Progress in Chromatic Calorimetry Concept: Improved Techniques for Energy Resolution and Particle Discrimination

Devanshi Arora, Matteo Salomoni, Yacine Haddad, Vojtech Zabloudil, Michael Doser, Masaki Owari, Etiennette Auffray · 2025

Read Progress in Chromatic Calorimetry Concept: Improved Techniques for Energy Resolution and Particle Discrimination by Devanshi Arora, Matteo Salomoni, Yacine Haddad, Vojtech Zabloudil, Michael Doser, Masaki Owari, Etiennette Auffray (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-08483.txt.

Introduction

Devanshi Arora and co-authors present a 2025 update on a color coded way to weigh particle energy. In a standard calorimeter, a particle shower is caught as one blur. Their stack layers glow materials that shine at set colors, so the shower's depth growth can be read by hue.

Beams of electrons and pions up to 100 giga electron volts tested the stack. The layered colors split the two particle kinds better and traced shower shapes in fine steps. Energy reads sharpened as well. The team frames the method as a route to finer particle ID in high energy physics. Next steps may add quantum dot layers to push the color split further.

Catalog record

CREATORDevanshi Arora, Matteo Salomoni, Yacine Haddad, Vojtech Zabloudil, Michael Doser, Masaki Owari, Etiennette Auffray
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE26 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-08483

