Dual readout with capillary tubes – status and prospects

\firstname Nicolò \lastname Valle \fnsep · 2025

Read Dual readout with capillary tubes – status and prospects by \firstname Nicolò \lastname Valle \fnsep (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2501-00479.txt.

Introduction

Nicolo Valle reports on a new kind of particle detector in a 2025 paper. The device is a calorimeter, which measures the energy of particle showers, and it reads each shower two ways at once. Twin reads let physicists sort the shower's parts and sharpen the energy call.

Valle walks through the current fiber-based test units, with fibers packed in fine tubes. A new high-resolution, finely grained demonstrator, called HiDRa, gets a full account of its build and assembly. Simulation results round out the picture, along with the beam tests planned to prove the design in real particle fire.

Catalog record

CREATOR\firstname Nicolò \lastname Valle \fnsep
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE16 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2501-00479

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Dual readout with capillary tubes – status and prospects \firstname Nicolò \lastname Valle \fnsep Abstract This paper discusses the ongoing development and testing of dual-readout fiber-based calorimeter demonstrators. An overview of the existing prototype will be presented, along with details on the assembly and integration strategies of the High-Resolution Highly-Granular Dual-Readout Demonstrator (HiDRa). A concise yet informative summary of simulation results and a perspective on upcoming beam tests will be discussed. 1 Introduction The advancement of high-energy physics experiments, particularly after the LHC era, relies on the development of sophisticated detectors capable of precise measurements. Proposed future projects such as the Future Circular Collider (FCC) and the Circular Electron-Positron Collider (CEPC) aim to exploit the benefits of electron-positron collisions for high-precision studies of electroweak, Higgs and flavor physics. A critical aspect of these studies is the accurate measurement of hadronic jets which requires advanced calorimetry techniques targeting resolution as good as 30\%/\sqrt{E} . The dual-readout method has emerged as a promising technique for improving hadron energy reconstruction and has already demonstrated reliability and advancements over the last decades DREAM ; ART . This method involves the simultaneous measurement of signals from scintillating and Čherenkov light produced in the shower development, thereby correcting for the electromagnetic fraction of hadron showers on an event-by-event basis. Further improvements have been reached in the latest R&D developments with the the integration of compact photosensors (Silicon Photomultipliers, SiPMs). This permits fine segmentation, enabling sophisticated event reconstruction through particle-flow and machine learning algorithms. Different dual-readout calorimetry projects are currently under development; in this paper the technology exploiting fiber light collection, with fibers embedded in capillary tubes, will be presented. The concept behind the design of a scalable and cost-affordable solution will be discussed, focusing on the activities ongoing to build a demonstrator with a large hadronic-shower containment and the expected performance in a real scenario. 2 The electromagnetic-shower prototype In 2021, the first demonstrator designed to validate the feasibility of single fiber readout with SiPMs in a dual-readout calorimeter was assembled. This demonstrator utilizes brass capillary tubes (63% Cu, 37% Zn), arranged in a honeycomb geometry and hosting alternating rows of doped (scintillating) and clear optical plastic fibers, which are responsible for collecting Čherenkov light. The capillaries have an outer diameter of 2\,\mathrm{mm} and an inner diameter of 1.1\,\mathrm{mm} , resulting in approximately 63\% absorber material by volume, including the gaps between capillaries. The prototype, designed to contain electron-induced showers, features a frontal surface area of 100\,\mathrm{cm}^{2} and a length of 100\ \mathrm{cm} . It employs a modular geometry, with the capillaries organized into 9 towers, each containing 320 tubes. The layout of the detector, its modules, and the fibers are illustrated in Figure 1 . Figure 1: Layout of the brass capillaries demonstrator assembled in 2021. The layout of the alternating rows of clear and scintillating fibers loaded in each of the 9 modules can be appreciated in the middle inset. The readout approach features a hybrid solution with both Photomultiplier Tubes (PMTs) and SiPMs. Due to the dimensional constraints of the SiPM package at the time of construction, fibers from the central tower are routed to an interface board at the back of the calorimeter, used for an easier connection to the front-end boards. Each fiber of the central module, both scintillating and Čherenkov , is individually connected to a Hamamatsu S14160-1315PS SiPM, with a photosensitive area of 1.3\times 1.3\,\mathrm{mm}^{2} and 15\,\mathrm{\mu m} pitch, ensuring a proper dynamic range ROMUALDO . The peripheral modules, labeled M1 to M8 in the figure, are each equipped with two PMTs. Each of them collects photons from all scintillating and Čherenkov fibers within the module, respectively. A yellow filter is placed at the end of the scintillating fibers to filter out shorter-wavelength components of the spectrum, in order to mitigate the effect of the attenuation length within the plastic material and reduce the signal’s dependency on the starting point of the shower. 2.1 Testing on the beam The prototype has been tested with positron beams at the DESY laboratories in Germany in 2021, and then at the CERN SPS in 2021 and 2023. Highlights from the 2021 testing campaign are summarized in the following, while all the details can be found in TB2021 . Figure 2: Beam line setup for 2021 measurements at CERN SPS (not-to-scale). Taken from TB2021 . The test beam setup is schematized in Figure 2 . It includes two Čherenkov counters for positron selection, Delay Wire Chambers (DWCs) to estimate the impact point on the calorimeter, scintillator plates for triggering and muon selection, and finally a lead-scintillator preshower detector (PS) for the identification of high-energy positrons. The calorimeter exhibited a good response, reconstructing the true beam energy within 1\% across the entire energy range of 10-120 GeV. However, energy resolution estimates were limited up to 30 GeV, due to shower containment issues caused by the placement of the PS detector. Installation constraints within the experimental area meant that the PS could only be positioned 285 cm from the face of the calorimeter, resulting in an increased leakage and a worsened resolution. At lower energies, a sufficient hadron rejection could be achieved using the upstream Čherenkov counters, permitting the removal of the PS. The calorimeter’s resolution, evaluated as the ratio of the RMS width to the mean value of a Gaussian fit to the energy measurement distribution, is illustrated in Figure 3 for both experimental data and simulation. In ref TB2021 a detailed study can be found on the dependence of the calibrated signal from the impact point position of the beam. A periodic modulation in the y coordinate has been identified, corresponding to the spacing between different fibers, with a smaller amplitude observed in the Čherenkov signal due to the correlation between the direction of the emitted light and the electron’s trajectory. Such a modulation is influenced by the number of fibers sampling the shower, therefore by the angle of tilt between the fibers and the beam line. A tilt angle of 2.5^{\circ} was found to effectively mitigate this effect. For this reason, the resolution measured in simulations at this tilt angle is also presented in Figure 3 , demonstrating a reduction in the stochastic term from (17.5\pm 2.2)\%/\sqrt{E} , measured on the test beam, to 14.5\%/\sqrt{E} . Figure 3: Measured energy resolution. Data points (black) are available only for E<30 GeV, and are compared with simulation including the full beam setup (blue). Red points correspond to data simulated by tilting the calorimeter by an angle of 2.5^{\circ} (see text). Taken from TB2021 . Despite the challenges and experimental constraints, key measurements were achieved, including a comprehensive validation of the Geant4 simulation used to reproduce the calorimeter geometry and the entire beam setup. Figure 4 shows the lateral profile of showers produced by 20 GeV positrons in the central tower. The implementation of single fiber readout with SiPMs enabled an unprecedented millimeter-level sampling of the shower development. This high degree of accuracy in reproducing the shower profile at such a fine resolution scale is a further proof of the effectiveness of Geant4 simulations in guiding the design and optimization of future detectors. Figure 4: Fraction of energy deposited in a fiber as a function

Read the complete text