Rotating polarization magnetometry
Szymon Pustelny, Przemysław Włodarczyk · 2024
Read Rotating polarization magnetometry by Szymon Pustelny, Przemysław Włodarczyk (2024) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2412-20044.txt.
Introduction
Szymon Pustelny and Przemysław Włodarczyk present a new way to measure magnetic fields with light and atoms, using light whose plane of swing turns without pause. Fine measures of this kind serve many fields of science and tech, but a known method loses sharpness at higher fields.
The pair show that the turning light gives a strong signal and keeps high sharpness over a range near three times the field of Earth itself. It beats older forms that blink the light on and off. Their results also cast doubt on the old claim that a shift from alignment to orientation caused the loss at high fields.
Catalog record
| CREATOR | Szymon Pustelny, Przemysław Włodarczyk |
|---|---|
| YEAR | 2024 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2412-20044
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Rotating polarization magnetometry Szymon Pustelny, Przemysław Włodarczyk Abstract Precise magnetometry is vital in numerous scientific and technological applications. At the forefront of sensitivity, optical atomic magnetometry, particularly techniques utilizing nonlinear magneto-optical rotation (NMOR), enables ultraprecise measurements across a broad field range. Despite their potential, these techniques reportedly lose sensitivity at higher magnetic fields, which is attributed to the alignment-to-orientation conversion (AOC) process. In our study, we utilize light with continuously rotating linear polarization to avoid AOC, producing robust optical signals and achieving high magnetometric sensitivity over a dynamic range nearly three times greater than Earth’s magnetic field. We demonstrate that employing rotating polarization surpasses other NMOR techniques that use modulated light. Our findings also indicate that the previously observed signal deterioration is not due to AOC, suggesting an alternative cause for this decline. I Introduction Optical magnetometry belongs to one of the most mature quantum technologies to date Budker and Romalis 2007 ; Budker and Jackson Kimball 2013 ; Budker et al. 2000a ; Allred et al. 2002 ; Alexandrov 2003 ; Seltzer et al. 2007 ; Groeger et al. 2006 ; Pustelny et al. 2008 ; Kim and Savukov 2016 ; Colombo et al. 2016 ; Oelsner et al. 2019 ; Bevington et al. 2019 ; Wang et al. 2020 ; Fang et al. 2020 . Modern optical atomic magnetometers (OAMs) offer a magnetic-field sensitivity often exceeding 10 fT/Hz 1/2 , with the only sensitivity-wise competitors being bulky and high-maintenance superconducting quantum interference devices (SQUIDs). This remarkable sensitivity, combined with technical simplicity and low operating costs, has led to a wide range of applications, from biomagnetic field measurements Bison et al. 2003 ; Murzin et al. 2020 ; Brookes et al. 2022 and surveys natural resources Lu et al. 2023 ; Akulshin et al. 2025 to zero-field nuclear magnetic resonance detection Bevilacqua et al. 2016 ; Tayler et al. 2017 ; Barskiy et al. 2025 and searches for ultra-light dark matter Pustelny et al. 2013 ; Jiang et al. 2021 ; Terrano and Romalis 2021 ; Afach et al. 2024 ; Bloch and Kalia 2024 (for more information, see, for example, Ref. Budker and Jackson Kimball 2013 and references therein). The highest sensitivity of OAMs is achievable at very weak magnetic fields, necessitating effective shielding against external and uncontrolled magnetic fields. Operation at stronger fields, such as Earth’s magnetic field, requires the implementation of solutions that can, at least partially, capitalize on the low-field sensitivity. For example, the stronger field could be compensated using a set of calibrated magnetic-field coils to bring the operating point of the magnetometer back to zero Seltzer and Romalis 2004 ; Belfi et al. 2007 ; Chu et al. 2014 ; Papoyan et al. 2016 . By actively bringing the field to zero, one can (nominally) maintain the zero-field sensitivity, additionally obtaining directional sensitivity through magnetic-field modulation Seltzer and Romalis 2004 ; Papoyan et al. 2016 . Unfortunately, due to the limited stability of current sources and inhomogeneities induced by compensation of the magnetic fields, these methods still suffers from a sensitivity loss. An alternative technique that has