizes the amplitude, and sets the arrival time stamp. Then, a clustering procedure groups the fired strips of a single event. Recording the signals from a trigger scintillator, which sets the event’s starting time or the t0, makes it possible to reconstruct the coordinates on the vertical plane of a track on both GEM-TPCs. In the horizontal plane, the coordinate is determined by the projection of the cluster in the strip plane. Hence, the two coordinates of the track are found, and the position of the tracks is reconstructed. Section 2 briefly describes the methodology used for the data analysis. Section 3 discusses spatial resolution, the main observable investigated in this work, for different gas mixtures. 2 Experimental Setup The test beam was carried out at the H4 beamline [ 7 ] of the SPS at CERN during the DRD1 test beam in 2024. The main characteristics of the 150GeV/c beam momenta were a wide muon beam and a very narrow one, for pions. The flux was up to 200k particles per spill. The HGB4-2 was located on a mobile platform in front of the RD51 reference tracker [ 8 ] to overlap both sensitive areas and perform a position scan in the entrance window, which is 200 mm in the horizontal plane and 100 mm in the vertical plane for the HGB4-2 and 100 mm in both planes for the RD51 reference tracker. The readout plane of the HGB4-2 is made of strips oriented parallel to the incoming particle beam in 1D, while for the reference tracker, each station has strips in 2D geometry. Figure 2 : Cluster Strip multiplicity of the HGB4-2, for both GEM-TPCs. The mean occupancy is similar for the GEM-TPC Top (in black) and the GEM-TPC Bottom (in red). For this campaign, the gas mixtures used were Ar/CO 2 (70/30 %), He/CO 2 (70/30 %), and He/CO 2 (90/10 %). The helium-based gas mixtures were used to commission the HGB4-2 for the PSI MIXE experiment [ 9 ] . The signals were acquired using the VMM3a-based RD51 scalable readout system. The Front-End chip is the VMM3a ASIC [ 10 ] , which provides the peak amplitude and time at peak for signals crossing a threshold level. The VMM3a Slow Control and Calibration Software [ 11 ] , developed by the RD51 collaboration, was used to control the electronics. For collecting and recording data, tcpdump [ 12 ] was used. For clustering and reconstruction, vmm-sdat [ 13 ] was used. A Python-based analysis was developed for tracking performance analysis. The alignment procedure ensured a good overlap of the detection areas of both systems. The drift velocity was calibrated, yielding a 1 - 2% difference between the GEM-TPC top and bottom. The signal amplitude distribution was measured to assess the level of equalization of their response and to identify the amount of saturated channels. The cluster strip multiplicity obtained agrees with those expected from the computed values of traverse diffusion. Fig. 2 shows the cluster strip multiplicity for the Ar/CO 2 (70/30 %) gas mixture. It can be seen that the two distributions are very similar and the mean occupancy of five strips agrees with the expected traversal diffusion, indicating a very similar response of both GEM-TPCs, to the incoming beam. 3 Spatial resolution for different gas mixtures The main observable under investigation was the