UNISEP: A Unified Sensor Placement Framework for Human Motion Capture and Wearables

Julius Welzel, Sein Jeung, Lara Godbersen, Seyed Yahya Shirazi · 2024

Read UNISEP: A Unified Sensor Placement Framework for Human Motion Capture and Wearables by Julius Welzel, Sein Jeung, Lara Godbersen, Seyed Yahya Shirazi (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-21159.txt.

Description

Abstract The proliferation of wearable sensors and monitoring technologies has created a need for standardized sensor placement protocols. While existing standards like the Surface Electromyography for Non-Invasive Assessment of Muscles (SENIAM) recommendations for electromyography (EMG) and the 10–20 system for electroencephalography (EEG) address modality-specific applications, no comprehensive framework spans different sensing modalities and applications.

Catalog record

CREATORJulius Welzel, Sein Jeung, Lara Godbersen, Seyed Yahya Shirazi
YEAR2024
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2412-21159

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

UNISEP: A Unified Sensor Placement Framework for Human Motion Capture and Wearables Julius Welzel, Sein Jeung, Lara Godbersen, Seyed Yahya Shirazi Abstract The proliferation of wearable sensors and monitoring technologies has created a need for standardized sensor placement protocols. While existing standards like the Surface Electromyography for Non-Invasive Assessment of Muscles (SENIAM) recommendations for electromyography (EMG) and the 10–20 system for electroencephalography (EEG) address modality-specific applications, no comprehensive framework spans different sensing modalities and applications. We present the Unified Sensor Placement (UNISEP) framework to facilitate reproducible handling of human movement and physiological data across various systems and research domains. The framework provides a method to describe coordinate systems and placement protocols based on anatomical landmarks, and is designed to complement existing data-sharing standards such as the Brain Imaging Data Structure (BIDS) and Hierarchical Event Descriptors (HED). Even during its proposal stage, the UNISEP approach has been adopted by the EMG-BIDS extension (BIDS version 1.11.0), confirming the community need for a unified, machine-readable sensor placement framework. The UNISEP framework facilitates consistency, reproducibility, and interoperability in applications ranging from lab-based clinical biomechanics to continuous health monitoring in everyday life. Keywords: sensor placement, standardization, wearable sensors, motion capture, anatomical landmarks, coordinate systems, BIDS, reproducibility, FAIR data 1 Introduction Measurement of human movement and physiological signals is fundamental in fields ranging from biomechanics to psychology. It is also instrumental in clinical rehabilitation and continuous health monitoring [ 1 , 2 ] . Technological advancements in motion capture systems, inertial sensors, and wearable devices have expanded data acquisition and analysis opportunities that reach far beyond traditional laboratory applications. Since the placement of body-worn sensors has a significant effect on acquired signals, a standardization routine for sensor placement practices is essential. A standardized protocol is of utmost importance to improve data consistency, interpretability, reproducibility, and interoperability across diverse applications [ 2 , 3 , 4 , 5 , 6 ] . The impact of sensor placement on data quality is well-documented. In the field of biomechanics, studies have shown that even small changes in sensor positioning can significantly affect measurements and their outcomes. In electromyography (EMG), electrode placement variations relative to the target muscle can lead to signal amplitude changes of up to 50% and altered muscle activation patterns [ 7 , 8 ] . Similar effects have been observed with inertial measurement units (IMUs), where variations in placement and orientation can substantially impact acceleration and angular velocity measurements during dynamic movements [ 9 ] . The same problem applies to optical motion capture applications; the deviation of markers from predefined positions can affect downstream kinematic estimates [ 10 ] . Accuracy of sensor placement affects data quality across body-worn measurement modalities. In the measurement of biopotentials, such as electrocardiography (ECG), EMG, and electroencephalography (EEG), electrode positioning directly affects waveform morphology and measurement accuracy, with small deviations potentially leading to misinterpretation [ 11 , 12 , 13 ] . The same principle applies to IMU-based systems, continuous monitoring devices, and emerging wearable technologies where sensor location relative to the underlying anatomy determines data quality. Several modality-specific standards address sensor placement within their respective domains. The Surface Electromyography for Non-Invasive Assessment