recently regained interest is based on the observation of magnetization decay of optically polarized atomic vapors Limes et al. 2020 ; Wilson et al. 2020 ; Lucivero et al. 2022 ; Zhang et al. 2022 ; Hunter et al. 2023 . By analyzing a time-dependent signal arising after the pulsed polarization of the atoms, one determines the spin precession frequency and hence the magnetic field to which the atoms are exposed to. Despite its utility, this approach does have some drawbacks, including (in some cases) the relatively involved signal analysis and inability to perform continuous measurements. The third group of methods is based on modulating certain physical parameters of the system to enhance sensitivity in high fields. A notable example of this approach is the so-called M x magnetometry Alexandrov et al. 1996 ; Groeger et al. 2006 ; Scholtes et al. 2016 , which is based on the application of an external, oscillating magnetic field and observation of light transmission through the magneto-optically active medium. By an appropriate choice of the oscillating-field frequency, one can resonantly excite spin precession, generating the strongest dynamic response of the medium. In turn, by tracking the resonance position, one can monitor the magnetic-field strength. While in the M x magnetometers the circularly polarized light is typically used, similar measurements can be achieved with linearly polarized light Ledbetter et al. 2007 ; Put et al. 2019a . In this case, one can either detect static or oscillating magnetic fields by controlling the other field frequency or magnitude Put et al. 2019b . The drawback of these techniques, however, is the necessity of applying an external field, which, in the case of multiple sensors, for example, for biomagnetic field imaging Bison et al. 2003 , leads to cross-talk between the devices. Alternatively, the additional field can be replaced by modulation of interacting-light parameters Budker and Jackson Kimball 2013 . This was already demonstrated in the first Bell-Bloom magnetometer Bell and Bloom 1961 , where the pumping light intensity was modulated, giving rise to the so-called high-frequency resonance arising when the modulation frequency coincides with the magnetization-precession (Larmor) frequency of atoms. This technique was further developed in the scope of magnetometric techniques exploring nonlinear magneto-optical rotation (NMOR) Budker et al. 2000a , where both frequency Budker et al. 2002 ; Acosta et al. 2006 and amplitude Gawlik et al. 2006 ; Pustelny et al. 2008 modulation were used to measure stronger magnetic fields. A problematic feature of NMOR magnetometers is the deterioration of the amplitude of high-frequency resonances Acosta et al. 2008 , and hence the magnetic-field sensitivity, with increasing magnetic field. It is known that this deterioration and broadening of the resonance can be attributed to the splitting observed in the NMOR resonance due to the nonlinear Zeeman effect, where resonances associated with different magnetic sublevels are unequally shifted Acosta et al. 2006 ; Chalupczak et al. 2010 . Additionally, it has been postulated that this effect may also originate from the so-called alignment-to-orientation conversion (AOC) Budker et al. 2000b . This effect arises when the electric field of light is not parallel to the atomic polarization and it consists of the transfer of the atomic polarization (alignment) that is detectable in NMOR into atomic polarization (orientation) that is undetectable with the method. It should be noted, however, that the process of AOC conversion arises when there is a non-zero angle between light and atomic polarizations, i.e., it disappears when they are parallel. In this work, we present the application of light with rotating linear polarization for optical magnetometry. By precisely matching the atomic Larmor frequency with the frequency of polarization rotation, we generate dynamic polarization of the medium. This dynamic atomic polarization leads to the polarization rotation of the second initially unmodulated light beam. The parameters of the induced NMOR resonances are measured against factors such as light intensity and tuning. Since, the orientation of atoms and light polarization remains parallel at all times, i.e., AOC does not arise, this arrangement allows us to test the role of the effect in the deterioration of magnetometric sensitivity at higher fields. Specifically,