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Progress in Chromatic Calorimetry Concept: Improved Techniques for Energy Resolution and Particle Discrimination Devanshi Arora, Matteo Salomoni, Yacine Haddad, Vojtech Zabloudil, Michael Doser, Masaki Owari, Etiennette Auffray Abstract This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle interactions at different shower depths through wavelength-based discrimination. Our experimental validation of this novel method utilizes an arrangement of scintillator materials to improve energy resolution and particle identification. The stacking arrangement of scintillators is organized by their emission wavelengths to track the development of electromagnetic and hadronic showers. By testing electrons and pions with energies up to 100 GeV, the setup demonstrated better discrimination and provided detailed measurements of shower profiles. The results indicate that our experimental validation significantly aims to enhance particle identification and energy resolution, highlighting its potential value in high-energy particle detection. Future work will explore the integration of Quantum Dots (QD) technology to advance these capabilities in chromatic calorimetry further. 1 Introduction In particle physics, calorimeters are essential instruments used to measure the energy of particles as they interact with detector materials. They play a critical role in particle accelerator experiments, where understanding fundamental particle properties is vital. Homogeneous calorimeters use a single material for energy absorption and signal detection, allowing them to achieve excellent energy resolution [ 1 ] . Common materials, such as lead tungstate (PbWO4) are favored for their scintillation properties and high density, with PbWO4 being notably employed in the electromagnetic calorimeters of both the CMS and ALICE experiments at LHC, CERN [ 2 , 3 ] . However, the homogenous calorimeters often lack longitudinal segmentation, which makes it difficult to capture detailed profiles of particle showers as they develop. Understanding the longitudinal development of these showers is crucial for accurately identifying particles and studying their interactions. When a high-energy particle interacts with matter, it produces secondary particles that create a cascade known as a shower. An ideal homogeneous calorimeter accurately measures and reconstructs the shower, allowing it to determine the original energy and type of the incoming particle. However, without longitudinal segmentation, discerning subtle differences in shower profiles becomes challenging. This highlights the need for continued advancements in calorimeter technology to improve particle identification and enhance our understanding of fundamental interactions in high-energy physics experiments [ 4 ] . To overcome the limitations of longitudinal segmentation, chromatic calorimetry is introduced by M.Doser et al. [ 5 ] , which utilizes varying scintillator materials to differentiate between different wavelengths of emitted light, offering a potential solution to the limitations of homogeneous calorimeters. This concept takes advantage of the tunability and narrow emission bandwidth (approximately 20 nm) of various materials, such as quantum dots, and quantum wells [ 6 , 7 ] . By layering scintillator materials with different emission wavelengths, we aim to enhance the measurement of energy deposited by particles during their interactions. Our previous test beam study validates this proposed concept using inorganic scintillators strategically stacked by decreasing emission wavelength. Using a 100 GeV beam, we achieved analytical discrimination between electron and pion events and the reconstructed energy signals also reveal valuable separability between hadronic and electromagnetic interactions at higher energies, enhancing our ability to differentiate between these events [ arora2024enhancingenergyresolutionparticle ] . To enhance energy resolution, improve particle identification, and better track the development of electromagnetic and hadronic showers, this paper presents a modified iteration of the previously conducted chromatic calorimetry experiment with a new arrangement of scintillator materials. We conducted tests using electrons and pions with energies up to 100 GeV, demonstrating improved discrimination and providing detailed measurements of shower profiles. The results indicate that this modified design significantly enhances particle identification and energy resolution, underscoring its potential value in high-energy particle detection. However, it is important to note that our current experimental iterations do not incorporate quantum dots. Instead, we focus on optimizing the arrangement of scintillator materials to enhance particle identification and energy resolution in our chromatic calorimetry setup. Looking ahead, the ultimate goal of this research is to develop a quantum dot-based chromatic calorimeter that utilizes the unique properties of quantum dots for even greater performance in future applications. This will allow for more precise measurements and better integration within detection systems. In this paper, we investigate an experiment to validate the chromatic calorimetry concept which was initially introduced by M. Doser et al. [ 5 ] . We have designed a crystal stack with scintillators having different emission wavelengths, which was subjected to to high energy beam of 100 GeV. 2 Materials and methods 2.1 Crystal stack description The crystal stack was constructed using the following scintillators, shown in Fig. 1 (with the last dimension along the longitudinal shower propagation): 2x2x2 cm 3 gadolinium aluminum gallium garnet (GAGG, 540 nm peak emission), 2x2x5 cm 3 and 2x2x12 cm 3 lead fluoride (PbF 2 , Cherenkov emitter), 2x2x2 cm 3 EJ262 (plastic scintillator, 481 nm peak emission), and 2x2x2 cm 3 EJ228 (plastic scintillator, 391 nm peak emission). These plastic scintillators were purchased from Scionix Holland B.V. [ 8 ] . This arrangement was designed to capture scintillation light from three scintillators: at the beginning of the shower (in GAGG), at the shower maximum (in EJ262), and the end of the shower (in EJ228). PbF 2 crystals, chosen for their high density and transparency to the emission wavelengths of the other scintillators, were incorporated within the stack to facilitate shower development between GAGG, EJ262, and EJ228. PbF 2 crystals have short Radiation Length, Moliere Radius, high stopping power, and relatively low Cherenkov emission [ 9 ] . The order of the scintillators along the shower propagation was carefully optimized to minimize re-absorption effects and ensure efficient photon transmission through the stack. A long-pass filter (LPF) FELH0550, was added after GAGG to ensure that light emitted from GAGG is well-separated from other scintillators. The experimental setup was completed with a Hamamatsu Multi-anode Photo Multiplier Tube (MaPMT) readout system [ 10 ] , which selected the emission characteristics of light emitted at different shower depths using Optical Filters (OPF), one per scintillator emission, placed in front of three of the four photocathodes of the PMT. The fourth photocathode was equipped with a 420 nm bandpass filter (BPF), which was chosen to avoid interference with the emission characteristics of the other scintillator materials. We evaluated the photon yield across all output channels through test beam data analysis. These evaluations provide critical insights into the chromatic calorimeter’s performance and the dynamics of electromagnetic showers. Our study focuses on distinguishing between electrons and pions, profiling the shower along its full length, and particle identification through pulse shape analysis. These findings underscore the importance of making precise adjustments in detector design to enhance the accuracy of chromatic reconstruction. Figure 1 : Chromatic calorimeter module schematic: The module comprises scintillators, one Thorlabs long pass FELH0550 (LPF) placed after GAGG, and read out by a MaPMT with four channels. Four different OPF are used, where for three channels of the MaPMT: Thorlabs long pass FELH0550 for GAGG, short pass FESH0400 for EJ228, and bandpass FB475-10 for EJ262, and the fourth channel a 420 nm bandpass filter

Read the complete text