Flux channeling induced nano-confinement and enhancement of microwaves imaged by Rabi oscillation mapping
Jeffrey Rable, Jyotirmay Dwivedi, Nitin Samarth, Paul Stevenson, Arun Bansil, Swastik Kar · 2025
Read Flux channeling induced nano-confinement and enhancement of microwaves imaged by Rabi oscillation mapping by Jeffrey Rable, Jyotirmay Dwivedi, Nitin Samarth, Paul Stevenson, Arun Bansil, Swastik Kar (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-09183.txt.
Introduction
Jeffrey Rable and co-authors show in a 2025 paper a way to squeeze microwaves into tiny spots on a chip. Quantum bits need fine control of radio fields, and mapping those fields at small scales is hard. A wire made of a magnetic alloy does the squeezing here.
The wire channels flux so passing waves pile up in spots under 300 nanometers wide. Power in those spots rose up to 16 times over the base field. A diamond defect sensor mapped the field through its spin swings, with sharp detail. The effect held across a wide power range and left the sensor's key timing trait unharmed. Computer models of the magnet match the maps, which backs use in chip scale radio tools.
Catalog record
| CREATOR | Jeffrey Rable, Jyotirmay Dwivedi, Nitin Samarth, Paul Stevenson, Arun Bansil, Swastik Kar |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 29 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2501-09183
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Flux channeling induced nano-confinement and enhancement of microwaves imaged by Rabi oscillation mapping Jeffrey Rable, Jyotirmay Dwivedi, Nitin Samarth, Paul Stevenson, Arun Bansil, Swastik Kar Abstract With rapid advances in qubit technologies, techniques for localizing, modulating, and measuring RF fields and their impact on qubit performance are of the utmost importance. Here, we demonstrate that flux-channeling from a permalloy nanowire can be used to achieve localized spatial modulation of an RF field and that the modulated field can be mapped with high resolution using the Rabi oscillations of an NV center. Rabi maps reveal ∼ \scriptstyle\mathtt{\sim} 100 mm wavelength microwaves concentrated in sub-300 nm-scale regions with up to ∼ \scriptstyle\mathtt{\sim} 16 × \times power enhancement. This modulation is robust over a 20 dBm power range and has no adverse impact on NV T 2 T_{2} coherence time. Micromagnetic simulations confirm that the modulated field results from the nanowire’s stray field through its constructive/destructive interference with the incident RF field. Our findings provide a new pathway for controlling qubits, amplifying RF signals, and mapping local fields in various on-chip RF technologies. keywords Scanning NV magnetometry, Flux-channeling, Permalloy, Quantum Sensing, Diamond † † email: [email protected] † † affiliation: Corresponding Author † † affiliation: Department of Physics, Northeastern University, Boston, MA 02115 † † affiliation: Quantum Materials and Sensing Institute, Northeastern University, Burlington, MA, 01803 † † affiliation: Department of Physics, Pennsylvania State University, State College, PA, 16802 † † affiliation: Department of Physics, Pennsylvania State University, State College, PA, 16802 † † affiliation: Department of Physics, Northeastern University, Boston, MA 02115 † † affiliation: Quantum Materials and Sensing Institute, Northeastern University, Burlington, MA, 01803 † † affiliation: Department of Physics, Northeastern University, Boston, MA 02115 † † affiliation: Quantum Materials and Sensing Institute, Northeastern University, Burlington, MA, 01803 † † affiliation: Department of Physics, Northeastern University, Boston, MA 02115 † † affiliation: Quantum Materials and Sensing Institute, Northeastern University, Burlington, MA, 01803 † † affiliation: Department of Chemical Engineering, Northeastern University, Boston, MA 02115 † † email: [email protected] † † affiliation: Corresponding Author † † abbreviations: NV,SNVM,Py,RF,MW,FMR,PL † † suppinfo: The advent of practical quantum technologies has the potential to revolutionize fields ranging from computing to biosensing and spintronics. However, as these technologies evolve beyond the proof-of-concept stage, scalable new hardware capable of generating large, localized GHz-frequency microwave magnetic fields to control the underlying qubits are required. The simple approach to driving spin dynamics - using Oersted fields generated by a microwave antenna - requires high power levels to produce sizable field amplitudes and their nonlocal nature becomes problematic in the nanoscale regime. Ferromagnetic dynamics have also been used to control Nitrogen-Vacancy (NV) spin defects in diamond, relying on