of Muscles (SENIAM) recommendations provide guidelines for surface EMG electrode placement on specific muscles, including recommended positions, electrode sizes, and inter-electrode distances [ 14 ] . The Mason-Likar configuration specifies electrode positions for exercise ECG monitoring [ 15 , 16 ] . In EEG, the international 10–20 system [ 17 ] and the extended 5–10 system [ 18 ] provide standardized electrode placement to ensure reproducibility and anatomical relevance. Yet, these standards are modality-specific and typically require expertise for correct application. This highlights a critical gap: while existing standards address specific biosignal modalities, a more comprehensive and application-agnostic framework suited for including various sensors does not exist. Moreover, current standards leave room for improvement [ 19 , 20 ] , to incorporate a wider user base with varying levels of expertise in anatomy, biomechanics, and biosensors. At the same time, large-scale data-sharing initiatives and machine-learning techniques in health monitoring and movement analysis require a comprehensive sensor placement framework. These applications require consistent and well-documented data collection protocols for meaningful comparisons and reliable results. Current data-sharing standards like the Brain Imaging Data Structure (BIDS) [ 21 ] and the Hierarchical Event Descriptors (HED) [ 22 ] provide robust frameworks for data organization but do not include guidelines for sensor placement across multiple types of human monitoring applications. Critically, such data standards require machine-readable metadata describing sensor positions, as conveying this information through visual documentation alone is impractical for an automated workflow. Here, we propose the Unified Sensor Placement (UNISEP) framework addressing these challenges through a comprehensive system of anatomical landmarks, coordinate systems, and placement protocols. UNISEP defines anatomical coordinate systems for body segments based on established landmarks [ 1 , 23 ] and establishes a hierarchical system for different measurement contexts. UNISEP is technology-agnostic, accommodating various sensing modalities while maintaining compatibility with existing data-sharing standards, allowing existing records to be annotated with the proposed framework (see examples of motion capture and IMU sensor placement online ). The following sections detail the proposed framework, beginning with fundamental definitions and proceeding to specific placement protocols for different body segments with recommendations for implementation and validation. 2 The UNISEP Framework 2.1 Anatomical Coordinate Systems The foundation of the UNISEP framework rests on the use of established anatomical landmarks and spatial references to describe Cartesian coordinate systems. These definitions enable consistent interpretation and implementation across different applications and laboratories. A coordinate system consists of an origin point and a set of axes that define directions in space. In human movement analysis, we encounter multiple coordinate systems: the global laboratory system, anatomical systems tied to body segments, and sensor- or device-specific systems. The relationships between these systems must be clearly defined to ensure meaningful data interpretation. These practices are consistent with the International Society of Biomechanics (ISB) recommendations for standardization of kinematic data reporting, which emphasize clear definitions of anatomical and global coordinate systems [ 24 , 25 ] . The anatomical coordinate system for each body segment is defined using palpable landmarks that can be reliably identified across individuals. These landmarks, drawn from established anatomical references (see Section 2.2 and Appendix A), are used to define the coordinate system of a body segment and to provide spatial reference for sensor placement. The framework defines each coordinate system through: 1. An origin point based on specific anatomical landmarks. 2. Primary axes aligned with functional anatomical directions. 3. Clear definitions of positive directions and measurement dimensions (e.g., percent of segment length, millimeters). The framework defines sensor placement locations using local anatomical coordinate systems. These local systems are part of a larger kinematic chain, consistent with practices in biomechanics and robotics where transformations between local and global coordinate systems are computed through forward kinematics [ 1 ] . Although the framework focuses on local definitions, users can derive global coordinates through standard transformation techniques if needed. 2.2 Anatomical Landmark System The framework uses a set of anatomical landmarks drawn from established anatomical and biomechanical references [ 1 , 24 , 25 ] . The landmarks were selected for their reliability, accessibility across different body

Read the complete text