coupling to magnons Andrich et al. 2017 ; Wang et al. 2020 ; Candido et al. 2020 ; Fukami et al. 2021 ; Simon et al. 2022 ; Trifunovic et al. 2015 and proximal magnetic textures Wolf et al. 2016 . However, magnon-based techniques require tuning of magnetic fields to bring the NV transitions into resonance with magnon modes, while the latter approach suffers from problems associated with undesirable texture dynamics Badea et al. 2018 ; Badea et al. 2023 . Flux channeling via soft ferromagnets offers a promising alternative for increasing local field amplitudes. It is largely unexplored in the nanoscale and GHz regimes, although it has been used in NV center-based sensing of macroscopic, DC-kHz fields Xie et al. 2023 ; Fescenko et al. 2020 and in the engineering of mesoscopic transformers Yun et al. 2004 ; El-Ghazaly et al. 2017 ; Kerner et al. 2004 . Local amplification of fields in flux-channeling occurs when the relative permeability of a ferromagnetic material exceeds unity; this occurs up to the ferromagnetic resonance (FMR) frequency of the material, which can be increased via patterning El-Ghazaly et al. 2017 . The NV center, being a point defect, has a spatial resolution only limited by the NV-sample distance in a scanning system. It can be used to perform measurements from the kHz to GHz range with extremely high sensitivity Casola et al. 2018 ; Broadway et al. 2020 , down to 100’s of nT/\sqrt{Hz} Appel et al. 2015 for resonant microwave fields, which makes the technique ideal for characterizing efficiency and losses in nanoscale RF devices. Unlike lower resolution techniques, scanning NV can probe the sources of loss, such as the localized losses driven by magnetic texture dynamics. Moreoever, the NV qubit allows the characterization of both the fields emitted by the RF devices and the impact the devices could have on the coherence of the defect spin, which are both valuable attributes for translation to applications in quantum information science. Here, we demonstrate the use of magnetic flux channeling in a 20 nm thick Permalloy (Ni-Fe alloy) soft ferromagnetic nanowire to locally modulate a microwave field at an NV center and show how spin state control can be enhanced in this way. For this purpose, we measured Rabi oscillations in a scanning NV magnetometer (SNVM), where the measured Rabi frequency varies linearly with the amplitude of the microwave driving field. A quantitative map of the field modulation is thus obtained such that \Omega_{R}=\gamma_{\text{NV}}B_{\text{MW}} , where \Omega_{R} is the Rabi frequency, \gamma_{\text{NV}} is the NV center’s gyromagnetic ratio, and B_{\text{MW}} is the amplitude of the driving field perpendicular to the NV center’s quantization axis Appel et al. 2015 . Even at 84 nm sample-NV separation, we found maximum field enhancement to be 2.35 \times , which corresponds to a 6-fold reduction in the needed microwave driving power at the highest power tested. In principle, this enhancement could be further improved through a reduction in the NV-sample distance and optimization of both the nanowire geometry and the microwave driving setup. Figure 1: A schematic of the experimental setup showcasing the measurement apparatus and pulse sequences. (a) Our scanning NV magnetometer positioned over our samples. A diamond scanning-probe tip is rastered across the sample, a 515 nm laser is used to polarize and read-out the NV spin state, and a gold wire loop acts as a microwave (MW) antenna to manipulate the spin. (b) Pulse sequences for ODMR and Rabi oscillation measurements. In the ODMR measurement, the MW frequency is swept while the 515 nm laser illuminates the diamond and the resulting photoluminescence (PL) is collected; the PL decreases when the NV \ket{0}\rightarrow\ket{1} transition is driven by the microwave antenna. In a Rabi oscillation measurement, the spin is polarized into the \ket{0} state using a 515 nm laser, and then a resonant microwave field driving the \ket{0}\rightarrow\ket{1} transition is applied for a variable period of time \tau . Afterwards, the photoluminescence is read out, and a reference measurement without microwaves is done to measure the fluorescence of the brighter \ket{0} state. This results is an optical contrast, given by the measured signal divided by the reference, which allows us to determine the spin state. Fig. 1 provides a schematic of our experimental setup and measurement schemes. Flux channels were engineered using lithographically patterned semicircular (350 nm wide, 20 nm thick) Permalloy nanowires on a silicon substrate. The nanowires have a 5 µm diameter and a central, 140 nm wide half-circle notch defect. These wires are good candidates